Wearable medical device has been a resurgence of interest thanks to the development of technology andpropagation of smart phone in recent years. Various types of wearable devices have been introduced and availablein market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearabledevice. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrodeto body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram(ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system beadhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-todigitalconverter and wireless transmission module and designed to be attached on the body as a patch. To validatethe feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethaneand adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoringin real-life.
Abstract
Wearable medical device has been a resurgence of interest thanks to the development of technology andpropagation of smart phone in recent years. Various types of wearable devices have been introduced and availablein market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearabledevice. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrodeto body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram(ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system beadhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-todigitalconverter and wireless transmission module and designed to be attached on the body as a patch. To validatethe feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethaneand adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoringin real-life.
참고문헌 (20)
- H. S. Jeon, "Next generation of PC Wearable device market and technology trend", Weekly Technology Trend(www. nipa. kr), 1635, pp.14~26 (2014)
- A. Pantelopoulos., "A survey on wearable sensor-based systems for health monitoring and prognosis", Systems, Man, and Cybernetics, Part C : Applications and Reviews, IEEE Transactions on, 40, pp.1~12 (2010)
- H. H. Asada., "Mobile monitoring with wearable photoplethysmographic biosensors", Engineering in Medicine and Biology Magazine, IEEE, 22, pp.28~40 (2003)
- P. A. Shaltis., "Wearable, cuffless PPG-based blood pressure monitor with novel height sensor", Engineering in Medicine and Biology Society, 28th Annual International Conference of the IEEE, pp.908~911 (2006)
- M. Di Rienzo., "MagIC system : A new textile-based wearable device for biological signal monitoring. Applicability in daily life and clinical setting", Engineering in Medicine and Biology Society, 27th Annual International Conference of the IEEE, pp.7167~7169 (2005)
- J. S. Lee., "Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory Electrocardiogram", Sensors, 14, pp.14732~14743 (2014)
- L. B. Wood., "Noise cancellation model validation for reduced motion artifact wearable PPG sensors using MEMS accelerometers", Engineering in Medicine and Biology Society, 28th Annual International Conference of the IEEE, pp.3525~3528 (2006)
- M. Sung., "Shiver motion and core body temperature classification for wearable soldier health monitoring systems", Wearable Computers, Eighth International Symposium on, pp.192~193 (2004)
- L. F. Wang., "Polydimethyl- siloxane film for biomimetic dry adhesive integrated with capacitive biopotentials sensing", Sensors and Actuators B: Chemical (2014)
- T. Reinvuo., "Measurement of respiratory rate with high-resolution accelerometer and EMFit pressure sensor", Sensors Applications Symposium, Proceedings of the 2006 IEEE, pp.192~195 (2006)
- E. Sardini., "Instrumented wearable belt for wireless health monitoring", Procedia Engineering, 5, pp.580~583 (2010)
- D. Wu., "A wearable respiration monitoring system based on digital respiratory inductive plethysmography", Engineering in Medicine and Biology Society, Annual International Conference of the IEEE, pp.4844~4847 (2009)
- Y. G. Lim., "ECG measurement on a chair without conductive contact", Biomedical Engineering, IEEE Transactions on, 53, pp.956~959 (2006)
- H. J. Baek., "A smart health monitoring chair for nonintrusive measurement of biological signals", Information Technology in Biomedicine, IEEE Transactions on, 16, pp.150~158 (2012)
- T. Matsuda., "ECG monitoring of a car driver using capacitively-coupled electrodes", Engineering in Medicine and Biology Society, 30th Annual International Conference of the IEEE, pp.1315~1318 (2008)
- Y. G. Lim., "ECG recording on a bed during sleep without direct skin-contact", IEEE Transactions on Biomedical Engineering, 54(4), pp.718~725 (2007), Institute of Electrical and Electronics Engineers
- 이승민, "Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement", MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 48, pp.447~457 (2010), SPRINGER HEIDELBERG
- J. W. Jeong., "Capacitive Epidermal Electronics for Electrically Safe, Long-Term Electrophysiological Measurements", Advanced healthcare materials, 3, pp.642~648 (2014)
- 이원규, "침대 패드 형태의 용량성 전극에서 측정된 심전도 신호를처리하기 위한 자동 잡음 제거 및 피크 검출 알고리즘", 의공학회지, 35(4), pp.87~94 (2014), 대한의용생체공학회[DOI]
- 백현재, "Conductive Polymer Foam Surface Improves the Performance of a Capacitive EEG Electrode", IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 59, pp.3422~3431 (2012), IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC