본문 바로가기
KERD
논문KCI 등재

가속도계를 이용한 광전용적맥파의 동잡음 제거

A study on accelerometer based motion artifact reduction in Photoplethysmography signal

1

조회

0

다운로드

6

인용

0

참고문헌

초록

Abstract

With the convergence of ubiquitous networking and medical technologies, ubiquitous healthcare(U-Healthcare) service has come in our life, which enables a patient to receive medical services at anytime and anywhere. In the u-Healthcare environment, intelligent real-time biosignal aquisition/analysis techniques are inevitable. In this study, we propose a motion artifact cancelation method in portable photoplethysmography(PPG) signal aquisition using an accelerometer and an adaptive filter. A preliminary experiment represented that the component of the pedestrian motion artifact can be found under 5Hz in the spectral analysis. Therefore, we collected PPG signals under both simulated conditions with a motor that generates circular motion with uniform velocity (from 1 to 5Hz) and a real walking condition. We then reduced the motion artifact using a recursive least square adaptive filter which takes the accelerometer output as a noise reference. The results showed that the adaptive filter can remove the motion artifact effectively and recover peak points in PPG signals, which represents our method can be useful to detect heart rate in real walking condition.

참고문헌 (13)

  1. Mark Weiser, "The computer for the twenty- first century", 265, pp.94~ (1991)
  2. M. Coen, "The future of human-computer interaction or how I learned to stop worrying and love my Intelligent Room", 14(2), pp.8~10 (1999)
  3. Kim Woo-Shik, "A study on the seamless monitoring over the wireless LAN and the public cellular network for a portable patient monitoring system", 22(1), pp.14~21 (2006)
  4. K.K. Tremper, "Pulse Oximetry and Oxygen Transform. Pulse Oximetry" (1986), Springer-Verlag
  5. M.J. Hayes, "Artifact reduction in photoplethysmograthy", 37(31), pp.7437~7446 (1998)
  6. J.G. Webster, "Design of Pulse Oximeters Institute of Physics Publishing", pp.124~158 (1997)
  7. G.H. Kim, "Extraction of Artifacts and SpO2 Sources of Measured Signal from Pulse Oximeter using Independent Component Analysis" (2004)
  8. M.R. Neuman, "Motion artifact in pulse oximetry", 12
  9. T.L. Rusch, "Signal processing methods for pulse oximetry", 26(2), pp.143~159 (1996)
  10. B.S. Kim, "Motion artifact reduction in photoplethysmography using independent component analysis", 53(3), pp.566~568 (2006)
  11. C.M. Lee, "Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach", pp.194~195 (2003)
  12. K.W Chan, "Adaptive reduction of motion artifact from photoplethysmographic recordings using a variable step-size LMS filter", 2, pp.1343~1346 (2002)
  13. Simon Haykin, "Adaptive Filter Theory" (1996), Prentice-Hall

관련 논문AI추천

이 간행물의 다른 논문 (16건)