Application of Polyurethane Foam Loaded with a Schiff Base Ligand for Determination of Trace Amounts of Copper in Water Samples by Flame Atomic Absorption Spectroscopy
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
A column solid phase extraction procedure based on modified polyurethane foam (PUF) by a newly synthesized Schiff base ionophore, named 2,2'-{iminobis[propane-3,1-diylnitrilo(1E)prop-1-yl-1-ylidene]}diphenol, was developed for preconcentration step of trace amounts determination of copper ions in water samples by atomic absorption flame spectroscopy. The influence of parameters on the adsorption process such as sample pH, amount of modified PUF packed in the column, type and volume of stripping reagent and its flow rate were investigated and optimized. Under optimum experimental conditions, the calibration graph was linear in a relatively wide range (0.005-210 μg/ml) with a limit of detection 0.002 μg/ml of copper. The proposed method allows achieving to a concentration factor of >133. The capacity of a column (1.6 cm i.d.) packed by 6 g of PUF modified by 12 mg of the Schiff base was found to be 247.7 (± 2.1) μg of copper. It was found that the adsorption process was highly selective towards copper ions with respect to some associated metal ions. The presented procedure was successfully applied for determination of copper in some water samples.
Abstract
A column solid phase extraction procedure based on modified polyurethane foam (PUF) by a newly synthesized Schiff base ionophore, named 2,2'-{iminobis[propane-3,1-diylnitrilo(1E)prop-1-yl-1-ylidene]}diphenol, was developed for preconcentration step of trace amounts determination of copper ions in water samples by atomic absorption flame spectroscopy. The influence of parameters on the adsorption process such as sample pH, amount of modified PUF packed in the column, type and volume of stripping reagent and its flow rate were investigated and optimized. Under optimum experimental conditions, the calibration graph was linear in a relatively wide range (0.005-210 μg/ml) with a limit of detection 0.002 μg/ml of copper. The proposed method allows achieving to a concentration factor of >133. The capacity of a column (1.6 cm i.d.) packed by 6 g of PUF modified by 12 mg of the Schiff base was found to be 247.7 (± 2.1) μg of copper. It was found that the adsorption process was highly selective towards copper ions with respect to some associated metal ions. The presented procedure was successfully applied for determination of copper in some water samples.
참고문헌 (26)
- Pesavento, M, , Anal. Chim. Acta, 631, pp.129~ (2009)
- Pena-Pereira, F, , Spectrochim. Acta, B64, pp.1~ (2009)
- Camel, V, , Spectrochim. Acta, B58, pp.1177~ (2003)
- de Almeida Bezerra, M, , Appl. Spect. Rev, 40, pp.269~ (2005)
- Bispo, M. S, , Spectrochim. Acta, B60, pp.663~ (2005)
- Alfassi, Z. B, "Preconcentration Techniques" (1992), CRC Press
- Lemos, V. A, , Spectrochim. Acta, B62, pp.4~ (2007)
- Bowen, H. T. M, , J. Chem. Soc. A, pp.1082~ (1970)
- Anthemidis, A. N, , Talanta, 58, pp.831~ (2002)
- Sant, Ana, O. D, , J. Brazil. Chem. Soc, 5, pp.728~ (2003)
- de Almeida, G. N, , J. Colloid Interf. Sci, 315, pp.63~ (2007)
- Lemos, V. A, , Anal. Chim. Acta, 481, pp.283~ (2003)
- Gama, E. M, , J. Hazard. Mater, B136, pp.757~ (2006)
- Moawed, E. A, , React. Funct. Polym, 66, pp.720~ (2006)
- Burham, N, , Anal. Chim. Acta, 579, pp.193~ (2006)
- Lemos, V. A, , J. Food Composition and Analysis, 23, pp.277~ (2010)
- Emadi, D, , Turk. J. Chem, 31, pp.423~ (2007)
- Sadeghi, S, , Sens. Actuator, B114, pp.928~ (2006)
- Shemirani, F, , Anal. Sci, 19, pp.1453~ (2003)
- Kara, D, , Microchem. J, 71, pp.29~ (2002)
- Fathi, S. A. M, , Hazard. Mater, 164, pp.133~ (2009)
- Hancock, R. D, , Chem. Rev, 89, pp.1875~ (1989)
- Fathi, S. A. M, , J. Anal. Chem, 65, pp.614~ (2010)
- Parinejad, M, , Iran. J. Chem. Chem. Eng, 28, pp.85~ (2009)
- Fathi, S. A. M, , J. Colloid Interface Sci, 334, pp.167~ (2009)
- Fathi, S. A. M, , Sep. Purif. Technol, 64, pp.1178~ (2008)
