Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is the go-to method for obtaining samplesfrom gastrointestinal tract and pancreatic lesions. When the transduodenal approach is utilized, the use of a more flexible needle,such as a nitinol 19-gauge (G) needle, has been recommended. The aim of this study was to evaluate the feasibility and accuracy of19-G flexible aspiration needles in obtaining samples from solid lesions through a transduodenal approach. Methods: This was a retrospective analysis of prospectively collected data from eight Italian endoscopy centers. Consecutive patientswith solid lesions who underwent transduodenal EUS-FNA with a 19-G flexible needle were included. Results: A total of 201 patients were enrolled. According to histology, EUS, radiology and 12 months of follow-up, 151 patientshad malignant lesions and 50 patients had benign lesions. EUS-FNA was feasible in all cases. An adequate histologic sample wasobtained in all except eight cases (96.1%). The sensitivity of EUS-FNA was 92.1% (95% confidence interval [CI], 86.8%–95.7%), andthe specificity was 100% (95% CI, 90.5%–100%). The positive predictive value was 100% (95% CI, 93.4%–100%), and the negativepredictive value was 74% (95% CI, 62.8%–82.7%). The diagnostic accuracy was 93.5% (95% CI, 89.2%–96.5%). Conclusions: The transduodenal approach for obtaining samples from solid lesions using a 19-G flexible needle seems feasible andaccurate.
Abstract
Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is the go-to method for obtaining samplesfrom gastrointestinal tract and pancreatic lesions. When the transduodenal approach is utilized, the use of a more flexible needle,such as a nitinol 19-gauge (G) needle, has been recommended. The aim of this study was to evaluate the feasibility and accuracy of19-G flexible aspiration needles in obtaining samples from solid lesions through a transduodenal approach. Methods: This was a retrospective analysis of prospectively collected data from eight Italian endoscopy centers. Consecutive patientswith solid lesions who underwent transduodenal EUS-FNA with a 19-G flexible needle were included. Results: A total of 201 patients were enrolled. According to histology, EUS, radiology and 12 months of follow-up, 151 patientshad malignant lesions and 50 patients had benign lesions. EUS-FNA was feasible in all cases. An adequate histologic sample wasobtained in all except eight cases (96.1%). The sensitivity of EUS-FNA was 92.1% (95% confidence interval [CI], 86.8%–95.7%), andthe specificity was 100% (95% CI, 90.5%–100%). The positive predictive value was 100% (95% CI, 93.4%–100%), and the negativepredictive value was 74% (95% CI, 62.8%–82.7%). The diagnostic accuracy was 93.5% (95% CI, 89.2%–96.5%). Conclusions: The transduodenal approach for obtaining samples from solid lesions using a 19-G flexible needle seems feasible andaccurate.
참고문헌 (21)
- Polkowski M, "Technical aspects of endoscopic ultrasound(EUS)-guided sampling in gastroenterology : European Society of Gastrointestinal Endoscopy(ESGE)technical guideline-March 2017", Endoscopy, 49, pp.989~1006 (2017)
- DeWitt J, "Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles : a multicenter, prospective, randomized, and blinded study", Endosc Int Open, 3, pp.E471~E478 (2015)
- Thomas T, "Efficacy, safety, and predictive factors for a positive yield of EUS-guided Trucut biopsy : a large tertiary referral center experience", Am J Gastroenterol, 104, pp.584~591 (2009)
- Larghi A, "EUS-guided trucut needle biopsies in patients with solid pancreatic masses : a prospective study", Gastrointest Endosc, 59, pp.185~190 (2004)
- Iglesias-García J, "Evaluation of the adequacy and diagnostic accuracy of the histology samples obtained with a newly designed 19-gauge EUS histology needle", Rev Esp Enferm Dig, 106, pp.6~14 (2014)
- Shah JN, "Clinical impact of endoscopic ultrasonography on the management of malignancies", Clin Gastroenterol Hepatol, 2, pp.1069~1073 (2004)
- Levy MJ, "Preliminary experience with an EUS-guided trucut biopsy needle compared with EUS-guided FNA", Gastrointest Endosc, 57, pp.101~106 (2003)
- Varadarajulu S, "Endoscopic ultrasound-guided tissue acquisition", Dig Endosc, 26(Suppl 1), pp.62~69 (2014)
- 방지영, "Procore and Flexible 19 Gauge Needle Can Replace Trucut Biopsy Needle?", Clinical Endoscopy, 46(5), pp.503~505 (2013), 대한소화기내시경학회
- Varadarajulu S, "Assessment of the technical performance of the flexible 19-gauge EUS-FNA needle", Gastrointest Endosc, 76, pp.336~343 (2012)
- Varadarajulu S, "Quality assessment of current EUS-FNA assembly performance : adequate for use or opportunity for improvement", Gastrointest Endosc, 73(4 Suppl), pp.AB174~AB175 (2011)
- Itoi T, "Evaluation of 19-gauge endoscopic ultrasonography aspiration needles using various echoendoscopes", Endosc Int Open, 1, pp.24~30 (2013)
- Attili F, "Low diagnostic yield of transduodenal endoscopic ultrasound-guided fine needle biopsy using the 19-gauge Flex needle : a large multicenter prospective study", Endosc Ultrasound, 6, pp.402~408 (2017)
- Laquière A, "19 G nitinol needle versus 22 G needle for transduodenal endoscopic ultrasound-guided sampling of pancreatic solid masses : a randomized study", Endoscopy, 51, pp.436~443 (2019)
- Itoi T, "Puncture of solid pancreatic tumors guided by endoscopic ultrasonography : a pilot study series comparing Trucut and 19-gauge and 22-gauge aspiration needles", Endoscopy, 37, pp.362~366 (2005)
- Panic N, "Techniques for endoscopic ultrasound-guided fine-needle biopsy", Gastrointest Endosc Clin N Am, 24, pp.83~107 (2014)
- Kopelman Y, "Value of EUS-FNA cytological preparations compared with cell block sections in the diagnosis of pancreatic solid tumours", Cytopathology, 22, pp.174~178 (2011)
- Yasuda I, "Endoscopic ultrasound-guided fine-needle aspiration biopsy for lymphadenopathy of unknown origin", Endoscopy, 38, pp.919~924 (2006)
- Larghi A, "EUS-guided fine-needle tissue acquisition by using a 19-gauge needle in a selected patient population : a prospective study", Gastrointest Endosc, 74, pp.504~510 (2011)
- Varadarajulu S, "Role of EUS in drainage of peripancreatic fluid collections not amenable for endoscopic transmural drainage", Gastrointest Endosc, 66, pp.1107~1119 (2007)
- Kumbhari V, "Interventional EUS using a flexible 19-gauge needle : an international multicenter experience in 162 patients", Dig Dis Sci, 61, pp.3552~3559 (2016)