Predictive Factors for Inaccurate Diagnosis of Swollen Lymph Nodes in Endoscopic Ultrasound-Guided Fine Needle Aspiration
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background/Aims: This study aimed to identify the predictive factors for inaccurate endoscopic ultrasound-guided fine needleaspiration (EUS-FNA) diagnosis of swollen lymph nodes without rapid on-site cytopathological evaluation. Methods: Eighty-three consecutive patients who underwent EUS-FNA for abdominal or mediastinal lymph nodes from January2008 to June 2017 were included from a prospectively maintained EUS-FNA database and retrospectively reviewed. The sensitivity,specificity, and accuracy of EUS-FNA for the detection of neoplastic diseases were calculated. Candidate factors for inaccurate diagnosis(lymph node size and location, needle type, puncture route, number of passes, and causative disease) were evaluated by comparisonbetween accurately diagnosed cases and others. Results: The final diagnosis of the punctured lymph node was classified as neoplastic (65 cases: a metastatic lymph node, malignantlymphoma, or Crow-Fukase syndrome) or non-neoplastic (18 cases: a reactive node or amyloidosis). The sensitivity, specificity, andaccuracy were 83%, 94%, and 86%, respectively. On multivariate analyses, small size of the lymph node was the sole predictive factor forinaccurate EUS-FNA diagnosis with a significant difference (odds ratios, 19.8; 95% confidence intervals, 3.15–124; p=0.0015). Conclusions: The lymph node size of <16 mm was the only independent factor associated with inaccurate EUS-FNA diagnosis ofswollen lymph nodes.
Abstract
Background/Aims: This study aimed to identify the predictive factors for inaccurate endoscopic ultrasound-guided fine needleaspiration (EUS-FNA) diagnosis of swollen lymph nodes without rapid on-site cytopathological evaluation. Methods: Eighty-three consecutive patients who underwent EUS-FNA for abdominal or mediastinal lymph nodes from January2008 to June 2017 were included from a prospectively maintained EUS-FNA database and retrospectively reviewed. The sensitivity,specificity, and accuracy of EUS-FNA for the detection of neoplastic diseases were calculated. Candidate factors for inaccurate diagnosis(lymph node size and location, needle type, puncture route, number of passes, and causative disease) were evaluated by comparisonbetween accurately diagnosed cases and others. Results: The final diagnosis of the punctured lymph node was classified as neoplastic (65 cases: a metastatic lymph node, malignantlymphoma, or Crow-Fukase syndrome) or non-neoplastic (18 cases: a reactive node or amyloidosis). The sensitivity, specificity, andaccuracy were 83%, 94%, and 86%, respectively. On multivariate analyses, small size of the lymph node was the sole predictive factor forinaccurate EUS-FNA diagnosis with a significant difference (odds ratios, 19.8; 95% confidence intervals, 3.15–124; p=0.0015). Conclusions: The lymph node size of <16 mm was the only independent factor associated with inaccurate EUS-FNA diagnosis ofswollen lymph nodes.
