수압 측정에 기반하는 요류검사의 정확도 검증
Accuracy validation of urinary flowmetry techniquebased on pressure measurement
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Uroflowmetry is a non-invasive clinical test useful for screening benign prostatic hyperplasia(BPH) common in the aged men. The current standard way to obtain the urinary flow rate is to continuously acquire the urine weight signal proportional to volume over time. The present study proposed an alternative technique measuring pressure to overcome noise problems present in the standard weight measuring technique. Experiments were performed to simultaneously acquire both weight and pressure changes during urination of 9 normal men. Noise components were separated from volume signals converted from both weight and pressure signals based on the polynomial signal model. Signal-to-noise ratio was defined as the ratio of the energies between signal and noise components of the measured volume changes, which was 8.5 times larger in the pressure measuring technique, implying that cleaner signal could be obtained, more immune to noisy environments. When four important diagnostic parameters were estimated, excellent correlation coefficients higher than 0.99 were resulted with mean relative errors less than 5%. Therefore, the present pressure measurement seemed valid as an alternative technique for uroflowmetry.
Abstract
Uroflowmetry is a non-invasive clinical test useful for screening benign prostatic hyperplasia(BPH) common in the aged men. The current standard way to obtain the urinary flow rate is to continuously acquire the urine weight signal proportional to volume over time. The present study proposed an alternative technique measuring pressure to overcome noise problems present in the standard weight measuring technique. Experiments were performed to simultaneously acquire both weight and pressure changes during urination of 9 normal men. Noise components were separated from volume signals converted from both weight and pressure signals based on the polynomial signal model. Signal-to-noise ratio was defined as the ratio of the energies between signal and noise components of the measured volume changes, which was 8.5 times larger in the pressure measuring technique, implying that cleaner signal could be obtained, more immune to noisy environments. When four important diagnostic parameters were estimated, excellent correlation coefficients higher than 0.99 were resulted with mean relative errors less than 5%. Therefore, the present pressure measurement seemed valid as an alternative technique for uroflowmetry.
참고문헌 (7)
- B. Lukacs, "One-year follow-up of 2829 patients with moderate to severe lower urinary tract symptoms treated with alfuzosin in general practice according to IPSS and a health-related quality-of-life questionnaire", BPM Group in General Practice. Urology, 55(4), pp.540~546 (2000)
- M. W. Kim, "Highly recommended test and important test, In: Textbook of benign prostatic hyperplasia", pp.127~146 (2004), Ilchokak Press
- A. Talalla, "Encyclopedia of medical devices and instrumentatin" (1988), A Wiley-Interscience Publication
- 김경아, "압력 측정에 의한 요량 계측의 유용성 분석", 의공학회지, 28(4), pp.577~584 (2007), 대한의용생체공학회
- A. B. Carlson, "Communication systems", pp.75~77 (1975), McGraw-Hill
- A. B. Carlson, "Communication systems", pp.148~150 (1975), McGraw-Hill
- G. D. Webster, "Campbell’s urology" (2002), Saunders