본문 바로가기
KERD
논문KCI 등재

LMS 적응필터를 이용한 직교 함수 기반의 CPR 잡음 제거 알고리즘 설계

Design of CPR Artifact Removal Algorithm Based on Orthogonal Function using LMS Adaptive Filter

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

This study proposes an algorithm for removal of CPR artifact in order that automated external defibrillator (AED) can effectively diagnose ECG rhythm during cardiopulmonary resuscitation (CPR). Current AED required to interrupt chest compression for reliable rhythm analysis to avoid the effect of artifacts produced by CPR. However even temporarily interruption of chest compression during CPR adversely affects the probability of restoration of spontaneous circulation (ROSC) and survival after the delivery of the shock. Therefore, we proposed a method for removal of CPR artifacts using least mean square (LMS) filter. The removal of the CPR artifacts would enable compressions to continue during AED rhythm analysis, thereby increasing the likelihood of resuscitation success. It was tested on 31 segments of shockable and 300 segments of non-shockable ECG signals recorded from three pigs during CPR. In the result, sensitivity (Se) and specificity (Sp) analysis on the test segments showed values of Se = 3.2%, Sp = 66.0% and Se = 96.8%, Sp = 98.7% in the case of unfiltered and filtered signals during CPR. In conclusion, it was shown that the proposed method can be a useful tool to exactly diagnose the ECG rhythm during the CPR.

Abstract

This study proposes an algorithm for removal of CPR artifact in order that automated external defibrillator (AED) can effectively diagnose ECG rhythm during cardiopulmonary resuscitation (CPR). Current AED required to interrupt chest compression for reliable rhythm analysis to avoid the effect of artifacts produced by CPR. However even temporarily interruption of chest compression during CPR adversely affects the probability of restoration of spontaneous circulation (ROSC) and survival after the delivery of the shock. Therefore, we proposed a method for removal of CPR artifacts using least mean square (LMS) filter. The removal of the CPR artifacts would enable compressions to continue during AED rhythm analysis, thereby increasing the likelihood of resuscitation success. It was tested on 31 segments of shockable and 300 segments of non-shockable ECG signals recorded from three pigs during CPR. In the result, sensitivity (Se) and specificity (Sp) analysis on the test segments showed values of Se = 3.2%, Sp = 66.0% and Se = 96.8%, Sp = 98.7% in the case of unfiltered and filtered signals during CPR. In conclusion, it was shown that the proposed method can be a useful tool to exactly diagnose the ECG rhythm during the CPR.

참고문헌 (14)

  1. Go AS, "Heart Disease and Stroke Statistics-2013 Update" (2013), American Heart Association
  2. Herlitz J, "Rhythm changes during resuscitation from ventricular fibrillation in relation to delay until defibrillation, number of shocks delivered and survival", Resuscitation, 34(1), pp.17~22 (1997)
  3. Snyder D, "Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy", Critical care medicine, 32(9), pp.421~424 (2004)
  4. Rhythm analysis during cardiopulmonary resuscitation : past, present, and future, "Ruiz DG", BioMed research international, ~ (2014)
  5. Li Y, "Identifying potentially shockable rhythms without interrupting cardiopulmonary resuscitation", Critical Care Medicine, 36(1), pp.198~203 (2008)
  6. EilevstjØnn J, "Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG", Resuscitation, 61(2), pp.131~141 (2004)
  7. Rheinberger K, "Removal of CPR artifacts from the ventricular fibrillation ECG by adaptive regression on lagged reference signals", IEEE Transactions on Biomedical Engineering, 55(1), pp.130~137 (2008)
  8. Werther T, "CPR artifact removal in ventricular fibrillation ECG signals using gabor multipliers", IEEE Transactions on Biomedical Engineering, 56(2), pp.320~327 (2009)
  9. Ruiz DG, "A method to remove CPR artefacts from human ECG using only the recorded ECG", Resuscitation, 76(2), pp.271~278 (2008)
  10. Aramendi E, "Suppression of the cardiopulmonary resuscitation artefacts using the instantaneous chest compression rate extracted from the thoracic impedance", Resuscitation, 83(6), pp.692~698 (2012)
  11. Nam DH, "Detection Method for Shockable Rhythm Based on a Single Feature", Electronics Letters, 52(9), pp.686~688 (2016)
  12. Kuo S, "Computer detection of ventricular fibrillation", Computers in Cardiology, pp.2747~2750 (1978)
  13. Goldberger A L, "Physiobank, physiotoolkit, and physionet components of a new research resource for complex physiologic signals", Circulation, 101(23), pp.215~220 (2000)
  14. Grundler WG, "Observations on colloid osmotic pressure, hematocrit, and plasma osmolality during cardiac arrest", Critical Care Medicine, 13(11), pp.895~896 (1985)

관련 논문AI추천

이 간행물의 다른 논문 (5건)