To compare the image quality of high resolution CT scan of temporal bone reconstructed using novel adaptive statistical iterative reconstruction-v technique with conventional filter back projection reconstruction technique

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

To compare the image quality of high resolution CT scan of temporal bone reconstruction using a novel adaptive iterative reconstruction-V (IR) technique with conventional filter back projection technique. The objective (mean image noise, contrast-to-noise ratio (CNR) for the temporal bone and the mean attenuation value of soft tissue) and subjective image parameters (image noise, image contrast, overall visibility of temporal bone/soft issue visibility of small structures and overall diagnostic confidence) were assessed. Eighteen patient underwent standard protocol of CT temporal bone at our institution. The same raw data were reconstructed using FBP and ASIR 20 %, ASIR 40 %, ASIR 60 %, ASIR 80 %.result shows that image measurements revealed significantly less noise in the soft tissue than bone attenuation value for the ASIR (p-value<0.05). Used Wilcoxon signed rank test. Filter back projection and ASIR Bone with various percentages but there no significant difference in two methods (p < 0.05). Comparing Filter back projection Soft Tissue and ASIR Soft Tissue, there is significant with in ASIRSoft Tissue percentages various percentages and also it is better than FBP (p < 0.05). Note Data are indicated Median and IQR=Interquartile range (25th and 75th percentile). It is statistically significant difference of increasing percentage of ASIR percentage of soft tissue. This study concluded that ASIR shows superior reduction of noise and improved image q

Abstract

To compare the image quality of high resolution CT scan of temporal bone reconstruction using a novel adaptive iterative reconstruction-V (IR) technique with conventional filter back projection technique. The objective (mean image noise, contrast-to-noise ratio (CNR) for the temporal bone and the mean attenuation value of soft tissue) and subjective image parameters (image noise, image contrast, overall visibility of temporal bone/soft issue visibility of small structures and overall diagnostic confidence) were assessed. Eighteen patient underwent standard protocol of CT temporal bone at our institution. The same raw data were reconstructed using FBP and ASIR 20 %, ASIR 40 %, ASIR 60 %, ASIR 80 %.result shows that image measurements revealed significantly less noise in the soft tissue than bone attenuation value for the ASIR (p-value<0.05). Used Wilcoxon signed rank test. Filter back projection and ASIR Bone with various percentages but there no significant difference in two methods (p < 0.05). Comparing Filter back projection Soft Tissue and ASIR Soft Tissue, there is significant with in ASIRSoft Tissue percentages various percentages and also it is better than FBP (p < 0.05). Note Data are indicated Median and IQR=Interquartile range (25th and 75th percentile). It is statistically significant difference of increasing percentage of ASIR percentage of soft tissue. This study concluded that ASIR shows superior reduction of noise and improved image q

관련 논문AI추천

Evaluation of Performance and No-reference-based Quality for CT Image with ADMIRE Iterative Reconstruction Parameters : A Pilot Study강성현, 김하진, 박보민, 서유진, 심지나, 이영진, 임세원대한방사선과학회 · Journal of Radiological Science and Technology2024 · 제47권 제3호Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography김기정, 문태준, 이혜남대한방사선과학회 · Journal of Radiological Science and Technology2017 · 제40권 제2호Temporal Bone Imaging Opportunities With Ultra-High-Resolution Computed TomographyLoureiro Rafael Maffei, Soares Carolina Ribeiro, Sumi Daniel Vaccaro대한청각학회 · Journal of Audiology & Otology2023 · 제27권 제1호Possibility and Limitation of Micro-CT in Cochlear Imaging of Rat최철희한국청각언어재활학회 · Audiology and Speech Research2012 · 제8권 제1호전산화단층촬영에서 관전압과 관전류, 통계적 반복재구성법에 따른 화질과 피폭선량김정훈, 박재윤, 이용기, 차상영, 최재호대한방사선과학회 · Journal of Radiological Science and Technology2017 · 제40권 제3호CT 장비별 관전압의 변화에 따른 노이즈, SNR 평가 - 자동노출제어방법과 수동노출제어방법 비교 -곽종길, 김미현, 동경래, 문일봉, 박상원, 성호진(사)한국방사선산업학회 · 방사선산업학회지2018 · 제12권 제3호

이 간행물의 다른 논문 (59건)