MRI용 심전도/혈류 게이팅 시스템 설계

Design of ECG/PPG Gating System in MRI Environment

0

조회

0

다운로드

0

인용

0

참고문헌

초록

Abstract

MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

참고문헌 (9)

  1. M.K. Laudon, "Minimizing interference from magnetic resonance imagers during electrocar- diography", 45(2), pp.160~164 (1998)
  2. J. Felblinger, "Electrocardiogram acqui- sition during MR examinations for patient monitoring and sequence trigering Magnetic Resonance In Medicine", 32, pp.523~529 (1994)
  3. R. Rokey, "Monitoring of acutely il patients during nuclear magnetic resonance imaging Using of a time-varing filter electrocardiographic gating device to reduce gradient artifacts Magnetic Resonance In Medicine", 6, pp.240~245 (1988)
  4. A.N. Shety, "Supresion of radiofrequency interference in cardiac gated MRI Magnetic Resonance In Medicine", 8, pp.84~88 (1988)
  5. R.E. Wendt 3rd, "Electrocardiographic gating and monitoring in NMR imaging", 6, pp.89~95 (1988)
  6. S. Jones, "Burns asociated with electrocar- diographic monitoring during magnetic resonance imaging", 22(5), pp.420~421 (1996)
  7. S.J. Kens, "Burns caused by ECG monitoring during MRI imaging", 51(12), pp.18~189 (1996)
  8. R.N. Dimick, "Optimizing electrocardiograph electrode placement for cardiacgated magnetic resonance imaging", 22, pp.17~22 (1987)
  9. R. Abacherli, "Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates", 18(1), pp.41~50 (2005)

관련 논문AI추천

이 간행물의 다른 논문 (20건)