본문 바로가기
KERD
논문KCI 등재

사용 편의성과 소형화 기반의 맥파 측정장치 개발

Development of Pulse Analysis System Based on Convenience and Compactness

1

조회

0

다운로드

4

인용

0

참고문헌

키워드

초록

To improve and downsize the KIOM-Pulse Analysis System(KIOM-PAS), which has been traditionally used in clinical trials, a miniaturized PAS(M-PAS) with a pneumatic pump has been developed. M-PAS is composed of a measurement module and an arm-mounting module, on which an arm can be placed. The measurement module is equipped with a pressing component and sensor, which is a wearable wristband. The arm-mounting module includes a pneumatic motor, data acquisition board and valves. In addition, the measurement module is divided into a fixing module of band type for attachment to a pulsation site and a sensing module, which includes a sensor and a tube. The fixing module and sensing module are constructed independently, and the detachable fastening method improves the posture convenience of the subject during measurement. M-PAS has been reduced to 1/6 the size of KIOM-PAS, and the measurement time is shortened by 22%. Using a simulator, the difference between the waveforms measured by the two devices exhibited a high degree of similarity of within 3.65%. M-PAS represents improvements in size and convenience compared with KIOM-PAS, and it is expected to be widely used in clinics in the future because it improves the attachment method of the fixing module.

Abstract

To improve and downsize the KIOM-Pulse Analysis System(KIOM-PAS), which has been traditionally used in clinical trials, a miniaturized PAS(M-PAS) with a pneumatic pump has been developed. M-PAS is composed of a measurement module and an arm-mounting module, on which an arm can be placed. The measurement module is equipped with a pressing component and sensor, which is a wearable wristband. The arm-mounting module includes a pneumatic motor, data acquisition board and valves. In addition, the measurement module is divided into a fixing module of band type for attachment to a pulsation site and a sensing module, which includes a sensor and a tube. The fixing module and sensing module are constructed independently, and the detachable fastening method improves the posture convenience of the subject during measurement. M-PAS has been reduced to 1/6 the size of KIOM-PAS, and the measurement time is shortened by 22%. Using a simulator, the difference between the waveforms measured by the two devices exhibited a high degree of similarity of within 3.65%. M-PAS represents improvements in size and convenience compared with KIOM-PAS, and it is expected to be widely used in clinics in the future because it improves the attachment method of the fixing module.

참고문헌 (13)

  1. K.C. KIM, "Pulse Biomedical Research Methodology", pp.37~40 (2008), DAEYOMEDI
  2. 유현희, "문헌을 통한 맥상의 물리적 요소 분석", 동의생리병리학회지, 21(6), pp.1381~1387 (2007), 한의병리학회
  3. 김현호, "Development of pulse diagnostic devices in Korea", Integrative Medicine Research, 2(1), pp.7~17 (2013), 한국한의학연구원[DOI]
  4. 이유정, "맥진기술동향 조사를 통한 맥진기 개발방안 제안", 동의생리병리학회지, 23(1), pp.174~179 (2009), 한의병리학회
  5. 이전, "촌, 관, 척 위치의 맥파 특징 차이 검정에 대한 1례", 한국한의학연구원논문집, 14(2), pp.107~112 (2008), 한국한의학연구원
  6. Y. Z. Yoon, "Contrivance of a Radial Pulse Measuring System with Variable Contact Pressure", J. Biomed. Eng. Res, 20(5), pp.567~572 (1999)
  7. J. U. Kim, "The Concept of Sasang Health Index and Constitution-Based Health Assessment : An Integrative Model with Computerized Four Diagnosis Methods", Evidence-Based Complementary and Alternative Medicine, 2013, pp.13~ (2013)
  8. 신재영, "Effects of Acupuncture Stimulation on the Radial artery’s Pressure Pulse Wave in Healthy Young Participants: Protocol for a prospective, single-Arm, Exploratory, Clinical Study", Journal of Pharmacopuncture, 19(3), pp.197~206 (2016), 대한약침학회[DOI]
  9. T. H. Kim, "Hemodynamic changes caused by acupuncture in healthy volunteers : a prospective, single-arm exploratory clinical study", BMC Complementary and Alternative Medicine, 17(1), pp.274~ (2017)
  10. 정창진, "토노메트리 방식 맥파 측정의 가입 각도에 따른 변동성 평가", 센서학회지, 25(2), pp.138~142 (2016), 한국센서학회
  11. Y.J. Jeon, "Linearity of pressure-response of a pulse diagnostic sensor composed of independently packaged 7 sensor modules", The Korean Institute of Electrical Engineers Bio Medical System Conference, pp.84~86 (2011)
  12. 배장한, "연속 가압방식의 맥파 측정방법을 위한시작점 검출 알고리즘 개발", 전자공학회논문지 - SC, 49(2), pp.46~54 (2012), 대한전자공학회
  13. L. Xu, "Morphology variability of radial pulse wave during exercise", Bio-Medical Materials and Engineering, 24, pp.3605~3611 (2014)

관련 논문AI추천