본문 바로가기
KERD
논문KCI 등재

A novel fully covered metal stent for unresectable malignant distal biliary obstruction: results of a multicenter prospective study

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Endoscopic self-expandable metal stent (SEMS) placement is currently the standard technique for treating unresectable malignant distal biliary obstructions (MDBO). Therefore, covered SEMS with longer stent patency and fewer migrations are required. This study aimed to assess the clinical performance of a novel, fully covered SEMS for unresectable MDBO. Methods: This was a multicenter single-arm prospective study. The primary outcome was a non-obstruction rate at 6 months. The secondary outcomes were overall survival (OS), recurrent biliary obstruction (RBO), time to RBO (TRBO), technical and clinical success, and adverse events. Results: A total of 73 patients were enrolled in this study. The non-obstruction rate at 6 months was 61%. The median OS and TRBO were 233 and 216 days, respectively. The technical and clinical success rates were 100% and 97%, respectively. Furthermore, the rate of occurrence of RBO and adverse events was 49% and 21%, respectively. The length of bile duct stenosis (<2.2 cm) was the only significant risk factor for stent migration. Conclusions: The non-obstruction rate of a novel fully covered SEMS for MDBO is comparable to that reported earlier but shorter than expected. Short bile duct stenosis is a significant risk factor for stent migration.

Abstract

Background/Aims: Endoscopic self-expandable metal stent (SEMS) placement is currently the standard technique for treating unresectable malignant distal biliary obstructions (MDBO). Therefore, covered SEMS with longer stent patency and fewer migrations are required. This study aimed to assess the clinical performance of a novel, fully covered SEMS for unresectable MDBO. Methods: This was a multicenter single-arm prospective study. The primary outcome was a non-obstruction rate at 6 months. The secondary outcomes were overall survival (OS), recurrent biliary obstruction (RBO), time to RBO (TRBO), technical and clinical success, and adverse events. Results: A total of 73 patients were enrolled in this study. The non-obstruction rate at 6 months was 61%. The median OS and TRBO were 233 and 216 days, respectively. The technical and clinical success rates were 100% and 97%, respectively. Furthermore, the rate of occurrence of RBO and adverse events was 49% and 21%, respectively. The length of bile duct stenosis (<2.2 cm) was the only significant risk factor for stent migration. Conclusions: The non-obstruction rate of a novel fully covered SEMS for MDBO is comparable to that reported earlier but shorter than expected. Short bile duct stenosis is a significant risk factor for stent migration.

참고문헌 (21)

  1. Nakai Y, "International consensus statements for endoscopic management of distal biliary stricture", J Gastroenterol Hepatol, 35, pp.967~979 (2020)
  2. Davids PH, "Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstruction", Lancet, 340, pp.1488~1492 (1992)
  3. Tringali A, "Covered vs. uncovered self-expandable metal stents for malignant distal biliary strictures : a systematic review and meta-analysis", Endoscopy, 50, pp.631~641 (2018)
  4. Isayama H, "A prospective randomised study of"covered"versus"uncovered"diamond stents for the management of distal malignant biliary obstruction", Gut, 53, pp.729~734 (2004)
  5. Kitano M, "Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma : a randomized multicenter trial", Am J Gastroenterol, 108, pp.1713~1722 (2013)
  6. Nakai Y, "Risk factors for covered metallic stent migration in patients with distal malignant biliary obstruction due to pancreatic cancer", J Gastroenterol Hepatol, 29, pp.1744~1749 (2014)
  7. Lawrence C, "A newly designed uncovered biliary stent for palliation of malignant obstruction : results of a prospective study", BMC Gastroenterol, 20, pp.184~ (2020)
  8. Isayama H, "TOKYO criteria 2014 for transpapillary biliary stenting", Dig Endosc, 27, pp.259~264 (2015)
  9. Kahaleh M, "Evaluation of a fully covered self-expanding metal stent with flared ends in malignant biliary obstruction : a multicenter study", J Clin Gastroenterol, 47, pp.e96~e100 (2013)
  10. Telford JJ, "A randomized trial comparing uncovered and partially covered self-expandable metal stents in the palliation of distal malignant biliary obstruction", Gastrointest Endosc, 72, pp.907~914 (2010)
  11. Lee JH, "Comparison of the utility of covered metal stents versus uncovered metal stents in the management of malignant biliary strictures in 749 patients", Gastrointest Endosc, 78, pp.312~324 (2013)
  12. Yang MJ, "Partially covered versus uncovered self-expandable nitinol stents with anti-migration properties for the palliation of malignant distal biliary obstruction : a randomized controlled trial", Scand J Gastroenterol, 50, pp.1490~1499 (2015)
  13. Krokidis M, "Percutaneous treatment of malignant jaundice due to extrahepatic cholangiocarcinoma : covered Viabil stent versus uncovered Wallstents", Cardiovasc Intervent Radiol, 33, pp.97~106 (2010)
  14. Krokidis M, "Percutaneous palliation of pancreatic head cancer : randomized comparison of ePTFE", FEP-covered versus uncovered nitinol biliary stents, 2011, pp.34, 352~361
  15. Knyrim K, "A prospective, randomized, controlled trial of metal stents for malignant obstruction of the common bile duct", Endoscopy, 25, pp.207~212 (1993)
  16. Prat F, "A randomized trial of endoscopic drainage methods for inoperable malignant strictures of the common bile duct", Gastrointest Endosc, 47, pp.1~7 (1998)
  17. Yamao K, "Utility and safety of a novel fully covered metal stent in unresectable distal malignant biliary obstruction", Dig Dis Sci, 65, pp.3702~3709 (2020)
  18. Marui S, "Utility of laser-cut covered self-expandable metal stents for unresectable malignant distal biliary obstruction : a single-center experience", Endoscopy, 52, pp.664~668 (2020)
  19. Kogure H, "A prospective multicenter study of a fully covered metal stent in patients with distal malignant biliary obstruction : WATCH-2 study", Dig Dis Sci, 63, pp.2466~2473 (2018)
  20. Park SB, "Metallic or plastic stent for bile duct obstruction in ampullary cancer?", Dig Dis Sci, 57, pp.786~790 (2012)
  21. Isayama H, "Measurement of radial and axial forces of biliary self-expandable metallic stents", Gastrointest Endosc, 70, pp.37~44 (2009)

