Factors associated with unsuccessful pessary fitting and reasons for discontinuation in Korean women with pelvic organ prolapse
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Objective: To identify the factors associated with unsuccessful pessary fitting and reasons for pessary discontinuation in Korean women with pelvic organ prolapse (POP). Methods: The medical records of 234 patients who underwent pessary fitting for the management of symptomatic POP were retrospectively reviewed. A ring pessary with or without support was used. Successful pessary fitting was defined as the ability to wear a pessary for 2 weeks without any discomfort. Factors associated with unsuccessful pessary fitting were determined using a multivariable logistic regression analysis. A Kaplan-Meier survival curve was obtained to examine the probability of continuing pessary use over the follow-up period. The reasons for the discontinuation of pessary were identified. Results: Two-hundred-and-twenty-five women were included in the analysis. The rate of unsuccessful pessary fitting was 40%. Prior hysterectomy (odds ratio [OR], 4.13; 95% confidence interval [CI], 1.81-9.42) and POP quantification stage III-IV (OR, 2.49; 95% CI, 1.28-4.85) were independent risk factors for unsuccessful pessary fitting. Among the patients with successful pessary fitting, the median time to discontinuation of pessary use was 4 years. The most common causes of discontinued use were vaginal erosion (45.3%) and urinary incontinence (26.5%). Conclusion: Patients with a history of hysterectomy and advanced-stage POP are at risk for an unsuccessful fitting of the ring pessary. Vaginal erosion is the main reason for discontinued use among patients with successful pessary fitting.
Abstract
Objective: To identify the factors associated with unsuccessful pessary fitting and reasons for pessary discontinuation in Korean women with pelvic organ prolapse (POP). Methods: The medical records of 234 patients who underwent pessary fitting for the management of symptomatic POP were retrospectively reviewed. A ring pessary with or without support was used. Successful pessary fitting was defined as the ability to wear a pessary for 2 weeks without any discomfort. Factors associated with unsuccessful pessary fitting were determined using a multivariable logistic regression analysis. A Kaplan-Meier survival curve was obtained to examine the probability of continuing pessary use over the follow-up period. The reasons for the discontinuation of pessary were identified. Results: Two-hundred-and-twenty-five women were included in the analysis. The rate of unsuccessful pessary fitting was 40%. Prior hysterectomy (odds ratio [OR], 4.13; 95% confidence interval [CI], 1.81-9.42) and POP quantification stage III-IV (OR, 2.49; 95% CI, 1.28-4.85) were independent risk factors for unsuccessful pessary fitting. Among the patients with successful pessary fitting, the median time to discontinuation of pessary use was 4 years. The most common causes of discontinued use were vaginal erosion (45.3%) and urinary incontinence (26.5%). Conclusion: Patients with a history of hysterectomy and advanced-stage POP are at risk for an unsuccessful fitting of the ring pessary. Vaginal erosion is the main reason for discontinued use among patients with successful pessary fitting.
참고문헌 (22)
- Hagen S, "Conservative prevention and management of pelvic organ prolapse in women", Cochrane Database Syst Rev, (12), pp.CD003882~ (2011)
- Nygaard I, "Prevalence of symptomatic pelvic floor disorders in US women", JAMA, 300, pp.1311~1316 (2008)
- Lone F, "One-year prospective comparison of vaginal pessaries and surgery for pelvic organ prolapse using the validated ICIQ-VS and ICIQ-UI(SF)questionnaires", Int Urogynecol J, 26, pp.1305~1312 (2015)
- Sung VW, "Patient-reported goal attainment and comprehensive functioning outcomes after surgery compared with pessary for pelvic organ prolapse", Am J Obstet Gynecol, 215, pp.659.e1~659.e7 (2016)
- Bai SW, "Survey of the characteristics and satisfaction degree of the patients using a pessary", Int Urogynecol J Pelvic Floor Dysfunct, 16, pp.182~186 (2005)
- CundiffGW, "A survey of pessary use by members of the American Urogynecologic Society", Obstet Gynecol, 95(6Pt 1), pp.931~935 (2000)
- Yuk JS, "The prevalence and treatment pattern of clinically diagnosed pelvic organ prolapse : a Korean National Health Insurance Database-based cross-sectional study 2009-2015", Sci Rep, 8, pp.1334~ (2018)
- Panman CM, "Predictors of unsuccessful pessary fitting in women with prolapse : a cross-sectional study in general practice", Int Urogynecol J, 28, pp.307~313 (2017)
- Fernando RJ, "Effect of vaginal pessaries on symptoms associated with pelvic organ prolapse", Obstet Gynecol, 108, pp.93~99 (2006)
- Mao M, "Predictors for unsuccessful pessary fitting in women with symptomatic pelvic organ prolapse : a prospective study", BJOG, 125, pp.1434~1440 (2018)
- Mutone MF, "Factors which influence the short-term success of pessary management of pelvic organ prolapse", Am J Obstet Gynecol, 193, pp.89~94 (2005)
- Ma C, "Factors associated with pessary fitting in women with symptomatic pelvic organ prolapse : a large prospective cohort study", Neurourol Urodyn, 39, pp.2238~2245 (2020)
- Markle D, "Patient characteristics associated with a successful pessary fitting", Female Pelvic Med Reconstr Surg, 17, pp.249~252 (2011)
- Clemons JL, "Risk factors associated with an unsuccessful pessary fitting trial in women with pelvic organ prolapse", Am J Obstet Gynecol, 190, pp.345~350 (2004)
- Lamers BH, "Pessary treatment for pelvic organ prolapse and health-related quality of life : a review", Int Urogynecol J, 22, pp.637~644 (2011)
- Bump RC, "The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction", Am J Obstet Gynecol, 175, pp.10~17 (1996)
- Culligan PJ, "Nonsurgical management of pelvic organ prolapse", Obstet Gynecol, 119, pp.852~860 (2012)
- Ding J, "Which factors should be considered in choosing pessary type and size for pelvic organ prolapse patients in a fitting trial?", Int Urogynecol J, 27, pp.1867~1871 (2016)
- Broens-Oostveen MC, "Genital prolapse; treatment and course in four general practices", Ned Tijdschr Geneeskd, 148, pp.1444~1448 (2004)
- Sarma S, "Long-term vaginal ring pessary use : discontinuation rates and adverse events", BJOG, 116, pp.1715~1721 (2009)
- Lone F, "A 5-year prospective study of vaginal pessary use for pelvic organ prolapse", Int J Gynaecol Obstet, 114, pp.56~59 (2011)
- Abdulaziz M, "An integrative review and severity classification of complications related to pessary use in the treatment of female pelvic organ prolapse", Can Urol Assoc J, 9, pp.E400~E406 (2015)
