본문 바로가기
KERD
논문KCI 등재

손 동작 스캔을 이용한 잔뇨량 측정용 초음파 방광 스캐너

A New Ultrasound Bladder Scanner to Estimate Urine Volume Using Hand-Motion Scan

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

3D ultrasound bladder scanners are getting popular in hospitals for the patients with bladder dysfunction. A current bladder scanner adopts a mechanical scan to acquire 3D images and requires two motors and complicated mechanical devices. In this paper, we propose a new ultrasound bladder scanner using hand-motion scan. Instead of two motors and mechanical devices, it has a motion sensor to record transducer positions during hand-motion scan. The experiments with a bladder phantom and volunteers showed similar measurement accuracy to a conventional 3D ultrasound bladder scanner. We expect that the proposed method will reduce the cost and size of the bladder scanner.

Abstract

3D ultrasound bladder scanners are getting popular in hospitals for the patients with bladder dysfunction. A current bladder scanner adopts a mechanical scan to acquire 3D images and requires two motors and complicated mechanical devices. In this paper, we propose a new ultrasound bladder scanner using hand-motion scan. Instead of two motors and mechanical devices, it has a motion sensor to record transducer positions during hand-motion scan. The experiments with a bladder phantom and volunteers showed similar measurement accuracy to a conventional 3D ultrasound bladder scanner. We expect that the proposed method will reduce the cost and size of the bladder scanner.

참고문헌 (12)

  1. J.H. Holmes, "Ultrasonic studies of bladder", J. Urol., 97(4), pp.654~663 (1967)[DOI]
  2. J.M. Walton, "Comparison of real-time ultrasonography and magnetic resonance imaging in the assessment of urinary bladder volume", Br. J. Urol., 78(6), pp.856~861 (1996)[DOI]
  3. K.A. Ung, "Comparison study of portable bladder scanner versus conebeam CT scan for measuring bladder volumes in post-prostatectomy patients undergoing radiotherapy", J. Med. Imaging. Radiat. Oncol., 58(3), pp.377~383 (2014)[DOI]
  4. J.F. Pedersen, "Residual urine determination by ultrasonic scanning", Am. J. Roentgenol. Radium. Ther. Nucl. Med., 125(2), pp.474~478 (1975)[DOI]
  5. J. Kjeldsen-Kragh, "Measurement of Residual Urine Volume by Means of Ultrasonic Scanning : A Comparative Study", Paraplegia, 26(3), pp.192~199 (1988)
  6. G.J. Poston, "The accuracy of ultrasound in the measurement of changes in bladder volume", Br. J. Urol., 55(4), pp.361~363 (1986)
  7. E.A. Kiely, "Measurement of bladder volume by real-time ultrasound", Br. J. Urol., 60(1), pp.33~35 (1987)[DOI]
  8. V. Chalana, "Image enhancement and segmentation of fluid-filled structures in 3D ultrasound images", Proc. of SPIE, 5032, pp.500~506 (2003)
  9. W.T. Higgins, "A comparison of complementary and Kalman filtering", IEEE Trans. Aerosp. Electron. Syst., AES-11(3), pp.321~325 (1975)[DOI]
  10. B.B. Graham, "Using an Accelerometer Sensor to Measure Human Hand Motion", pp.2000
  11. 조태식, "3D 초음파 영상에서 방광 내 잔뇨량 추정을 위한 새로운 알고리즘", 의공학회지, 37(1), pp.31~38 (2016), 대한의용생체공학회
  12. D.J. Schuirmann, "A comparison of the Two One-Sided Tests Procedure and the Power Approach for assessing the equivalence of average bioavailability", J. Pharmacokinet. Biopharm., 15(6), pp.657~680 (1987)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (3건)