본문 바로가기
KERD
논문KCI 등재

Comparison of 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma using endoscopic ultrasound fine-needle aspiration

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using a 19-gauge needle is an efficient sampling method for the diagnosis of lymphadenopathy. This study compared 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma (ML). Methods: Patient characteristics, number of needle passes, puncture route, sensitivity, specificity, and accuracy of cytology/histology for lymphadenopathy were analyzed in patients diagnosed with lymphadenopathy by EUS-FNA using conventional or Franseen needles. Results: Between 2012 and 2022, 146 patients met the inclusion criteria (conventional [n=70] and Franseen [n=76]). The median number of needle passes was significantly lower in the conventional group than in the Franseen group (3 [1–6] vs. 4 [1–6], p=0.023). There were no significant differences in cytological/ histological diagnoses between the two groups. For ML, the immunohistochemical evaluation rate, sensitivity of flow cytometry, and cytogenetic assessment were not significantly different in either group. Bleeding as adverse events (AEs) were observed in three patients in the Franseen group. Conclusions: Both the 19-gauge conventional and Franseen needles showed high accuracy in lymphadenopathy and ML classification. Considering sufficient tissue collection and the avoidance of AEs, the use of 19-gauge conventional needles seems to be a good option for the diagnosis of lymphadenopathy.

Abstract

Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using a 19-gauge needle is an efficient sampling method for the diagnosis of lymphadenopathy. This study compared 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma (ML). Methods: Patient characteristics, number of needle passes, puncture route, sensitivity, specificity, and accuracy of cytology/histology for lymphadenopathy were analyzed in patients diagnosed with lymphadenopathy by EUS-FNA using conventional or Franseen needles. Results: Between 2012 and 2022, 146 patients met the inclusion criteria (conventional [n=70] and Franseen [n=76]). The median number of needle passes was significantly lower in the conventional group than in the Franseen group (3 [1–6] vs. 4 [1–6], p=0.023). There were no significant differences in cytological/ histological diagnoses between the two groups. For ML, the immunohistochemical evaluation rate, sensitivity of flow cytometry, and cytogenetic assessment were not significantly different in either group. Bleeding as adverse events (AEs) were observed in three patients in the Franseen group. Conclusions: Both the 19-gauge conventional and Franseen needles showed high accuracy in lymphadenopathy and ML classification. Considering sufficient tissue collection and the avoidance of AEs, the use of 19-gauge conventional needles seems to be a good option for the diagnosis of lymphadenopathy.

참고문헌 (18)

  1. Wani S, "EUS-guided tissue acquisition : an evidence-based approach(with videos)", Gastrointest Endosc, 80, pp.939~959 (2014)
  2. Yasuda I, "Endoscopic ultrasound-guided fine needle aspiration biopsy for diagnosis of lymphoproliferative disorders : feasibility of immunohistological, flow cytometric, and cytogenetic assessments", Am J Gastroenterol, 107, pp.397~404 (2012)
  3. Itoi T, "Histological diagnosis by EUS-guided fine-needle aspiration biopsy in pancreatic solid masses without on-site cytopathologist : a single-center experience", Dig Endosc, 23(Suppl 1), pp.34~38 (2011)
  4. Bang JY, "A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition", Endoscopy, 48, pp.339~349 (2016)
  5. Yasuda I, "Endoscopic ultrasound-guided fine-needle aspiration biopsy for lymphadenopathy of unknown origin", Endoscopy, 38, pp.919~924 (2006)
  6. Mukai S, "A retrospective histological comparison of EUS-guided fine-needle biopsy using a novel franseen needle and a conventional end-cut type needle", Endosc Ultrasound, 8, pp.50~57 (2019)
  7. Sugimoto M, "Efficacy of EUS-guided FNB using a Franseen needle for tissue acquisition and microsatellite instability evaluation in unresectable pancreatic lesions", BMC Cancer, 20, pp.1094~ (2020)
  8. de Moura DT, "EUS-guided fine-needle biopsy sampling versus FNA in the diagnosis of subepithelial lesions : a large multicenter study", Gastrointest Endosc, 92, pp.108~119 (2020)
  9. Itonaga M, "Comparison of 22-gauge standard and Franseen needles in EUS-guided tissue acquisition for diagnosing solid pancreatic lesions : a multicenter randomized controlled trial", Gastrointest Endosc, 96, pp.57~66 (2022)
  10. Swerdlow SH, "The 2016 revision of the World Health Organization classification of lymphoid neoplasms", Blood, 127, pp.2375~2390 (2016)
  11. Facciorusso A, "Endoscopic ultrasound fine-needle biopsy versus fine-needle aspiration for tissue sampling of abdominal lymph nodes : a propensity score matched multicenter comparative study", Cancers(Basel), 13, pp.4298~ (2021)
  12. Hedenström P, "High sensitivity of endoscopic ultrasound-guided fine-needle aspiration and endoscopic ultrasound-guided fine-needle biopsy in lymphadenopathy caused by metastatic disease : a prospective comparative study", Clin Endosc, 54, pp.722~729 (2021)
  13. de Moura DT, "Endoscopic ultrasound fine-needle aspiration versus fine-needle biopsy for lymph node diagnosis : a large multicenter comparative analysis", Clin Endosc, 53, pp.600~610 (2020)
  14. Farinha P, "Molecular pathogenesis of mucosa-associated lymphoid tissue lymphoma", J Clin Oncol, 23, pp.6370~6378 (2005)
  15. Nadel B, "Novel insights into the mechanism of t(14;18)(q32;q21)translocation in follicular lymphoma", Leuk Lymphoma, 42, pp.1181~1194 (2001)
  16. Le Gouill S, "The clinical presentation and prognosis of diffuse large B-cell lymphoma with t(14;18)and 8q24", c-MYC rearrangement, 2007, pp.92, 1335~1342
  17. Camacho FI, "Aberrant Bcl6 protein expression in mantle cell lymphoma", Am J Surg Pathol, 28, pp.1051~1056 (2004)
  18. Yoshida K, "Efficacy of contrast-enhanced EUS for lymphadenopathy : a prospective multicenter pilot study(with videos)", Gastrointest Endosc, 90, pp.242~250 (2019)