관련 논문AI추천

Partially Covered Metal Stents May Not Prolong Stent Patency Compared to Uncovered Stents in Unresectable Malignant Distal Biliary Obstruction고규봉, 김선주, 김재윤, 문정호, 박상흠, 이윤나, 이태훈, 정윤호, 정일권, 조영신, 차상우, 최영덕, 최현종거트앤리버 소화기연관학회협의회 · Gut and Liver2017 · 제11권 제3호A Double-Layered Covered Biliary Metal Stent for the Management of Unresectable Malignant Biliary Obstruction: A Multicenter Feasibility Study정석, 동석호, 문종호, 박진석, 이규택, 이돈행거트앤리버 소화기연관학회협의회 · Gut and Liver2016 · 제10권 제6호A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet ObstructionHirofumi Kogure, Hiroshi Yagioka, Hiroyuki Isayama, Kazuhiko Koike, Minoru Tada, Naminatsu Takahara, Natsuyo Yamamoto, Osamu Togawa, Saburo Matsubara, Shuntaro Yoshida, Suguru Mizuno, Tomotaka Saito, Yousuke Nakai, Yukiko Ito거트앤리버 소화기연관학회협의회 · Gut and Liver2017 · 제11권 제4호Efficacy of multi-hole self-expandable metallic stents versus partially covered self-expandable metallic stents in patients with malignant distal biliary obstruction caused by unresectable pancreatic cancer: a retrospective comparative cohort study in JapanAkira Mitoro, Fumimasa Tomooka, Hitoshi Yoshiji, Jun-ichi Hanatani, Koh Kitagawa, Kosuke Kaji, Shohei Asada, Tomihiro Iwata, Yui Osaki, Yuki Motokawa대한소화기내시경학회 · Clinical Endoscopy2025 · 제58권 제5호Potential of 6-mm-diameter fully covered self-expandable metal stents for unresectable malignant distal biliary obstruction: a propensity score-matched studyAkihiro Ohba, Chigusa Morizane, Daiki Agarie, Daiki Yamashige, Hideki Ueno, Hidenobu Hara, Kohei Okamoto, Miyuki Sone, Shin Yagi, Shunsuke Kondo, Soma Fukuda, Susumu Hijioka, Takuji Okusaka, Tetsuro Takasaki, Yoshikuni Nagashio, Yutaka Saito, Yuta Maruki, Yuya Hagiwara대한소화기내시경학회 · Clinical Endoscopy2025 · 제58권 제1호A Novel, Fully Covered Laser-Cut Nitinol Stent with Antimigration Properties for Nonresectable Distal Malignant Biliary Obstruction: A Multicenter Feasibility StudyChimyon Gon, Hirofum Kogure, Hiroyuki Isayama, Kazuhiko Koike, Kazumichi Kawakubo, Keisuke Yamamoto, Kenji Hirano, Koji Miyabayashi, Kouta Inoue, Minoru Tada, Naoki Sasahira, Natsuyo Yamamoto, Rie Uchino, Saburo Matsubara, Suguru Mizuno, Takashi Sasaki, Takeshi Tsujino, Tsuyoshi Hamada, Yousuke Nakai, Yukiko Ito거트앤리버 소화기연관학회협의회 · Gut and Liver2013 · 제7권 제6호

이 간행물의 다른 논문 (18건)