본문 바로가기
KERD
논문KCI 등재

Multimodality Imaging in Coronary Artery Disease: Focus on Computed Tomography

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류내과학

초록

Coronary artery disease (CAD) is the leading cause of mortality worldwide, and various cardiovascular imaging modalities havebeen introduced for the purpose of diagnosing and determining the severity of CAD. More recently, advances in computed tomography(CT) technology have contributed to the widespread clinical application of cardiac CT for accurate and noninvasive evaluationof CAD. In this review, we focus on imaging assessment of CAD based upon CT, which includes coronary artery calciumscreening, coronary CT angiography, myocardial CT perfusion, and fractional flow reserve CT. Further, we provide a discussion regardingthe potential implications, benefits and limitations, as well as the possible future directions according to each modality.

Abstract

Coronary artery disease (CAD) is the leading cause of mortality worldwide, and various cardiovascular imaging modalities havebeen introduced for the purpose of diagnosing and determining the severity of CAD. More recently, advances in computed tomography(CT) technology have contributed to the widespread clinical application of cardiac CT for accurate and noninvasive evaluationof CAD. In this review, we focus on imaging assessment of CAD based upon CT, which includes coronary artery calciumscreening, coronary CT angiography, myocardial CT perfusion, and fractional flow reserve CT. Further, we provide a discussion regardingthe potential implications, benefits and limitations, as well as the possible future directions according to each modality.

참고문헌 (54)

