호흡보조의료기기의 사용목적 및 대상에 따른 규격적용 방안 및 성능에 관한 연구
A Study for Application of Standard and Performance Test According to Purpose and Subject of Respiratory Medical Device
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The respiratory medical device is a medical device that delivers optimal oxygen or a certain amount of humidification to a patient by delivering artificial respiration to a patient through a machine when the patient has lost the ability to breathe spontaneously. These include respirators for use in chronic obstructive pulmonary disease and anesthesia or emergency situations, and positive airway pressure devices for treating sleep apnea, and as the population of COPD (chronic obstructive pulmonary disease) and elderly people worldwide surge, the market for the respiratory medical devices it is getting bigger. As the demand for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, the boundaries between the items are blurred due to the purpose, intended use, and method of use overlapping similar items in a respiratory medical device. In addition, for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, in this study, we propose clear classification criteria for the respiratory medical devices according to the purpose, intended use, and method of use and provide safety and performance evaluation guidelines for those items to help quality control of the medical devices. And to contribute to the rapid regulating and improvement of public health. This study investigated the safety and performance test methods through the principles of the respiratory medical device, national and international standards, domestic and international licensing status, and related literature surveys. The results of this study are derived from the safety and performance test items in the individual ventilator(ISO 80601-2-72), the International Standard for positive airway pressure device (ISO 80601-2-70), The safety and performance of humidifiers (ISO 80601-2-74) and the safety evaluation items related to home healthcare environment (IEC 60601-1-11), In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers and importers, certified test inspection institutions, academia, etc., the final guidelines were established through revision and supplementation. Therefore, in this study, we propose guidelines for evaluating the safety and performance of the respiratory medical device in accordance with growing technology development.
Abstract
The respiratory medical device is a medical device that delivers optimal oxygen or a certain amount of humidification to a patient by delivering artificial respiration to a patient through a machine when the patient has lost the ability to breathe spontaneously. These include respirators for use in chronic obstructive pulmonary disease and anesthesia or emergency situations, and positive airway pressure devices for treating sleep apnea, and as the population of COPD (chronic obstructive pulmonary disease) and elderly people worldwide surge, the market for the respiratory medical devices it is getting bigger. As the demand for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, the boundaries between the items are blurred due to the purpose, intended use, and method of use overlapping similar items in a respiratory medical device. In addition, for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, in this study, we propose clear classification criteria for the respiratory medical devices according to the purpose, intended use, and method of use and provide safety and performance evaluation guidelines for those items to help quality control of the medical devices. And to contribute to the rapid regulating and improvement of public health. This study investigated the safety and performance test methods through the principles of the respiratory medical device, national and international standards, domestic and international licensing status, and related literature surveys. The results of this study are derived from the safety and performance test items in the individual ventilator(ISO 80601-2-72), the International Standard for positive airway pressure device (ISO 80601-2-70), The safety and performance of humidifiers (ISO 80601-2-74) and the safety evaluation items related to home healthcare environment (IEC 60601-1-11), In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers and importers, certified test inspection institutions, academia, etc., the final guidelines were established through revision and supplementation. Therefore, in this study, we propose guidelines for evaluating the safety and performance of the respiratory medical device in accordance with growing technology development.
참고문헌 (15)
- Milliner BH, "A pilot study of improvised CPAP (iCPAP) via face mask for the treatment of adult respiratory distress in low-resource settings", International Journal of Emergency Medicine, 12(7) (2019)
- Shneerson JM, "Techniques in mechanical ventilation : principles and practice", Thorax, 51(7), pp.756~761 (1996)
- Kacmarek RM, "The Mechanical Ventilator. Past, Present, and Future", Respiratory Care, 56(8), pp.1170~1180 (2011)
- Venessa L. Pinto, "Continuous Positive Airway Pressure (CPAP)" (2019), StatPearls
- "ISO 80601-2-12:2011. Medical electrical equipment – Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators", ~ (2011)
- "ISO 80601-2-70:2015. Medical electrical equipment – Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipment", ~ (2015)
- "ISO 80601-2-72:2015. Medical electrical equipment – Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients", ~ (2015)
- "ISO 10651-6:2004. Lung ventilators for medical use – Particular requirements for basic safety and essential performance – Part 6: Home-care ventilatory support devices", ~ (2004)
- "ISO 80601-2-74:2017. Medical electrical equipment – Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipment", ~ (2017)
- "IEC 60601-1-11:2012. Medical electrical equipment – Part 1-11: General requirements for basic safety and essential performance - Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment", ~ (2012)
- "YY 0600.1-2007. Lung ventilators for medical use. Particular requirements for basic safety and essential performance. Part 1: Home-care ventilatory support devices", ~ (2007)
- "YY 0600.2-2007. Lung ventilators for medical use. Particular requirements for basic safety and essential performance. Part 2:Home care ventilators for ventilator-dependent patients", ~ (2007)
- "Standard 30. Ventilator", ~
- "Standard 30. General purpose Ventilator", ~