본문 바로가기
KERD
논문KCI 등재

척추의 해부학적 요소를 고려한 척추경 나사못 디자인의 Pullout 특성 연구

A Study on Pullout Characteristics of Pedicle Screw Design Considering Anatomical Structure of the Lumbar Spine

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Recently, various types of pedicle screws have been developed considering the anatomical structure of the spine. The purpose of this study was to evaluate the pullout stiffness and strength of two types of commercial pedicle screws. The design of two type screws were single pitched thread (ST) pedicle screw and dual pitched thread (DT) pedicle screw, respectively. The tests were conducted in accordance with the ASTM standards using polyurethane (PU) test blocks which has anatomical structure of the spine. There was no significant difference in pullout stiffness between two types of screw. However, DT exhibited higher pullout strength than ST (p<0.05). Pedicle screw with dual pitched thread showed higher pullout strength without decrease in pullout stiffness compared to the standard pedicle screw. In conclusion, dual pitched thread design of the pedicle screw is considered to be more suitable than the single pitched thread for the anatomical structure of the spine.

Abstract

Recently, various types of pedicle screws have been developed considering the anatomical structure of the spine. The purpose of this study was to evaluate the pullout stiffness and strength of two types of commercial pedicle screws. The design of two type screws were single pitched thread (ST) pedicle screw and dual pitched thread (DT) pedicle screw, respectively. The tests were conducted in accordance with the ASTM standards using polyurethane (PU) test blocks which has anatomical structure of the spine. There was no significant difference in pullout stiffness between two types of screw. However, DT exhibited higher pullout strength than ST (p<0.05). Pedicle screw with dual pitched thread showed higher pullout strength without decrease in pullout stiffness compared to the standard pedicle screw. In conclusion, dual pitched thread design of the pedicle screw is considered to be more suitable than the single pitched thread for the anatomical structure of the spine.

참고문헌 (25)

  1. Boucher HH, "A method of spinal fusion", J Bone Joint Surg Br, 41, pp.248~259 (1959)
  2. Cotrel Y, "New universal instrumentation in spinal surgery", Clin Orthop Relat Res, 227, pp.10~23 (1988)
  3. Inceoglu S, "Axial cyclic behavior of the bone–screw interface", Med Eng Phys, 28(9), pp.888~893 (2006)
  4. McAfee PC, "Survivorship analysis of pedicle spinal instrumentation", Spine, 16(8), pp.422~427 (1991)
  5. Lonstein JE, "Complications associated with pedicle screws", J Bone Joint Surg Am, 81(11), pp.1519~1528 (1999)
  6. DeWald CJ, "Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65. Surgical considerations and treatment options in patients with poor bone quality", Spine, 31(19), pp.144~151 (2006)
  7. Ponnusamy KE, "Instrumentation of the osteoporotic spine : biomechanical and clinical considerations", Spine J, 11(1), pp.54~63 (2011)
  8. Giacaglia GEO, "Pedicle screw rupture : A case study", Case Studies in Engineering Failure Analysis, 4, pp.64~75 (2015)
  9. Cook SD, "Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design", J Spinal Disord, 13(3), pp.230~236 (2000)
  10. Lei W, "Biomechanical evaluation of an expansive pedicle screw in calf vertebrae", Eur Spine J, 15(3), pp.321~326 (2005)
  11. Becker S, "Assessment of different screw augmentation techniques and screw designs in osteoporotic spines", Eur Spine J, 17(11), pp.1462~1469 (2008)
  12. Kim YY, "Assessment of pedicle screw pullout strength based on various screw designs and bone densities—an ex vivo biomechanical study", Spine J, 12(2), pp.164~168 (2012)
  13. Yaman O, "The comparison of pullout strengths of various pedicle screw designs on synthetic foams and ovine vertebrae", Turk Neurosurg, 25(4), pp.532~538 (2015)
  14. 최선각, "척추경 나사못의 디자인이 고정력 및 구동 토크에 미치는영향 분석: 이중 나사 및 이중 피치 나사", 의공학회지, 39(3), pp.134~139 (2018), 대한의용생체공학회
  15. ASTM Standards, "F1839-08(2016), Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopaedic Devices and Instruments", ~ (2016)
  16. ASTM Standards, "F543-17, Standard Specification and Test Methods for Metallic Medical Bone Screws", ~ (2017)
  17. Abshire BB, "Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out", Spine J., 1(6), pp.408~414 (2001)
  18. Ono A, "Triangulated pedicle screw construct technique and pull-out strength of conical and cylindrical screws", J Spinal Disord, 14(3), pp.323~329 (2001)
  19. Kwok AW, "Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone", Spine, 21(21), pp.2429~2434 (1996)
  20. Brasiliense LB, "Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spines", Spine J, 13(8), pp.947~956 (2013)
  21. Sevastik B, "Vertebral rotation and pedicle length asymmetry in the normal adult spine", Eur Spine J, 4(2), pp.95~97 (1995)
  22. Krenn MH, "Influence of thread design on pedicle screw fixation", J Neurosurg Spine, 9, pp.90~95 (2008)
  23. Chen CS, "Failure analysis of broken pedicle screws on spinal instrumentation", Med Eng Phys, 27(6), pp.487~496 (2005)
  24. Inceoglu S, "Cortex of the pedicle of the vertebral arch. Part I: Deformation characteristics during screw insertion", J Neurosurg Spine, 7(3), pp.341~346 (2007)
  25. Vafadar S, "The effects of geometrical parameters of the pedicle screw on its pullout strength : In-vitro animal tests", J Orthop Spine Trauma, 3(4), pp.e74189~ (2007)

관련 논문AI추천

이 간행물의 다른 논문 (3건)