  1. Agatston AS, "Quantification of coronary artery calcium using ultrafast computed tomography", J Am Coll Cardiol, 15, pp.827~832 (1990)
  2. Yeboah J, "Comparison of novel risk markers for improvement in cardiovascular risk assessment in intermediate-risk individuals", JAMA, 308, pp.788~795 (2012)
  3. Greenland P, "Coronary artery calcium score combined with Framingham score for risk prediction in asymptomatic individuals", JAMA, 291, pp.210~215 (2004)
  4. Sarwar A, "Diagnostic and prognostic value of absence of coronary artery calcification", JACC Cardiovasc Imaging, 2, pp.675~688 (2009)
  5. Folsom AR, "Coronary artery calcification compared with carotid intima-media thickness in the prediction of cardiovascular disease incidence: the Multi-Ethnic Study of Atherosclerosis (MESA)", Arch Intern Med, 168, pp.1333~1339 (2008)
  6. Goff DC Jr, "2013 ACC", AHA guideline on the assessment of cardiovascular risk: a report of the American College of Cardiology, Circulation, pp.2014, 129(25 Suppl 2)[DOI]
  7. Rubinshtein R, "Prevalence and extent of obstructive coronary artery disease in patients with zero or low calcium score undergoing 64-slice cardiac multidetector computed tomography for evaluation of a chest pain syndrome", Am J Cardiol, 99, pp.472~475 (2007)
  8. Einstein AJ, "Cardiac imaging: does radiation matter?", Eur Heart J, 33, pp.573~578 (2012)
  9. Pencina MJ, "Application of new cholesterol guidelines to a population-based sample", N Engl J Med, 370, pp.1422~1431 (2014)
  10. Nasir K, "Implications of coronary artery calcium testing among statin candidates according to American College of Cardiology", American Heart Association Cholesterol Management Guidelines: MESA (MultiEthnic Study of Atherosclerosis), 2015, pp.66, 1657~1668
  11. Miedema MD, "Use of coronary artery calcium testing to guide aspirin utilization for primary prevention:estimates from the multi-ethnic study of atherosclerosis", Circ Cardiovasc Qual Outcomes, 7, pp.453~460 (2014)
  12. Bittencourt MS, "Polypill therapy, subclinical atherosclerosis, and cardiovascular events-implications for the use of preventive pharmacotherapy: MESA (Multi-Ethnic Study of Atherosclerosis)", J Am Coll Cardiol, 63, pp.434~443 (2014)
  13. Villines TC, "Prevalence and severity of coronary artery disease and adverse events among symptomatic patients with coronary artery calcification scores of zero undergoing coronary computed tomography angiography: results from the CONFIRM (Coronary CT Angiography Evaluation for Clinical Outcomes: An International Multicenter)registry", J Am Coll Cardiol, 58, pp.2533~2540 (2011)
  14. Hecht HS, "Combined detection of coronary artery disease and lung cancer", Eur Heart J, 35, pp.2792~2796 (2014)
  15. Budoff MJ, "Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial", J Am Coll Cardiol, 52, pp.1724~1732 (2008)
  16. Miller JM, "Diagnostic performance of coronary angiography by 64-row CT", N Engl J Med, 359, pp.2324~2336 (2008)
  17. Meijboom WB, "Diagnostic accuracy of 64-slice computed tomography coronary angiography:a prospective, multicenter, multivendor study", J Am Coll Cardiol, 52, pp.2135~2144 (2008)
  18. Min JK, "Age- and sex-related differences in all-cause mortality risk based on coronary computed tomography angiography findings results from the International Multicenter CONFIRM (Coronary CT Angiography Evaluation for Clinical Outcomes: An International Multicenter Registry) of 23,854 patients without known coronary artery disease", J Am Coll Cardiol, 58, pp.849~860 (2011)
  19. Douglas PS, "Outcomes of anatomical versus functional testing for coronary artery disease", N Engl J Med, 372, pp.1291~1300 (2015)
  20. Taylor AJ, "ACCF", SCCT, AHA, pp.ASE, ASNC[DOI]
  21. Choi EK, "Coronary computed tomography angiography as a screening tool for the detection of occult coronary artery disease in asymptomatic individuals", J Am Coll Cardiol, 52, pp.357~365 (2008)
  22. Min JK, "Incremental prognostic value of coronary computed tomographic angiography over coronary artery calcium score for risk prediction of major adverse cardiac events in asymptomatic diabetic individuals", Atherosclerosis, 232, pp.298~304 (2014)
  23. Cho I, "Coronary computed tomographic angiography and risk of all-cause mortality and nonfatal myocardial infarction in subjects without chest pain syndrome from the CONFIRM Registry (coronary CT angiography evaluation for clinical outcomes: an international multicenter registry)", Circulation, 126, pp.304~313 (2012)
  24. Muhlestein JB, "Effect of screening for coronary artery disease using CT angiography on mortality and cardiac events in high-risk patients with diabetes: the FACTOR-64randomized clinical trial", JAMA, 312, pp.2234~2243 (2014)
  25. Fischer C, "Coronary CT angiography versus intravascular ultrasound for estimation of coronary stenosis and atherosclerotic plaque burden: a meta-analysis", J Cardiovasc Comput Tomogr, 7, pp.256~266 (2013)
  26. Park HB, "Atherosclerotic plaque characteristics by CT angiography identify coronary lesions that cause ischemia: a direct comparison to fractional flow reserve", JACC Cardiovasc Imaging, 8, pp.1~10 (2015)
