본문 바로가기
KERD
논문KCI 등재

Factors associated with unsuccessful pessary fitting and reasons for discontinuation in Korean women with pelvic organ prolapse

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류산부인과학

초록

Objective: To identify the factors associated with unsuccessful pessary fitting and reasons for pessary discontinuation in Korean women with pelvic organ prolapse (POP). Methods: The medical records of 234 patients who underwent pessary fitting for the management of symptomatic POP were retrospectively reviewed. A ring pessary with or without support was used. Successful pessary fitting was defined as the ability to wear a pessary for 2 weeks without any discomfort. Factors associated with unsuccessful pessary fitting were determined using a multivariable logistic regression analysis. A Kaplan-Meier survival curve was obtained to examine the probability of continuing pessary use over the follow-up period. The reasons for the discontinuation of pessary were identified. Results: Two-hundred-and-twenty-five women were included in the analysis. The rate of unsuccessful pessary fitting was 40%. Prior hysterectomy (odds ratio [OR], 4.13; 95% confidence interval [CI], 1.81-9.42) and POP quantification stage III-IV (OR, 2.49; 95% CI, 1.28-4.85) were independent risk factors for unsuccessful pessary fitting. Among the patients with successful pessary fitting, the median time to discontinuation of pessary use was 4 years. The most common causes of discontinued use were vaginal erosion (45.3%) and urinary incontinence (26.5%). Conclusion: Patients with a history of hysterectomy and advanced-stage POP are at risk for an unsuccessful fitting of the ring pessary. Vaginal erosion is the main reason for discontinued use among patients with successful pessary fitting.

Abstract

Objective: To identify the factors associated with unsuccessful pessary fitting and reasons for pessary discontinuation in Korean women with pelvic organ prolapse (POP). Methods: The medical records of 234 patients who underwent pessary fitting for the management of symptomatic POP were retrospectively reviewed. A ring pessary with or without support was used. Successful pessary fitting was defined as the ability to wear a pessary for 2 weeks without any discomfort. Factors associated with unsuccessful pessary fitting were determined using a multivariable logistic regression analysis. A Kaplan-Meier survival curve was obtained to examine the probability of continuing pessary use over the follow-up period. The reasons for the discontinuation of pessary were identified. Results: Two-hundred-and-twenty-five women were included in the analysis. The rate of unsuccessful pessary fitting was 40%. Prior hysterectomy (odds ratio [OR], 4.13; 95% confidence interval [CI], 1.81-9.42) and POP quantification stage III-IV (OR, 2.49; 95% CI, 1.28-4.85) were independent risk factors for unsuccessful pessary fitting. Among the patients with successful pessary fitting, the median time to discontinuation of pessary use was 4 years. The most common causes of discontinued use were vaginal erosion (45.3%) and urinary incontinence (26.5%). Conclusion: Patients with a history of hysterectomy and advanced-stage POP are at risk for an unsuccessful fitting of the ring pessary. Vaginal erosion is the main reason for discontinued use among patients with successful pessary fitting.

참고문헌 (22)

