Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.

Abstract

Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.

참고문헌 (24)

  1. P.J. Littrup, "Determination of prostate volume with transrectal US for cancer screening.Part I.Comparion with prostate-specific antigen assays", Radiologyvol, 178(2), pp.537~542 (1991)
  2. W.H. Cooner, "Clinical application of transrectal ultrasonography and prostate-specific antigen in the search for prostate cancer", J.Urology, 139(4), pp.758~761 (1998)
  3. J.T. Isaac, "Etiology and disease process of benign prostatic hyperplasia", Prostate, 2, pp.33~50 (1989)
  4. S.J. Berry, "The development of human benign prostate hyperplasia with age", J.Urology, 132(3), pp.474~479 (1984)
  5. J. Freedland, "Prostate specific antigen recurrence after definitive therapy", J.Urology, 177(6), pp.1985~1991 (2007)
  6. C.G.. Roehrborn, "Correlation between prostate size estimated by digital rectal examination and measured by transrectal ultrasound", Urology, 49(4), pp.548~557 (1997)
  7. C.M. Sehgal, "Three-dimensional US and volumetric assessment of the prostate", Radiology, 192, pp.274~278 (1994)
  8. J.H. Byun, "Endorectal MRI of Prostate Cancer:Comparison with Findings on Radical Prostatectomy", Korea J.Radiology, 40(5), pp.947~951 (1999)
  9. M. al-Rimawi, "Transrectal ultrasound versus magnetic resonance imaging in the estimation of prostatic volume", Br.J.Urology, 74(5), pp.596~600 (1994)
  10. J. Sosna, "Determination of prostate volume at 3-Tesla using an external phased array coil:comparison to pathologic specimens", Acad.Radiol, 10(8), pp.846~853 (2003)
  11. H. Hu, "Four multidetector-row helical CT:image quality and volume coverage speed", Radiology, 215(1), pp.55~62 (2000)
  12. C. Kayaalp, "Liver volume measurement by spiral CT:an in vitro study", Clin.Imaging, 26(2), pp.122~124 (2002)
  13. M.M. Rehani, "Radiation doses in computed tomography", Br.Med.J, 320, pp.593~594 (2000)
  14. J.O. Salo, "Computerized tomography and transrectal ultrasound in the assessment of local extension of prostatic carcinoma before radical retropublic prostatectomy", J.Urology, 137, pp.435~438 (1987)
  15. C.H. Bangma, "Transrectal ultrasonic volumetry of the prostate:in vivo comparision of different methods", Prostate, 28(2), pp.107~110 (1996)
  16. W.F.Dähnet, "Determination of prostate volume with transrectal US for cancer screening", Radiology, 183, pp.625~626 (1992)
  17. H.C. Kim, "Usefulness of renal volume measurements obtained by a 3-dimentional sonographic transducer with matrix electronic arrays", AIUM.J.Ultrasound, 27, pp.1673~1681 (2008)
  18. E.C.Kwon, "Introduction of 3D Ultrasound System and Clinical Usefulness of 3D Ultrasound Image", J.KIISE, 23(10), pp.38~48 (2005)
  19. Sun Ho Kim, "Correlations between the Various Methods of Estimating Prostate Volume: Transabdominal, Transrectal, and Three-Dimensional US", Korean Journal of Radiology, 9(2), pp.134~139 (2008), 대한영상의학회
  20. 조정연, "곤약 모델을 이용한 경직장 초음파상 전립선 부피측정법의 비교", 대한초음파의학회지, 21(1), pp.23~29 (2002), 대한초음파의학회
  21. M.K. Terris, "Determination of prostate volume by transrectal ultrasound", J.Urology, 145(5), pp.984~987 (1991)
  22. C.A. Mochtar, "Prostate-specific antigen as an estimator of prostate volume in the management of patients with symptomatic benign prostatic hyperplasia", Eur.Urology, 44(6), pp.695~700 (2003)
  23. C.G. Roehrborn, "Serum prostate-specific antigen as a predictor of prostate volume in men with benign prostatic hyperplasia", Urology, 53(3), pp.581~589 (1999)
  24. 정창욱, "경직장초음파와 자기공명영상 전립선용적과 근치적 전립선적출술 후 실제 전립선용적 비교 연구", Korean Journal of Urology, 46(6), pp.579~585 (2005), 대한비뇨기과학회

관련 논문AI추천