  27. Virmani R, "Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions", Arterioscler Thromb Vasc Biol, 20, pp.1262~1275 (2000)
  28. Di Carli MF, "Relationship between CT coronary angiography and stress perfusion imaging in patients with suspected ischemic heart disease assessed by integrated PET-CT imaging", J Nucl Cardiol, 14, pp.799~809 (2007)
  29. Ko BS, "Computed tomography stress myocardial perfusion imaging in patients considered for revascularization: a comparison with fractional flow reserve", Eur Heart J, 33, pp.67~77 (2012)
  30. Rochitte CE, "Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography:the CORE320 study", Eur Heart J, 35, pp.1120~1130 (2014)
  31. Bamberg F, "Detection of hemodynamically significant coronary artery stenosis: incremental diagnostic value of dynamic CT-based myocardial perfusion imaging", Radiology, 260, pp.689~698 (2011)
  32. Bamberg F, "Dynamic myocardial CT perfusion imaging for evaluation of myocardial ischemia as determined by MR imaging", JACC Cardiovasc Imaging, 7, pp.267~277 (2014)
  33. Ho KT, "Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT", JACC Cardiovasc Imaging, 3, pp.811~820 (2010)
  34. Koo BK, "Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter DISCOVER-FLOW (Diagnosis of Ischemia-Causing Stenoses Obtained Via Noninvasive Fractional Flow Reserve) study", J Am Coll Cardiol, 58, pp.1989~1997 (2011)
  35. Min JK, "Diagnostic accuracy of fractional flow reserve from anatomic CT angiography", JAMA, 308, pp.1237~1245 (2012)
  36. Nørgaard BL, "Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps)", J Am Coll Cardiol, 63, pp.1145~1155 (2014)
  37. Hlatky MA, "Projected costs and consequences of computed tomography-determined fractional flow reserve", Clin Cardiol, 36, pp.743~748 (2013)
  38. Douglas PS, "Clinical outcomes of fractional flow reserve by computed tomographic angiography-guided diagnostic strategies vs. usual care in patients with suspected coronary artery disease: the prospective longitudinal trial of FFRCT: outcome and resource impacts study", Eur Heart J, 36, pp.3359~3367 (2015)
  39. Kim KH, "A novel noninvasive technology for treatment planning using virtual coronary stenting and com-puted tomography-derived computed fractional flow reserve", JACC Cardiovasc Interv, 7, pp.72~78 (2014)
  40. Danad I, "New applications of cardiac computed tomography: dual-energy, spectral, and molecular CT imaging", JACC Cardiovasc Imaging, 8, pp.710~723 (2015)
  41. Ruzsics B, "Comparison of dual-energy computed tomography of the heart with single photon emission computed tomography for assessment of coronary artery stenosis and of the myocardial blood supply", Am J Cardiol, 104, pp.318~326 (2009)
  42. Kim SM, "Dual-energy CT perfusion during pharmacologic stress for the assessment of myocardial perfusion defects using a second-generation dual-source CT: a comparison with cardiac magnetic resonance imaging", J Comput Assist Tomogr, 38, pp.44~52 (2014)
  43. Truong QA, "Rationale and design of the dual-energy computed tomography for ischemia determination compared to “gold standard” non-invasive and invasive techniques (DECIDEGold):a multicenter international efficacy diagnostic study of rest-stress dual-energy computed tomography angiography with perfusion", J Nucl Cardiol, 22, pp.1031~1040 (2015)
  44. Virmani R, "Pathology of the vulnerable plaque", J Am Coll Cardiol, 47(8 Suppl), pp.C13~C18 (2006)
  45. Becker CR, "Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT", Eur Radiol, 13, pp.2094~2098 (2003)
  46. Obaid DR, "Dual-energy computed tomography imaging to determine atherosclerotic plaque composition: a prospective study with tissue validation", J Cardiovasc Comput Tomogr, 8, pp.230~237 (2014)
  47. Raju R, "Reduced iodine load with CT coronary angiography using dual-energy imaging: a prospective randomized trial compared with standard coronary CT angiography", J Cardiovasc Comput Tomogr, 8, pp.282~288 (2014)
  48. Pontone G, "Coronary artery disease: diagnostic accuracy of CT coronary angiography--a comparison of high and standard spatial resolution scanning", Radiology, 271, pp.688~694 (2014)
  49. Primak AN, "Relationship between noise, dose, and pitch in cardiac multi-detector row CT", Radiographics, 26, pp.1785~1794 (2006)
  50. Stolzmann P, "Predictors of image quality in high-pitch coronary CT angiography", AJR Am J Roentgenol, 197, pp.851~858 (2011)
  51. Wong DT, "Superior CT coronary angiography image quality at lower radiation exposure with second generation 320-detector row CT in patients with elevated heart rate: a comparison with first generation 320-detector row CT", Cardiovasc Diagn Ther, 4, pp.299~306 (2014)
  52. Leipsic J, "Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medications", J Cardiovasc Comput Tomogr, 6, pp.164~171 (2012)
  53. Andreini D, "Low-dose CT coronary angiography with a novel IntraCycle motion-correction algorithm in patients with high heart rate or heart rate variability", Eur Heart J Cardiovasc Imaging, 16, pp.1093~1100 (2015)
  54. Min JK, "Rationale and design of the ViCTORY (Validation of an Intracycle CT Motion CORrection Algorithm for Diagnostic AccuracY) trial", J Cardiovasc Comput Tomogr, 7, pp.200~206 (2013)

관련 논문AI추천

이 간행물의 다른 논문 (17건)