참고문헌 (47)
- Wiersema MJ, "Endoscopic ultrasonography as an adjunct to fine needle aspiration cytology of the upper and lower gastrointestinal tract", Gastrointest Endosc, 38, pp.35~39 (1992)
- Ardengh JC, "Endoscopic ultrasound-guided biopsies for mediastinal lesions and lymph node diagnosis and staging", Clinics(Sao Paulo), 66, pp.1579~1583 (2011)
- Akahoshi K, "Clinical usefulness of endoscopic ultrasound-guided fine needle aspiration for gastric subepithelial lesions smaller than 2 cm", J Gastrointestin Liver Dis, 23, pp.405~412 (2014)
- Eckardt AJ, "Current endoscopic ultrasound-guided approach to incidental subepithelial lesions : optimal or optional", Ann Gastroenterol, 28, pp.160~172 (2015)
- Mekky MA, "Diagnostic utility of EUS-guided FNA in patients with gastric submucosal tumors", Gastrointest Endosc, 71, pp.913~919 (2010)
- Kaushik N, "EUS-guided paracentesis for the diagnosis of malignant ascites", Gastrointest Endosc, 64, pp.908~913 (2006)
- DeWitt J, "Survival in patients with pancreatic cancer after the diagnosis of malignant ascites or liver metastases by EUS-FNA", Gastrointest Endosc, 71, pp.260~265 (2010)
- DeWitt J, "Endoscopic ultrasound-guided fine-needle aspiration of ascites", Clin Gastroenterol Hepatol, 5, pp.609~615 (2007)
- Weilert F, "EUS-FNA is superior to ERCP-based tissue sampling in suspected malignant biliary obstruction : results of a prospective, single-blind, comparative study", Gastrointest Endosc, 80, pp.97~104 (2014)
- Kim HJ, "Diagnostic role of endoscopic ultrasonography-guided fine needle aspiration of gallbladder lesions", Hepatogastroenterology, 59, pp.1691~1695 (2012)
- Hijioka S, "Diagnostic yield of endoscopic retrograde cholangiography and of EUS-guided fine needle aspiration sampling in gallbladder carcinomas", J Hepatobiliary Pancreat Sci, 19, pp.650~655 (2012)
- Ogura T, "Can endoscopic ultrasound-guided fine needle aspiration offer clinical benefit for thick-walled gallbladders", Dig Dis Sci, 59, pp.1917~1924 (2014)
- Yasuda I, "Endoscopic ultrasound-guided fine-needle aspiration biopsy for lymphadenopathy of unknown origin", Endoscopy, 38, pp.919~924 (2006)
- Nakahara O, "Usefulness of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for undiagnosed intra-abdominal lymphadenopathy", J Gastroenterol, 44, pp.562~567 (2009)
- Naini BV, "A correlation study on diagnostic endoscopic ultrasound-guided fine-needle aspiration of lymph nodes with histological and clinical diagnoses, the UCLA Medical Center experience", Diagn Cytopathol, 36, pp.460~466 (2008)
- Kurita A, "Impact of EUS-FNA for preoperative para-aortic lymph node staging in patients with pancreatobiliary cancer", Gastrointest Endosc, 84, pp.467~475 (2016)
- Korenblit J, "The role of endoscopic ultrasound-guided fine needle aspiration (eusfna)for the diagnosis of intra-abdominal lymphadenopathy of unknown origin", J Interv Gastroenterol, 2, pp.172~176 (2012)
- Lee YN, "A triple approach for diagnostic assessment of endoscopic ultrasound-guided fine needle aspiration in pancreatic solid masses and lymph nodes", Dig Dis Sci, 59, pp.2286~2293 (2014)
- Iwashita T, "Endoscopic ultrasound-guided fine-needle aspiration in patients with lymphadenopathy suspected of recurrent malignancy after curative treatment", J Gastroenterol, 44, pp.190~196 (2009)
- Chen J, "Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesion: a systematic review", J Cancer Res Clin Oncol, 138, pp.1433~1441 (2012)
- Puli SR, "How good is endoscopic ultrasound-guided fine-needle aspiration in diagnosing the correct etiology for a solid pancreatic mass? : a meta-analysis and systematic review", Pancreas, 42, pp.20~26 (2013)
- Banafea O, "Endoscopic ultrasonography with fine-needle aspiration for histological diagnosis of solid pancreatic masses : a meta-analysis of diagnostic accuracy studies", BMC Gastroenterol, 16, pp.108~ (2016)
- Savides TJ, "Tricks for improving EUS-FNA accuracy and maximizing cellular yield", Gastrointest Endosc, 69(2 Suppl), pp.S130~S133 (2009)
