본문 바로가기
KERD
논문KCI 등재

Green flow injection spectrophotometric system for lead ion (II) evaluation in vegetables samples using new azo reagent

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류화학

초록

A new, sensitive, and reliable flow injection methodology was investigated for the determination of lead ion (II) in vegetables’ samples using a laboratory-prepared reagent 2-[(6-methoxy-2-benzothiazoly)azo]- 4-methoxy phenol (6-MBTAMP). Infrared spectroscopy, UV-visible spectrophotometry, Energy dispersive Xray spectroscopy (EDX), Elemental Analysis (CHN), nuclear magnetic resonance spectroscopy 1HNMR, and 13CNMR techniques were used to characterize the reagent and lead (II) complex. The method is based on lead ion (II) reacting with the reagent (6-MBTAMP) in a neutral solution to produce a green-red complex with a maximum absorbance at 670 nm. The optimum conditions, such as flow rate, lead ion (II) volume, reagent volume, medium pH, reagent concentration, and reaction coil length were thoroughly examined. The limits of detection (LOD) and quantification (LOQ) were determined to be 0.621 mg·L−1 and 2.069 mg·L−1, respectively, while Sandell's sensitivity was determined to be 0.345 μg·cm−2.

Abstract

A new, sensitive, and reliable flow injection methodology was investigated for the determination of lead ion (II) in vegetables’ samples using a laboratory-prepared reagent 2-[(6-methoxy-2-benzothiazoly)azo]- 4-methoxy phenol (6-MBTAMP). Infrared spectroscopy, UV-visible spectrophotometry, Energy dispersive Xray spectroscopy (EDX), Elemental Analysis (CHN), nuclear magnetic resonance spectroscopy 1HNMR, and 13CNMR techniques were used to characterize the reagent and lead (II) complex. The method is based on lead ion (II) reacting with the reagent (6-MBTAMP) in a neutral solution to produce a green-red complex with a maximum absorbance at 670 nm. The optimum conditions, such as flow rate, lead ion (II) volume, reagent volume, medium pH, reagent concentration, and reaction coil length were thoroughly examined. The limits of detection (LOD) and quantification (LOQ) were determined to be 0.621 mg·L−1 and 2.069 mg·L−1, respectively, while Sandell's sensitivity was determined to be 0.345 μg·cm−2.

참고문헌 (19)

  1. G. Ji, , J. Mater. Chem. A, 5(21), pp.10200~10205 (2017)
  2. D. Li, , J. Lumin, 216, pp.116711~ (2019)
  3. G. N. Abdel-Rahman, , J. Biol. Sci, 18(3), pp.135~143 (2018)
  4. M. J. Ahmed, , Chem. Sci. Int. J, 26(2), pp.1~19 (2019)
  5. H. Moradi, , Iran. J. Chem. Chem. Eng. (IJCCE), 36(3), pp.97~106 (2017)
  6. J. Q. Sun, , Advanced Mater. Res, 1030-1032, pp.301~304 (2014)
  7. T. Borahan, , Food Chem, 299, pp.125065~ (2019)
  8. J. Sun, , Adv. Mater. Res., 1030-1032, pp.301~304 (2014)
  9. P. Ncube, , Water SA, 40(1), pp.175~182 (2014)
  10. M. Yuan, , Microchim. Acta, 184(5), pp.1397~1403 (2017)
  11. M. S. D. Nezio, , Anal. Letters, 39(6), pp.1211~1228 (2006)
  12. J. Klamtet, , NU Int. J. Sci, 4(2), pp.122~131 (2007)
  13. R. Rodríguez-Maese, , Microchem. J, 154, pp.104550~ (2020)
  14. W. Ruengsitagoon, , Talanta, 81(1-2), pp.709~713 (2010)
  15. M. S. D. Nezio, , Talanta, 63(2), pp.405~409 (2004)
  16. M. H. Habibollahi, , J. Sci. Food Agric, 99(2), pp.656~665 (2019)
  17. J. M. M. Al-Zinkee, , J. of Pharmaceutical Sci. and Res, 11(1), pp.98~103 (2019)
  18. K. J. Ali, , Int. J. Chem. Sci, 14(3), pp.1385~1404 (2016)
  19. K. J. Ali, , J. Chem. Pharm. Sci, 9(4), pp.2915~2923 (2016)

관련 논문AI추천

A new merging-zone flow injection system for the quantification of ferrous and ferric ions in aqueous solution and sludge of wastewaterAhmed Saleh Farhood, Dakhil Nassir Taha한국분석과학회 · 분석과학2022 · 제35권 제5호Determination of Cadmium Ions by Designing an Optode Based on Immobilization of Dithizone on a Triacetylecelluose Membrane in Polluted Soil and Water SamplesFatemeh Kazempourfard, Hossein Tavallali대한화학회 · 대한화학회지2009 · 제53권 제2호Detection of Heavy Metal Ions in Aqueous Solution Using Direct Dye Chemosensors고영일, 배진석, 허은영한국염색가공학회 · 한국염색가공학회지2009 · 제21권 제5호Simultaneous Spectrophotometric Determination of Copper, Nickel, and Zinc Using 1-(2-Thiazolylazo)-2-Naphthol in the Presence of Triton X-100 Using Chemometric MethodsKah Hin Low, Mhd. Radzi Abas, Misni Misran, Mustafa Ali Mohd, Sharifuddin Md. Zain대한화학회 · 대한화학회지2009 · 제53권 제6호Catalytic Spectrophotometry for the Determination of Manganese at Trace Levels by a Novel Indicator ReactionOsman Çaylak, Ramazan Gürkan대한화학회 · 대한화학회지2010 · 제54권 제5호Application of Polyurethane Foam Loaded with a Schiff Base Ligand for Determination of Trace Amounts of Copper in Water Samples by Flame Atomic Absorption SpectroscopyAbbas Ali Zamani, Mahdieh Koorehpazan Moftakhar, Mohammad Reza Yaftian, Samaneh Nahaei대한화학회 · 대한화학회지2014 · 제58권 제3호

이 간행물의 다른 논문 (5건)