본문 바로가기
KERD
논문KCI 등재

Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions

2

조회

0

다운로드

6

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remains the most common EUS-guided tissueacquisition technique. This study aimed to evaluate the performance of a new Franseen tip fine needle biopsy (FNB) device for EUSguidedsampling of solid lesions and compare it with the historical FNA technique. Methods: Acquire® 22 G FNB needle (Boston Scientific Co., Natick, MA, USA) was used for solid tumor sampling (Study group). Tissue was collected for rapid on-site evaluation, and touch and crush preparations were made. Historical EUS-FNA samples obtainedusing Expect® 22 G FNA needle (Boston Scientific Co.) were used as controls (Control group). All specimens were independentlyevaluated by two cytopathologists blinded to the formal cytopathological diagnosis. Results: Mean cell block histology scores were significantly higher (p=0.046) in the FNB group (51 samples) despite a significantlylower (p<0.001) mean number of passes compared to the FNA group (50 specimens). The overall diagnostic yields for the FNB vs. FNAgroups were 96% vs. 88%. The degree of tumor differentiation was adequately assessed in all cell block qualifying lesions in the FNBgroup. Two patients developed post-FNB abdominal pain. Conclusions: The new Franseen tip FNB device provides histologically superior and cytologically comparable specimens to thoseobtained by FNA, but with fewer passes.

Abstract

Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remains the most common EUS-guided tissueacquisition technique. This study aimed to evaluate the performance of a new Franseen tip fine needle biopsy (FNB) device for EUSguidedsampling of solid lesions and compare it with the historical FNA technique. Methods: Acquire® 22 G FNB needle (Boston Scientific Co., Natick, MA, USA) was used for solid tumor sampling (Study group). Tissue was collected for rapid on-site evaluation, and touch and crush preparations were made. Historical EUS-FNA samples obtainedusing Expect® 22 G FNA needle (Boston Scientific Co.) were used as controls (Control group). All specimens were independentlyevaluated by two cytopathologists blinded to the formal cytopathological diagnosis. Results: Mean cell block histology scores were significantly higher (p=0.046) in the FNB group (51 samples) despite a significantlylower (p<0.001) mean number of passes compared to the FNA group (50 specimens). The overall diagnostic yields for the FNB vs. FNAgroups were 96% vs. 88%. The degree of tumor differentiation was adequately assessed in all cell block qualifying lesions in the FNBgroup. Two patients developed post-FNB abdominal pain. Conclusions: The new Franseen tip FNB device provides histologically superior and cytologically comparable specimens to thoseobtained by FNA, but with fewer passes.

참고문헌 (23)