- Matynia AP, "Impact of rapid on-site evaluation on the adequacy of endoscopic-ultrasound guided fine-needle aspiration of solid pancreatic lesions : a systematic review and meta-analysis", J Gastroenterol Hepatol, 29, pp.697~705 (2014)
- Hébert-Magee S, "The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma : a meta-analysis", Cytopathology, 24, pp.159~171 (2013)
- Cleveland P, "An evaluation of risk factors for inadequate cytology in EUS-guided FNA of pancreatic tumors and lymph nodes", Gastrointest Endosc, 71, pp.1194~1199 (2010)
- Kappelle WFW, "Rapid on-site evaluation during endoscopic ultrasound-guided fine-needle aspiration of lymph nodes does not increase diagnostic yield : a randomized, multicenter trial", Am J Gastroenterol, 113, pp.677~685 (2018)
- Noda Y, "Diagnostic efficacy of the cell block method in comparison with smear cytology of tissue samples obtained by endoscopic ultrasound-guided fine-needle aspiration", J Gastroenterol, 45, pp.868~875 (2010)
- LeBlanc JK, "Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis", Gastrointest Endosc, 59, pp.475~481 (2004)
- Wallace MB, "Randomized controlled trial of EUS-guided fine needle aspiration techniques for the detection of malignant lymphadenopathy", Gastrointest Endosc, 54, pp.441~447 (2001)
- Pellisé Urquiza M, "Endoscopic ultrasound-guided fine needle aspiration : predictive factors of accurate diagnosis and cost-minimization analysis of on-site pathologist", Gastroenterol Hepatol, 30, pp.319~324 (2007)
- Chin YK, "Accuracy of endoscopic ultrasound-guided tissue acquisition in the evaluation of lymph nodes enlargement in the absence of on-site pathologist", World J Gastroenterol, 23, pp.5755~5763 (2017)
- Klapman JB, "Clinical impact of onsite cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration", Am J Gastroenterol, 98, pp.1289~1294 (2003)
- Jhala NC, "Endoscopic ultrasound-guided fine-needle aspiration biopsy : a powerful tool to obtain samples from small lesions", Cancer, 102, pp.239~246 (2004)
- Alsohaibani F, "Does onsite cytotechnology evaluation improve the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsy?", Can J Gastroenterol, 23, pp.26~30 (2009)
- Jeong SH, "High-resolution endoscopic ultrasound imaging and the number of needle passages are significant factors predicting high yield of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid masses without an on-site cytopathologist", Medicine (Baltimore), 96, pp.e5782~ (2017)
- Ribeiro A, "EUS-guided fine-needle aspiration combined with flow cytometry and immunocytochemistry in the diagnosis of lymphoma", Gastrointest Endosc, 53, pp.485~491 (2001)
- Faries MB, "Active macromolecule uptake by lymph node antigen-presenting cells : a novel mechanism in determining sentinel lymph node status", Ann Surg Oncol, 7, pp.98~105 (2000)
- Carter BA, "Benign transport of breast epithelium into axillary lymph nodes after biopsy", Am J Clin Pathol, 113, pp.259~265 (2000)
- Hartveit F, "Micrometastases to the axilla in breast cancer : their size and season of presentation", Invasion Metastasis, 16, pp.144~149 (1996)
- Wiersema MJ, "Mediastinal lymph node detection with endosonography", Gastrointest Endosc, 39, pp.788~793 (1993)
- Catalano MF, "Endosonographic features predictive of lymph node metastasis", Gastrointest Endosc, 40, pp.442~446 (1994)
- Bhutani MS, "A comparison of the accuracy of echo features during endoscopic ultrasound(EUS)and EUS-guided fine-needle aspiration for diagnosis of malignant lymph node invasion", Gastrointest Endosc, 45, pp.474~479 (1997)
- Choudhary NS, "Yield of endoscopic ultrasound-guided fine needle aspiration for subcentimetric lymph nodes : a comparison to larger nodes", Endosc Ultrasound, 6, pp.168~173 (2017)
- Sazuka T, "Assessment for diagnosis of lymph node metastasis in esophageal cancer using endoscopic ultrasound elastography", Esophagus, 13, pp.254~263 (2016)
- Rubaltelli L, "Evaluation of lymph node perfusion using continuous mode harmonic ultrasonography with a second-generation contrast agent", J Ultrasound Med, 23, pp.829~836 (2004)
- Hocke M, "Role of contrast-enhanced endoscopic ultrasound in lymph nodes", Endosc Ultrasound, 6, pp.4~11 (2017)