초록
A newly developed short double-balloon enteroscope with a working channel enlarged to a diameter of 3.2 mm is a novel innovation in stent placement for patients with surgically altered anatomies. Herein, we report three patients in whom this new scope contributed to an efficient technique and ideal treatment. In the first case, the double guidewire technique was efficient and effective for multiple stent placements. In the second case, covered self-expandable metal stent (SEMS) placement, which is the standard treatment for malignant biliary obstruction, could be performed in a technologically sound and safe manner. In the third case, SEMS placement was performed as palliative treatment for malignant afferent-loop obstruction; this procedure could be performed soundly and safely using the through-the-scope technique. The wider working channel of this new scope also facilitates a smoother accessory insertion and high suction performance, which reduces procedure time and stress on endoscopists. Furthermore, this new scope, which has advanced force transmission, adaptive bending, and a smaller turning radius, is expected to be highly successful in both diagnosis and therapy for various digestive diseases in patients with surgically altered anatomies.
Abstract
A newly developed short double-balloon enteroscope with a working channel enlarged to a diameter of 3.2 mm is a novel innovation in stent placement for patients with surgically altered anatomies. Herein, we report three patients in whom this new scope contributed to an efficient technique and ideal treatment. In the first case, the double guidewire technique was efficient and effective for multiple stent placements. In the second case, covered self-expandable metal stent (SEMS) placement, which is the standard treatment for malignant biliary obstruction, could be performed in a technologically sound and safe manner. In the third case, SEMS placement was performed as palliative treatment for malignant afferent-loop obstruction; this procedure could be performed soundly and safely using the through-the-scope technique. The wider working channel of this new scope also facilitates a smoother accessory insertion and high suction performance, which reduces procedure time and stress on endoscopists. Furthermore, this new scope, which has advanced force transmission, adaptive bending, and a smaller turning radius, is expected to be highly successful in both diagnosis and therapy for various digestive diseases in patients with surgically altered anatomies.
참고문헌 (9)
- Sakakihara I, "Double-balloon enteroscopy for choledochojejunal anastomotic stenosis after hepato-biliarypancreatic operation", Dig Endosc, 27, pp.146~154 (2015)
- Itoi T, "Single-balloon enteroscopy-assisted ERCP in patients with Billroth II gastrectomy or Roux-en-Y anastomosis (with video)", Am J Gastroenterol, 105, pp.93~99 (2010)
- 소재승, "Single Balloon Enteroscopy-Assisted Endoscopic Retrograde Cholangiopancreatography in Patients Who Underwent a Gastrectomy with Roux-en-Y Anastomosis: Six Cases from a Single Center", Clinical Endoscopy, 48(5), pp.452~457 (2015), 대한소화기내시경학회
- Tsutsumi K, "A novel technique for partial stent-in-stent placement of three metal biliary stents using a short double-balloon enteroscope", Endoscopy, 46(Suppl 1), pp.E417~E418 (2014)
- Saleem A, "Meta-analysis of randomized trials comparing the patency of covered and uncovered self-expandable metal stents for palliation of distal malignant bile duct obstruction", Gastrointest Endosc, 74, pp.321~327.e3 (2011)
- Kawakubo K, "Efficacy and safety of covered self-expandable metal stents for management of distal malignant biliary obstruction due to lymph node metastases", Surg Endosc, 25, pp.3094~3100 (2011)
- Fujii M, "Metallic stent insertion with double-balloon endoscopy for malignant afferent loop obstruction", World J Gastrointest Endosc, 7, pp.665~669 (2015)
- Sasaki T, "Double-balloon enteroscope-assisted enteral stent placement for malignant afferentloop obstruction after Roux-en-Y reconstruction", Endoscopy, 46(Suppl 1), pp.E541~E542 (2014)
- Shimatani M, "Through-the-scope self-expanding metal stent placement using newly developed short double-balloon endoscope for the effective management of malignant afferent-loop obstruction", Endoscopy, 48(Suppl 1), pp.E6~E7 (2016)