high tumors. Therefore, sufficient sampling of histological specimens is necessary in cases of unresectable pancreatic cancer (UR-PC). This multicenter study investigated the efficacy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) using a Franseen needlefor MSI evaluation in patients with UR-PC. Methods: A total of 89 patients with UR-PC who underwent endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) orEUS-FNB using 22-G needles at three hospitals in Japan (2018–2021) were enrolled. Fifty-six of these patients (FNB 23 and FNA 33)were followed up or evaluated for MSI. Patient characteristics, UR-PC data, and procedural outcomes were compared between patientswho underwent EUS-FNB and those who underwent EUS-FNA. Results: No significant difference in terms of sufficient tissue acquisition for histology was observed between patients who underwentEUS-FNB and those who underwent EUS-FNA. MSI evaluation was possible significantly more with tissue samples obtained usingEUS-FNB than with tissue samples obtained using EUS-FNA (82.6% [19/23] vs. 45.5% [15/33], respectively; p<0.01). In the multivariateanalysis, EUS-FNB was the only significant factor influencing the possibility of MSI evaluation. Conclusions: EUS-FNB using a Franseen needle is desirable for ensuring sufficient tissue acquisition for MSI evaluation.

Abstract

high tumors. Therefore, sufficient sampling of histological specimens is necessary in cases of unresectable pancreatic cancer (UR-PC). This multicenter study investigated the efficacy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) using a Franseen needlefor MSI evaluation in patients with UR-PC. Methods: A total of 89 patients with UR-PC who underwent endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) orEUS-FNB using 22-G needles at three hospitals in Japan (2018–2021) were enrolled. Fifty-six of these patients (FNB 23 and FNA 33)were followed up or evaluated for MSI. Patient characteristics, UR-PC data, and procedural outcomes were compared between patientswho underwent EUS-FNB and those who underwent EUS-FNA. Results: No significant difference in terms of sufficient tissue acquisition for histology was observed between patients who underwentEUS-FNB and those who underwent EUS-FNA. MSI evaluation was possible significantly more with tissue samples obtained usingEUS-FNB than with tissue samples obtained using EUS-FNA (82.6% [19/23] vs. 45.5% [15/33], respectively; p<0.01). In the multivariateanalysis, EUS-FNB was the only significant factor influencing the possibility of MSI evaluation. Conclusions: EUS-FNB using a Franseen needle is desirable for ensuring sufficient tissue acquisition for MSI evaluation.

참고문헌 (28)