  1. Hagen S, "Conservative prevention and management of pelvic organ prolapse in women", Cochrane Database Syst Rev, (12), pp.CD003882~ (2011)
  2. Nygaard I, "Prevalence of symptomatic pelvic floor disorders in US women", JAMA, 300, pp.1311~1316 (2008)
  3. Lone F, "One-year prospective comparison of vaginal pessaries and surgery for pelvic organ prolapse using the validated ICIQ-VS and ICIQ-UI(SF)questionnaires", Int Urogynecol J, 26, pp.1305~1312 (2015)
  4. Sung VW, "Patient-reported goal attainment and comprehensive functioning outcomes after surgery compared with pessary for pelvic organ prolapse", Am J Obstet Gynecol, 215, pp.659.e1~659.e7 (2016)
  5. Bai SW, "Survey of the characteristics and satisfaction degree of the patients using a pessary", Int Urogynecol J Pelvic Floor Dysfunct, 16, pp.182~186 (2005)
  6. CundiffGW, "A survey of pessary use by members of the American Urogynecologic Society", Obstet Gynecol, 95(6Pt 1), pp.931~935 (2000)
  7. Yuk JS, "The prevalence and treatment pattern of clinically diagnosed pelvic organ prolapse : a Korean National Health Insurance Database-based cross-sectional study 2009-2015", Sci Rep, 8, pp.1334~ (2018)
  8. Panman CM, "Predictors of unsuccessful pessary fitting in women with prolapse : a cross-sectional study in general practice", Int Urogynecol J, 28, pp.307~313 (2017)
  9. Fernando RJ, "Effect of vaginal pessaries on symptoms associated with pelvic organ prolapse", Obstet Gynecol, 108, pp.93~99 (2006)
  10. Mao M, "Predictors for unsuccessful pessary fitting in women with symptomatic pelvic organ prolapse : a prospective study", BJOG, 125, pp.1434~1440 (2018)
  11. Mutone MF, "Factors which influence the short-term success of pessary management of pelvic organ prolapse", Am J Obstet Gynecol, 193, pp.89~94 (2005)
  12. Ma C, "Factors associated with pessary fitting in women with symptomatic pelvic organ prolapse : a large prospective cohort study", Neurourol Urodyn, 39, pp.2238~2245 (2020)
  13. Markle D, "Patient characteristics associated with a successful pessary fitting", Female Pelvic Med Reconstr Surg, 17, pp.249~252 (2011)
  14. Clemons JL, "Risk factors associated with an unsuccessful pessary fitting trial in women with pelvic organ prolapse", Am J Obstet Gynecol, 190, pp.345~350 (2004)
  15. Lamers BH, "Pessary treatment for pelvic organ prolapse and health-related quality of life : a review", Int Urogynecol J, 22, pp.637~644 (2011)
  16. Bump RC, "The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction", Am J Obstet Gynecol, 175, pp.10~17 (1996)
  17. Culligan PJ, "Nonsurgical management of pelvic organ prolapse", Obstet Gynecol, 119, pp.852~860 (2012)
  18. Ding J, "Which factors should be considered in choosing pessary type and size for pelvic organ prolapse patients in a fitting trial?", Int Urogynecol J, 27, pp.1867~1871 (2016)
  19. Broens-Oostveen MC, "Genital prolapse; treatment and course in four general practices", Ned Tijdschr Geneeskd, 148, pp.1444~1448 (2004)
  20. Sarma S, "Long-term vaginal ring pessary use : discontinuation rates and adverse events", BJOG, 116, pp.1715~1721 (2009)
  21. Lone F, "A 5-year prospective study of vaginal pessary use for pelvic organ prolapse", Int J Gynaecol Obstet, 114, pp.56~59 (2011)
  22. Abdulaziz M, "An integrative review and severity classification of complications related to pessary use in the treatment of female pelvic organ prolapse", Can Urol Assoc J, 9, pp.E400~E406 (2015)

관련 논문AI추천

Correlation between obesity and pelvic organ prolapse in Korean women김보혜, 김현철, 나은덕, 이수빈대한산부인과학회 · Obstetrics & Gynecology Science2020 · 제63권 제6호Outcomes of vaginal hysterectomy combined with anterior and posterior colporrhaphy for pelvic organ prolapse: a single center retrospective study이사라, Hee Dong Chae, Ju Hee Kim, So Young Lee, Sung Hoon Kim, Yoon Kyung Shin대한산부인과학회 · Obstetrics & Gynecology Science2022 · 제65권 제1호The association of pelvic organ prolapse severity and improvement in overactive bladder symptoms after surgery for pelvic organ prolapse김미선, 김현철, 나은덕, 이지훈, 장지현대한산부인과학회 · Obstetrics & Gynecology Science2016 · 제59권 제3호A clinical study on the trocar-guided mesh repair system for pelvic organ prolapse surgery김경아, 김경진, 문정범, 박슬기, 이주향, 홍상기대한산부인과학회 · Obstetrics & Gynecology Science2016 · 제59권 제3호Comparison of midurethral sling outcomes with and without concomitant prolapse repair김세광, 김수림, 배상욱, 한이정대한산부인과학회 · Obstetrics & Gynecology Science2014 · 제57권 제01호EFFECTIVE PARAMETERS OF URODYNAMIC STUDY BEFORE PELVIC ORGAN PROLAPSE SURGERY AND VALIDATION OF CONCOMITANT SURGERY ON URINARY OUTCOMES: RETROSPECTIVE COHORT STUDY김세광, 김수림, 문여정, 배상욱, 조주현대한산부인과학회 · Obstetrics & Gynecology Science2012 · 제55권 제04호

이 간행물의 다른 논문 (11건)