To improve and downsize the KIOM-Pulse Analysis System(KIOM-PAS), which has been traditionally used in clinical trials, a miniaturized PAS(M-PAS) with a pneumatic pump has been developed. M-PAS is composed of a measurement module and an arm-mounting module, on which an arm can be placed. The measurement module is equipped with a pressing component and sensor, which is a wearable wristband. The arm-mounting module includes a pneumatic motor, data acquisition board and valves. In addition, the measurement module is divided into a fixing module of band type for attachment to a pulsation site and a sensing module, which includes a sensor and a tube. The fixing module and sensing module are constructed independently, and the detachable fastening method improves the posture convenience of the subject during measurement. M-PAS has been reduced to 1/6 the size of KIOM-PAS, and the measurement time is shortened by 22%. Using a simulator, the difference between the waveforms measured by the two devices exhibited a high degree of similarity of within 3.65%. M-PAS represents improvements in size and convenience compared with KIOM-PAS, and it is expected to be widely used in clinics in the future because it improves the attachment method of the fixing module.
Abstract
To improve and downsize the KIOM-Pulse Analysis System(KIOM-PAS), which has been traditionally used in clinical trials, a miniaturized PAS(M-PAS) with a pneumatic pump has been developed. M-PAS is composed of a measurement module and an arm-mounting module, on which an arm can be placed. The measurement module is equipped with a pressing component and sensor, which is a wearable wristband. The arm-mounting module includes a pneumatic motor, data acquisition board and valves. In addition, the measurement module is divided into a fixing module of band type for attachment to a pulsation site and a sensing module, which includes a sensor and a tube. The fixing module and sensing module are constructed independently, and the detachable fastening method improves the posture convenience of the subject during measurement. M-PAS has been reduced to 1/6 the size of KIOM-PAS, and the measurement time is shortened by 22%. Using a simulator, the difference between the waveforms measured by the two devices exhibited a high degree of similarity of within 3.65%. M-PAS represents improvements in size and convenience compared with KIOM-PAS, and it is expected to be widely used in clinics in the future because it improves the attachment method of the fixing module.
참고문헌 (13)
- K.C. KIM, "Pulse Biomedical Research Methodology", pp.37~40 (2008), DAEYOMEDI
- 유현희, "문헌을 통한 맥상의 물리적 요소 분석", 동의생리병리학회지, 21(6), pp.1381~1387 (2007), 한의병리학회
- 김현호, "Development of pulse diagnostic devices in Korea", Integrative Medicine Research, 2(1), pp.7~17 (2013), 한국한의학연구원[DOI]
- 이유정, "맥진기술동향 조사를 통한 맥진기 개발방안 제안", 동의생리병리학회지, 23(1), pp.174~179 (2009), 한의병리학회
- 이전, "촌, 관, 척 위치의 맥파 특징 차이 검정에 대한 1례", 한국한의학연구원논문집, 14(2), pp.107~112 (2008), 한국한의학연구원
- Y. Z. Yoon, "Contrivance of a Radial Pulse Measuring System with Variable Contact Pressure", J. Biomed. Eng. Res, 20(5), pp.567~572 (1999)
- J. U. Kim, "The Concept of Sasang Health Index and Constitution-Based Health Assessment : An Integrative Model with Computerized Four Diagnosis Methods", Evidence-Based Complementary and Alternative Medicine, 2013, pp.13~ (2013)
- 신재영, "Effects of Acupuncture Stimulation on the Radial artery’s Pressure Pulse Wave in Healthy Young Participants: Protocol for a prospective, single-Arm, Exploratory, Clinical Study", Journal of Pharmacopuncture, 19(3), pp.197~206 (2016), 대한약침학회[DOI]
- T. H. Kim, "Hemodynamic changes caused by acupuncture in healthy volunteers : a prospective, single-arm exploratory clinical study", BMC Complementary and Alternative Medicine, 17(1), pp.274~ (2017)
- 정창진, "토노메트리 방식 맥파 측정의 가입 각도에 따른 변동성 평가", 센서학회지, 25(2), pp.138~142 (2016), 한국센서학회
- Y.J. Jeon, "Linearity of pressure-response of a pulse diagnostic sensor composed of independently packaged 7 sensor modules", The Korean Institute of Electrical Engineers Bio Medical System Conference, pp.84~86 (2011)
- 배장한, "연속 가압방식의 맥파 측정방법을 위한시작점 검출 알고리즘 개발", 전자공학회논문지 - SC, 49(2), pp.46~54 (2012), 대한전자공학회
- L. Xu, "Morphology variability of radial pulse wave during exercise", Bio-Medical Materials and Engineering, 24, pp.3605~3611 (2014)