  1. Siegel RL, "Cancer statistics, 2020", CA Cancer J Clin, 70, pp.7~30 (2020)
  2. Stathis A, "Advanced pancreatic carcinoma : current treatment and future challenges", Nat Rev Clin Oncol, 7, pp.163~172 (2010)
  3. Warsame R, "Treatment options for advanced pancreatic cancer : a review", Expert Rev Anticancer Ther, 12, pp.1327~1336 (2012)
  4. Fogel EL, "A multidisciplinary approach to pancreas cancer in 2016 : a review", Am J Gastroenterol, 112, pp.537~554 (2017)
  5. Sohal DPS, "Metastatic pancreatic cancer : ASCO guideline update", J Clin Oncol, 38, pp.3217~3230 (2020)
  6. Okusaka T, "Recent advances in chemotherapy for pancreatic cancer : evidence from Japan and recommendations in guidelines", J Gastroenterol, 55, pp.369~382 (2020)
  7. Williams DB, "Endoscopic ultrasound guided fine needle aspiration biopsy : a large single centre experience", Gut, 44, pp.720~726 (1999)
  8. Yoshinaga S, "Role of endoscopic ultrasound-guided fine needle aspiration(EUS-FNA)for diagnosis of solid pancreatic masses", Dig Endosc, 23(Suppl 1), pp.29~33 (2011)
  9. Uehara H, "Diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration for suspected pancreatic malignancy in relation to the size of lesions", J Gastroenterol Hepatol, 26, pp.1256~1261 (2011)
  10. Mukai S, "A retrospective histological comparison of EUS-guided fine-needle biopsy using a novel Franseen needle and a conventional end-cut type needle", Endosc Ultrasound, 8, pp.50~57 (2019)
  11. Sugiura R, "Prospective, multicenter, observational study of tissue acquisition through EUS-guided fine-needle biopsy using a 25G Franseen needle", Endosc Ultrasound, 8, pp.321~328 (2019)
  12. Sugimoto M, "Efficacy of EUS-guided FNB using a Franseen needle for tissue acquisition and microsatellite instability evaluation in unresectable pancreatic lesions", BMC Cancer, 20, pp.1094~ (2020)
  13. Hikichi T, "Endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic masses with rapid on-site cytological evaluation by endosonographers without attendance of cytopathologists", J Gastroenterol, 44, pp.322~328 (2009)
  14. Suzuki R, "Prospective evaluation of the optimal number of 25-gauge needle passes for endoscopic ultrasound-guided fine-needle aspiration biopsy of solid pancreatic lesions in the absence of an onsite cytopathologist", Dig Endosc, 24, pp.452~456 (2012)
  15. Varadhachary GR, "Borderline resectable pancreatic cancer : definitions, management, and role of preoperative therapy", Ann Surg Oncol, 13, pp.1035~1046 (2006)
  16. Japan Pancreas Society, "General rules for the study of pancreatic cancer" (2016), Kanehara & Co., Ltd
  17. Yamamoto H, "Genetic and clinical features of human pancreatic ductal adenocarcinomas with widespread microsatellite instability", Cancer Res, 61, pp.3139~3144 (2001)
  18. Murphy KM, "Comparison of the microsatellite instability analysis system and the Bethesda panel for the determination of microsatellite instability in colorectal cancers", J Mol Diagn, 8, pp.305~311 (2006)
  19. Kurata K, "Microsatellite instability in Japanese female patients with triple-negative breast cancer", Breast Cancer, 27, pp.490~498 (2020)
  20. Bando H, "Utility of the quasi-monomorphic variation range in unresectable metastatic colorectal cancer patients", Cancer Sci, 109, pp.3411~3415 (2018)
  21. Patil DT, "A five-marker panel in a multiplex PCR accurately detects microsatellite instability-high colorectal tumors without control DNA", Diagn Mol Pathol, 21, pp.127~133 (2012)
  22. Kanda Y, "Investigation of the freely available easy-to-use software ‘EZR’ for medical statistics", Bone Marrow Transplant, 48, pp.452~458 (2013)
  23. Polkowski M, "Technical aspects of endoscopic ultrasound(EUS)-guided sampling in gastroenterology : European Society of Gastrointestinal Endoscopy(ESGE)Technical Guideline-March 2017", Endoscopy, 49, pp.989~1006 (2017)
  24. Le DT, "Mismatch repair deficiency predicts response of solid tumors to PD-1 blockade", Science, 357, pp.409~413 (2017)
  25. Luchini C, "Microsatellite instability", mismatch repair deficiency in pancreatic cancers : the same or different?, 2021, pp.70, 1809~1811
  26. Singhi AD, "Real-time targeted genome profile analysis of pancreatic ductal adenocarcinomas identifies genetic alterations that might be targeted with existing drugs or used as biomarkers", Gastroenterology, 156, pp.2242~2253 (2019)
  27. Kamatham S, "Circulating tumor DNA-based detection of microsatellite instability and response to immunotherapy in pancreatic cancer", Front Pharmacol, 11, pp.23~ (2020)
  28. Obayashi M, "Pancreatic undifferentiated carcinoma with osteoclast-like giant cells curatively resected after pembrolizumab therapy for lung metastases : a case report", BMC Gastroenterol, 20, pp.220~ (2020)

관련 논문AI추천

Clinical utility of endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling of pancreatic cancerDaiki Fumihara, Kazuo Hara, Nobumasa Mizuno, Nozomi Okuno, Shin Haba, Takafumi Yanaidani, Takamichi Kuwahara, Yasuhiro Kuraishi대한소화기내시경학회 · Clinical Endoscopy2023 · 제56권 제2호Endoscopic Ultrasound-Guided Tissue Acquisition by 22-Gauge Franseen and Standard Needles for Solid Pancreatic LesionsHakuta Ryunosuke, Hamada Tsuyoshi, Isayama Hiroyuki, Ishigaki Kazunaga, Kanai Sachiko, Kogure Hirofumi, Koike Kazuhiko, Mizuno Suguru, Nakai Yousuke, Nakamura Tomoka, Oyama Hiroki, Saito Kei, Saito Tomotaka, Sato Tatsuya, Suzuki Tatsunori, Tada Minoru, Takahara Naminatsu거트앤리버 소화기연관학회협의회 · Gut and Liver2020 · 제14권 제6호Present and Future of Endoscopic Ultrasound-Guided Tissue Acquisition in Solid Pancreatic TumorsJae Keun Park, Kwang Hyuck Lee대한소화기내시경학회 · Clinical Endoscopy2019 · 제52권 제6호How to optimize the diagnostic yield of endoscopic ultrasound-guided fine-needle sampling in solid pancreatic lesions from a technical perspective김홍주, Kim Nam Hee소화기인터벤션의학회 · International Journal of Gastrointestinal Intervention2023 · 제12권 제2호Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid LesionsAkeem Harris, Howard Wu, Ihab I. El Hajj, Mark A. Gromski, Melissa Randolph, Mohammad Al-Haddad, Sarah Reuss대한소화기내시경학회 · Clinical Endoscopy2018 · 제51권 제6호Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using a 20-Gauge Menghini Needle with a Lateral Forward Bevel and a 22-Gauge Franseen Needle: A Single-Center Large Cohort StudyAkiyoshi Kasuga, Masato Matsuyama, Masato Ozaka, Naoki Sasahira, Ryo Kanata, Takaaki Furukawa, Takafumi Mie, Takashi Sasaki, Tsuyoshi Takeda대한소화기내시경학회 · Clinical Endoscopy2021 · 제54권 제5호