Feasibility of Newly Developed Endoscopic Ultrasound with Zone Sonography Technology for Diagnosis of Pancreatic Diseases

0

조회

0

다운로드

0

인용

0

참고문헌

초록

Background/Aims: To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonographyTM technology (ZST; Fujifilm Corp.). Methods: Seventyfive patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled,besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. Results: In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49±0.50, 3.65±0.48, respectively. After AASS, A and B scored 4.36±0.48 and 4.40±0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. Conclusions: EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited.

Abstract

Background/Aims: To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonographyTM technology (ZST; Fujifilm Corp.). Methods: Seventyfive patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled,besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. Results: In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49±0.50, 3.65±0.48, respectively. After AASS, A and B scored 4.36±0.48 and 4.40±0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. Conclusions: EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited.

참고문헌 (14)

  1. Uehara H, "Diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration for suspected pancreatic malignancy in relation to the size of lesions", J Gastroenterol Hepatol, 26, pp.1256~1261 (2011)
  2. Fisher L, "Endoscopic ultrasound guided fine needle aspiration of solid pancreatic lesions: performance and outcomes", J Gastroenterol Hepatol, 24, pp.90~96 (2009)
  3. Sakamoto H, "Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses", J Gastroenterol Hepatol, 24, pp.384~390 (2009)
  4. Hirooka Y, "Case of intraductal papillary mucinous tumor in which endosonography-guided fine-needle aspiration biopsy caused dissemination", J Gastroenterol Hepatol, 18, pp.1323~1324 (2003)
  5. Hirooka Y, "Diagnosis of pancreatic disorders using contrast-enhanced endoscopic ultrasonography and endoscopic elastography", Clin Gastroenterol Hepatol, 7(11 Suppl), pp.S63~S67 (2009)
  6. Hirooka Y, "Clinical oncology for pancreatic and biliary cancers: advances and current limitations", World J Clin Oncol, 2, pp.217~224 (2011)
  7. Niwa K, "Preclinical study of endoscopic ultrasonography with electronic radial scanning echoendoscope", J Gastroenterol Hepatol, 18, pp.828~835 (2003)
  8. Ishikawa H, "A comparison of image quality between tissue harmonic imaging and fundamental imaging with an electronic radial scanning echoendoscope in the diagnosis of pancreatic diseases", Gastrointest Endosc, 57, pp.931~936 (2003)
  9. Niwa K, "Comparison of image quality between electronic and mechanical radial scanning echoendoscopes in pancreatic diseases", J Gastroenterol Hepatol, 19, pp.454~459 (2004)
  10. Napolitano D, "Sound speed correction in ultrasound imaging", Ultrasonics, (44 Suppl 1), pp.e43~e46 (2006)
  11. Boozari B, "Evaluation of sound speed for detection of liver fibrosis: prospective comparison with transient dynamic elastography and histology", J Ultrasound Med, 29, pp.1581~1588 (2010)
  12. Weiwad W, "Direct in-vitro measurement of ultrasound velocity in carcinomas, mastopathic tissue, fatty tissue and fibroadenomas of the female breast", Rofo, 171, pp.480~484 (1999)
  13. Sehgal CM, "Quantitative relationship between tissue composition and scattering of ultrasound", J Acoust Soc Am, 94, pp.1944~1952 (1993)
  14. Errabolu RL, "Dependence of ultrasonic nonlinear parameter B", A on fat, 1987, pp.9, 180~194

관련 논문AI추천

이 간행물의 다른 논문 (19건)