관련 논문AI추천

A retrospective study on the comparative use of fine-needle biopsy and aspiration for the diagnosis and classification of malignant lymphoma in JapanAkihiro Nakamura, Fumitaka Niiya, Jun Noda, Masataka Yamawaki, Masatsugu Nagahama, Naoki Tamai, Takafumi Ogawa, Tetsushi Azami, Yasuo Ueda, Yuichi Takano대한소화기내시경학회 · Clinical Endoscopy2025 · 제58권 제5호High Sensitivity of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Endoscopic Ultrasound-Guided Fine-Needle Biopsy in Lymphadenopathy Caused by Metastatic Disease: A Prospective Comparative StudyCatarina Lewerin, Per Hedenström, Riadh Sadik, Roozbeh Shams, Vasilis Chatzikyriakos대한소화기내시경학회 · Clinical Endoscopy2021 · 제54권 제5호Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using a 20-Gauge Menghini Needle with a Lateral Forward Bevel and a 22-Gauge Franseen Needle: A Single-Center Large Cohort StudyAkiyoshi Kasuga, Masato Matsuyama, Masato Ozaka, Naoki Sasahira, Ryo Kanata, Takaaki Furukawa, Takafumi Mie, Takashi Sasaki, Tsuyoshi Takeda대한소화기내시경학회 · Clinical Endoscopy2021 · 제54권 제5호Predictive Factors for Inaccurate Diagnosis of Swollen Lymph Nodes in Endoscopic Ultrasound-Guided Fine Needle AspirationFumisato Kozakai, Hiroaki Kusunose, Hiroyuki Okada, Kaori Masu, Kei Ito, Keisuke Yonamine, Shinsuke Koshita, Takahisa Ogawa, Toji Murabayashi, Toshitaka Sakai, Yoshihide Kanno, Yujiro Kawakami, Yuki Fujii, Yutaka Noda대한소화기내시경학회 · Clinical Endoscopy2019 · 제52권 제2호Endoscopic Ultrasound Fine-Needle Aspiration versus Fine-Needle Biopsy for Lymph Node Diagnosis: A Large Multicenter Comparative AnalysisChristopher C. Thompson, Diogo Turiani Hourneaux de Moura, Galileu Ferreira Ayala Farias, Igor Braga Ribeiro, Linda S. Lee, Marvin Ryou, Pichamol Jirapinyo, Thomas R. McCarty대한소화기내시경학회 · Clinical Endoscopy2020 · 제53권 제5호Choosing needles wisely: 19-G conventional vs. Franseen needles in endoscopic ultrasound-guided fine-needle aspiration for malignant lymphoma diagnosis and classificationKajornvit Raghareutai, Nonthalee Pausawasdi, Worapoth Yingyongthawat대한소화기내시경학회 · Clinical Endoscopy2024 · 제57권 제4호

이 간행물의 다른 논문 (18건)