본문 바로가기
KERD
논문KCI 등재

Simultaneous Spectrophotometric Determination of Copper, Nickel, and Zinc Using 1-(2-Thiazolylazo)-2-Naphthol in the Presence of Triton X-100 Using Chemometric Methods

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류화학

초록

Multivariate models were developed for the simultaneous spectrophotometric determination of copper (II), nickel (II) and zinc (II) in water with 1-(2-thiazolylazo)-2-naphthol as chromogenic reagent in the presence of Triton X-100. To overcome the drawback of spectral interferences, principal component regression (PCR) and partial least square (PLS) multivariate calibration approaches were applied. Performances were validated with several test sets, and their results were then compared. In general, no significant difference in analytical performance between PLS and PCR models. The root mean square error of prediction (RMSEP) using three components for Cu2+, Ni2+ and Zn2+ were 0.018, 0.010, 0.011 ppm, respectively. Figures of merit such as sensitivity, analytical sensitivity, limit of detection (LOD) were also estimated. High reliability was achieved when the proposed procedure was applied to simultaneous determination of Cu2+, Ni2+ and Zn2+ in synthetic mixture and tap water.

Abstract

Multivariate models were developed for the simultaneous spectrophotometric determination of copper (II), nickel (II) and zinc (II) in water with 1-(2-thiazolylazo)-2-naphthol as chromogenic reagent in the presence of Triton X-100. To overcome the drawback of spectral interferences, principal component regression (PCR) and partial least square (PLS) multivariate calibration approaches were applied. Performances were validated with several test sets, and their results were then compared. In general, no significant difference in analytical performance between PLS and PCR models. The root mean square error of prediction (RMSEP) using three components for Cu2+, Ni2+ and Zn2+ were 0.018, 0.010, 0.011 ppm, respectively. Figures of merit such as sensitivity, analytical sensitivity, limit of detection (LOD) were also estimated. High reliability was achieved when the proposed procedure was applied to simultaneous determination of Cu2+, Ni2+ and Zn2+ in synthetic mixture and tap water.

참고문헌 (50)

  1. Ministry of Science, "Technology and Environment,Malaysia, Kuala Lumpur Environmental Quality(Sewage Industrial Effluent) Regulations", ~ (1979)
  2. Sánchez, E., , Ecological Indicators, 7(315) (2007)
  3. Uluozlu, O. D., , Food Chemistry, 104(2), pp.835~ (2007)
  4. Celik, U, , J. Food Control, 18(258) (2007)
  5. Samecka-Cymerman, A., , Ecotoxicology and Environmental Safety, 59(64) (2004)
  6. Smuda, J., , Journal of Geochemical Exploration, 92(2), pp.97~ (2007)
  7. Matlock, M. M., , A.Advances in Environmental Research, 7(2), pp.495~ (2003)
  8. Divrikli, U, , Journal of Hazardous Materials, 145(3), pp.459~ (2007)
  9. Venkatesh, G., , Talanta, 67(1), pp.187~ (2005)
  10. Gurnani, V., , Analytica Chimica Acta, 485(2), pp.221~ (2003)
  11. Matoso, E, , Talanta, 60(6), pp.1105~ (2003)
  12. Eskandari, H., , Turkey Journal of Chemistry, 30(49) (2006)
  13. Khoshayand, M. R., , Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 70(3), pp.491~ (2008)
  14. Ghavami, R, , Spectrochimica Acta Part A, 70(4), pp.824~ (2008)
  15. Abdollahi, H., , Talanta, 59(6), pp.1141~ (2003)
  16. Raimundo, Jr. I. M., , Sensors and Actuators B, 90(189) (2003)
  17. Niazi, A., , Chinese Chemical Letters, 19(860) (2008)
  18. Moneeb, M. S, , Talanta, 70(5), pp.1035~ (2006)
  19. Pettas, I. A, , Analytica Chimica Acta, 491(2), pp.219~ (2003)
  20. Ni, Y., , Analytica Chimica Acta, 463(2), pp.305~ (2002)
  21. Goodarzi, M., , Spectrochimica Acta Part A, 73(4), pp.608~ (2009)
  22. Teixeira, L. S. G., , Journal of Brazilian Chemical Society, 13(1), pp.54~ (2002)
  23. Lemos, V. A., , Microchimica Acta, 158(189) (2007)
  24. Baliza, P. X., , Talanta, 79(1), pp.2~ (2009)
  25. Sánchez Rojas, F., , Analytica ChimicaActa, 635(1), pp.22~ (2009)
  26. Lee, S. K., , Bulletin of Korean ChemicalSociety, 22(5), pp.463~ (2001)
  27. Omar, M. M., , Spectrochimica ActaPart A, 61(929) (2007)
  28. Teixeira, L. S. G., , Talanta, 71(1507) (2007)
  29. Mehta, S. K., , J.Electronic Journal of Agricultural Food Chemistry, 3(6), pp.784~ (2004)
  30. Zaporozhets, O., , Talanta, 49(899) (1999)
  31. Watanabe, H., , Japan analyst, 25(1), pp.35~ (1976)
  32. Petrucelli, G. A., , Talanta, 71(2), pp.620~ (2007)
  33. Collado, M. S, , Talanta, 52(5), pp.909~ (2000)
  34. Ostra, M., , Analyst, 133(532) (2008)
  35. Espinosa-Mansilla, A., , Talanta, 62(853) (2004)
  36. Marsili, N. R., , Analytical and Bioanalytical Chemistry, 376(126) (2003)
  37. Iñón, F. A., , Analytica Chimica Acta, 489(1), pp.59~ (2003)
  38. Samadi-Maybodi,A., , Spectrochimica Acta Part A, 70(5), pp.1167~ (2008)
  39. Gil García, M. D., , Journal of Chromatography A, 1179(115) (2008)
  40. Brás, L. P., , Chemometrics and Intelligent Laboratory Systems, 75(91) (2005)
  41. Goicoechea, H. C., , Analytical Chemistry, 71(19), pp.4361~ (1999)
  42. Boquk, R, , Chemometrics and Intelligent Laboratory Systems, 32(11) (1996)
  43. Visser, A. E., , Journal of Chromatography B, 743(107) (2000)
  44. Qu, N., , Spectrochimica Acta Part A, 70(5) (2008)
  45. Hadad, G. M., , M.Spectrochimica Acta Part A, 70(3), pp.655~ (2008)
  46. Şxahin, S, , Dyes and Pigments, 73(368) (2007)
  47. Jha, S. N., , BiosystemsEngineering, 91(2), pp.157~ (2005)
  48. Lammertyn, J, , J. Transactions of the ASAE, 41(1089) (1998)
  49. Rodriguez-Nogales, J, , M. Food Chemistry, 98(782) (2006)
  50. Kuswandi, B., , Journal of EnvironmentalMonitoring, 1(109) (1999)

관련 논문AI추천

이 간행물의 다른 논문 (26건)