A Study of Electromagnetic Actuator for Electro-pneumatic Driven Ventricular Assist Device
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electro-pneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations.The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5 mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10 mm. The actuator dimension was 120 mm in diameter and 65 mm in height with a mass of 1.4 kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80 bpm when the afterload was 100mmHg.The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electro-pneumatic pump. The authors provide the above results as a preliminary data for further studies.
Abstract
An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electro-pneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations.The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5 mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10 mm. The actuator dimension was 120 mm in diameter and 65 mm in height with a mass of 1.4 kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80 bpm when the afterload was 100mmHg.The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electro-pneumatic pump. The authors provide the above results as a preliminary data for further studies.
참고문헌 (14)
- "Development of a totally implantable", 140, pp.17~25 (1980)
- "Research and development of an implantable axial-flow left ventricular assist device", 71, pp.125~132 (2001)
- "Effect of Pulsatility and hemodynamic power on recovery of renal function", 42, pp.720~723 (1996)
- "The role of Pulsatility in end-organ microcirculation after cardiogenic shock", 42, pp.724~729 (1996)
- "Progress on development of the Nimbus-University of Pittsburgh axial flow left ventricular assist system", 44, pp.521~524 (1998)
- "An implantable centrifugal blood pump for long term circulatory support", 43, pp.686~691 (1997)
- "In-vivo Evaluation of Pneumatic Ventricular Assist Device and Durability Improvement", 25(1), pp.65~70 (2004)
- "Progress in Artificial Organs-1985. Cleveland", iva(vich), pp.423~430 (1986), ISAO Press
- "Long-term studies with an electromechanical ventricular assist system in the calf and sheep Progress in Artificial Organs-1985. Cleveland", iva(vich), pp.456~463 (1986), ISAO Press
- "Roller screw electric motor ventricular assist device", 32, pp.46~48 (1986)
- "Chronic nonpulsatile blood flow II Hemodynamic responses to progressive exercise in calves with chronic nonpulsatile biventricular bypass", 111, pp.857~862 (1996)
- "Morphologic changes of the aortic wall due to reduced systemic pulse pressure in prolonged nonpulsatile left heart bypass", 43, pp.691~695 (1997)
- "AnyHeart: a single-piece heart-saving implantable artificial heart (BVAD)--monitoring and estimation", 26(5), pp.406~410 (2003)
- "Use of the AbioCor replacement heart as destination therapy for end-stage heart failure with irreversible pulmonary hypertension", 128(4), pp.643~645 (2004)