  1. Wani S, "EUS-guided tissue acquisition:an evidence-based approach (with videos)", Gastrointest Endosc, 80, pp.939~959 (2014)
  2. Dumonceau JM, "Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology:European Society of Gastrointestinal Endoscopy (ESGE)clinical guideline - updated January 2017", Endoscopy, 49, pp.695~714 (2017)
  3. Mohamadnejad M, "Increasing number of passes beyond 4 does not increase sensitivity of detection of pancreatic malignancy by endoscopic ultrasound-guided fine-needle aspiration", Clin Gastroenterol Hepatol, 15, pp.1071~1078 (2017)
  4. Rong L, "Factors affecting the diagnostic accuracy of endoscopic ultrasonography-guided fine-needle aspiration (EUS-FNA) for upper gastrointestinal submucosal or extraluminal solid mass lesions", Dig Endosc, 24, pp.358~363 (2012)
  5. Shield PW, "Rapid on-site evaluation of fine needle aspiration specimens by cytology scientists: a review of 3032 specimens", Cytopathology, 25, pp.322~329 (2014)
  6. Wani S, "The clinical impact of immediate on-site cytopathology evaluation during endoscopic ultrasound-guided fine needle aspiration of pancreatic masses: a prospective multicenter randomized controlled trial", Am J Gastroenterol, 110, pp.1429~1439 (2015)
  7. Savides TJ, "EUS-guided FNA diagnostic yield of malignancy in solid pancreatic masses: a benchmark for quality performance measurement", Gastrointest Endosc, 66, pp.277~282 (2007)
  8. Sepe PS, "EUS-guided FNA for the diagnosis of GI stromal cell tumors: sensitivity and cytologic yield", Gastrointest Endosc, 70, pp.254~261 (2009)
  9. Mekky MA, "Diagnostic utility of EUS-guided FNA in patients with gastric submucosal tumors", Gastrointest Endosc, 71, pp.913~919 (2010)
  10. Varadarajulu S, "Comparison of EUS-guided 19-gauge trucut needle biopsy with EUS-guided fine-needle aspiration", Endoscopy, 36, pp.397~401 (2004)
  11. Levy MJ, "Preliminary experience with an EUS-guided trucut biopsy needle compared with EUS-guided FNA", Gastrointest Endosc, 57, pp.101~106 (2003)
  12. DeWitt J, "Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study", Endosc Int Open, 3, pp.E471~E478 (2015)
  13. Bang JY, "A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition", Endoscopy, 48, pp.339~349 (2016)
  14. Cotton PB, "A lexicon for endoscopic adverse events: report of an ASGE workshop", Gastrointest Endosc, 71, pp.446~454 (2010)
  15. 방지영, "Procore and Flexible 19 Gauge Needle Can Replace Trucut Biopsy Needle?", Clinical Endoscopy, 46(5), pp.503~505 (2013), 대한소화기내시경학회
  16. Witt BL, "A comparative needle study:EUS-FNA procedures using the HD ProCore™ and EchoTip® 22-gauge needle types", Diagn Cytopathol, 41, pp.1069~1074 (2013)
  17. Nayar MK, "Comparison of the diagnostic performance of 2 core biopsy needles for EUS-guided tissue acquisition from solid pancreatic lesions", Gastrointest Endosc, 85, pp.1017~1024 (2017)
  18. Kandel P, "EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study", Gastrointest Endosc, 84, pp.1034~1039 (2016)
  19. Rodrigues-Pinto E, "Impact of EUS-guided fine-needle biopsy sampling with a new core needle on the need for onsite cytopathologic assessment: a preliminary study", Gastrointest Endosc, 84, pp.1040~1046 (2016)
  20. Bang JY, "Endoscopic ultrasonography-guided biopsy using a Franseen needle design: initial assessment", Dig Endosc, 29, pp.338~346 (2017)
  21. Mounzer R, "Interobserver agreement among cytopathologists in the evaluation of pancreatic endoscopic ultrasound-guided fine needle aspiration cytology specimens", Endosc Int Open, 4, pp.E812~E819 (2016)
  22. Hewitt MJ, "EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysis", Gastrointest Endosc, 75, pp.319~331 (2012)
  23. Aadam AA, "A randomized controlled cross-over trial and cost analysis comparing endoscopic ultrasound fine needle aspiration and fine needle biopsy", Endosc Int Open, 4, pp.E497~E505 (2016)

관련 논문AI추천

Endoscopic Ultrasound-Guided Tissue Acquisition by 22-Gauge Franseen and Standard Needles for Solid Pancreatic LesionsHakuta Ryunosuke, Hamada Tsuyoshi, Isayama Hiroyuki, Ishigaki Kazunaga, Kanai Sachiko, Kogure Hirofumi, Koike Kazuhiko, Mizuno Suguru, Nakai Yousuke, Nakamura Tomoka, Oyama Hiroki, Saito Kei, Saito Tomotaka, Sato Tatsuya, Suzuki Tatsunori, Tada Minoru, Takahara Naminatsu거트앤리버 소화기연관학회협의회 · Gut and Liver2020 · 제14권 제6호Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial배한익, 이반석, 장정식, 정민규, 조창민거트앤리버 소화기연관학회협의회 · Gut and Liver2017 · 제11권 제4호Modified Endoscopic Ultrasound Needle to Obtain Histological Core Tissue Samples: A Retrospective AnalysisArvind R. Murali, Chris Jensen, Henning Gerke, Jagpal S. Klair, Kaartik Soota, Munish Ashat, Rami El Abiad, Randhir Jesudoss, Sarika Gupta대한소화기내시경학회 · Clinical Endoscopy2020 · 제53권 제4호The diagnostic yield of specimens obtained from endoscopic ultrasound guided fine needle biopsy of solid masses with the AcquireTM needleArthur Kaffes, Ellie Skacel, James Kench, Mark Bonnichsen, Payal Saxena소화기인터벤션의학회 · International Journal of Gastrointestinal Intervention2020 · 제9권 제3호Comparison of the Diagnostic Yield of the Standard 22-Gauge Needle and the New 20-Gauge Forward-Bevel Core Biopsy Needle for Endoscopic Ultrasound-Guided Tissue Acquisition from Pancreatic LesionsHirotoshi Ishiwatari, Hiroyuki Matsubayashi, Hiroyuki Ono, Junya Sato, Keiko Sasaki, Kenichiro Imai, Kinichi Hotta, Kohei Takizawa, Masao Yoshida, Naomi Kakushima, Noboru Kawata, Sayo Ito, Shinya Fujie거트앤리버 소화기연관학회협의회 · Gut and Liver2019 · 제13권 제3호Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-AnalysisBenjamin D. Renelus, Daniel S. Jamorabo, Iman Boston, John M. Poneros, William M. Briggs대한소화기내시경학회 · Clinical Endoscopy2021 · 제54권 제2호

이 간행물의 다른 논문 (19건)