64절편 다검출기 CT 관상동맥 조영술을 이용한 관상동맥 질환 진단의 정확도
Diagnostic accuracy of 64-slice multi-detector CT coronary angiography in the evaluation of coronary artery disease
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Conventional coronary angiography (CCA) has been the gold standard for the detection of significant coronary artery disease (CAD). However, CCA is invasive and 2/3 of all CCA have been performed for the diagnosis of significant stenosis without intervention. Recently, the use of multi-detector CT (MDCT) coronary angiography has been rapidly evolving as a promising non-invasive method for the assessment of patients with CAD. With the advent of 64-slice MDCT scanner, both temporal and spatial resolutions of coronary CT angiography have further improved for the non-invasive detection of coronary stenoses. The diagnostic performance for the assessment of CAD has significantly improved, and the nonassessable proportion of segments significantly decreased with the newer generations of MDCT scanners. Namgung et al. reported that high diagnostic accuracy for 64-slice MDCT in the detection of significant stenosis (≥50% lumen diameter narrowing) on per segment (96% sensitivity and 97% specificity), per vessel (96% sensitivity and 97% specificity), and per patient analyses (100% sensitivity and 94% specificity). The negative predictive value for classification of segments, vessels, and patients with or without CAD was very high (99-100%). These findings indicate that 64-slice MDCT coronary angiography can be reliable as a gatekeeper of CCA in selected groups of patients. (Korean J Med 75:39-41, 2008)
Abstract
Conventional coronary angiography (CCA) has been the gold standard for the detection of significant coronary artery disease (CAD). However, CCA is invasive and 2/3 of all CCA have been performed for the diagnosis of significant stenosis without intervention. Recently, the use of multi-detector CT (MDCT) coronary angiography has been rapidly evolving as a promising non-invasive method for the assessment of patients with CAD. With the advent of 64-slice MDCT scanner, both temporal and spatial resolutions of coronary CT angiography have further improved for the non-invasive detection of coronary stenoses. The diagnostic performance for the assessment of CAD has significantly improved, and the nonassessable proportion of segments significantly decreased with the newer generations of MDCT scanners. Namgung et al. reported that high diagnostic accuracy for 64-slice MDCT in the detection of significant stenosis (≥50% lumen diameter narrowing) on per segment (96% sensitivity and 97% specificity), per vessel (96% sensitivity and 97% specificity), and per patient analyses (100% sensitivity and 94% specificity). The negative predictive value for classification of segments, vessels, and patients with or without CAD was very high (99-100%). These findings indicate that 64-slice MDCT coronary angiography can be reliable as a gatekeeper of CCA in selected groups of patients. (Korean J Med 75:39-41, 2008)
참고문헌 (9)
- American Heart Association, "Heart disease and stroke statistics- 2004 update", pp.40~ (2003), American Heart Association
- Hamon M, "Coronary arteries: diagnostic performance of 16-versus 64-section spiral CT compared with invasive coronary angiography--metaanalysis", Radiology, 245, pp.720~731 (2007)
- Garcia MJ, "Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis", JAMA, 296, pp.403~411 (2006)
- Brodoefel H, "Noninvasive coronary angiography using 64-slice spiral computed tomography in an unselected patient collective: effect of heart rate, heart rate variability and coronary calcifications on image quality and diagnostic accuracy", Eur J Radiol, 66, pp.134~141 (2008)
- Weustink AC, "Reliable high-speed coronary computed tomography in symptomatic patients", J Am Coll cardiol, 50, pp.786~794 (2007)
- Hendel RC, "ACCF", ACR, SCMR, pp.ASNC, NASCI[DOI]
- Einstein AJ, "Estimating risk of cancer associated with radiation exposure from 64-slice CT coronary angiography", JAMA, 18(298), pp.317~323 (2007)
- Brenner DJ, "Computed tomography -- an increasing source of radiation exposure", N Engl J Med, 29(357), pp.2277~2284 (2007)
- Husmann L, "Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating", Eur heart J, 29, pp.191~197 (2008)