본문 바로가기
KERD
논문KCI 등재

3도 방실전도 차단 환자에서 절연손상으로 인한 자세변화에 따른 조율 장애 1예

Pacemaker malfunction related to insulation break according to position change in a patient with complete AV block

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류내과학

초록

저자들은 3도 방실전도 차단으로 인공심박동기를 삽입후 조율 유도의 절연손상으로 인해 조율 유도의 저항변화 없이 조율 역치와 감지도가 변하면서 자세 변화에 따라 간헐적인 조율 장애와 감지 장애를 보이는 환자에서 새로운 조율 유도 삽입 후 성공적으로 치료하였기에 이에 1예를 보고하는 바이다.

Abstract

A 53 year-old woman presented with intermittent dizziness and palpitation. She had received VVI type pacemaker due to complete AV block in 1990, and exchanged by VVIR type pacemaker thirteen years later. 1 year later, she suffered intermittent dizziness and palpitation in erect position, not in supine position. Intermittent pacing failure and sensing failure was observed in pacemaker test, especially in erect position, not in supine position. Pacing threshold was increased in erect position, but lead impedance was not changed. Insulation break was observed in bipolar lead by fluoroscope. Initially we tried a new lead implantation by cephalic access to prevent lead related complication, but failed. So, we implanted a new bipolar lead by subclavian access. Finally, she was treated by a new bipolar lead implantation.(Korean J Med 70:84-89, 2006)

참고문헌 (15)

  1. "심장학 교과서", pp.626~648 (2004)
  2. "ACC", AHA, AHA task force on Practice Guideline(ACC, pp.AHA, NASPE Committee to Update the 1988 Pacemaker Guidelines).
  3. "Braunwald's heart disease: a textbook of cardiovascular medicine.", pp.781~784 (2005)
  4. "Complication related to permanent pacemaker therapy", 22, pp.711~720 (1999)
  5. "Long-term complication rates in ventricular, single lead VDD, and dual chamber pacing", 26, pp.1961~1969 (2003)
  6. "Insulation lead failure: is it a matter of insulation coating, venous approach, or both?", 21, pp.418~421 (1998)
  7. "Anatomical mechanisms explaining damage to pacemaker leads and failure of central venous catheters adjacent to the sternoclavicular joint", pp.445~457 (1993)
  8. "Anatomical and morphological evaluation of pacemaker lead compression", 16, pp.434~444 (1993)
  9. "A new approach to percutaneous subclavian venipuncture to avoid lead fracture or central venous catheter occlusion", 16, pp.2133~2142 (1993)
  10. "A cephalic vein cutdown and venography technique to facilitate pacemaker and defibrillator lead implantation", 24, pp.469~473 (2001)
  11. "The cephalic vein cutdown versus subclavian puncture for pacemaker", ICD lead implantation, 1999, pp.22, 695~697
  12. "Venous cutdown for pacemaker implantation", 41, pp.438~439 (1986)
  13. "Safe and effective placement of two bipolar silicone leads in the cephalic vein using a hydrophilic guidewire and a split introducer", 23, pp.2065~2067 (2000)
  14. "Prospective study of axillary vein puncture with or without contrast venography for pacemaker and defibrillator lead implantation", 28, pp.280~283 (2005)
  15. "Cephalic vein guide wire technique for implantation of permanent pacemakers", 114, pp.753~756 (1987)

관련 논문AI추천

이 간행물의 다른 논문 (8건)