2D 영상마커 추적 기반 시린지펌프 투약속도 실시간 감시 기술 개발
Real-time Monitoring of the Actual Infusion Rate of Syringe Pump Using 2D Image Marker Tracking
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose: To propose a new infusion rate monitoring technique based on the 2D image marker tacking to improve patient safety by preventing syringe pump-related medication accidents due to decreased infusion rate control accuracy. Materials and Methods: The infusion rate of the syringe pump and drug residue in the pump-equipped syringe were monitored in real time by tracking the movement of the 2D image markers attached to the syringe pump. Results: The error rate between the set and the estimated infusion rates was 1.03, 0.66, 1.95, 0.23, and 1.05% when the infusion rate setting was 10, 20, 30, 40, and 50 mL/H, respectively. In addition, the error rate between the actual and the estimated drug residues was 1.04, 0.47, 0.60, 3.66, and 0.00% when the infusion rate setting was 10, 20, 30, 40, and 50 mL/H, respectively. Conclusion: Experimental results demonstrated that the proposed technique can increase the efficiency of the safety management system for seriously ill inpatients by decreasing a possibility of syringe pump- related medication accidents in hospitals.
Abstract
Purpose: To propose a new infusion rate monitoring technique based on the 2D image marker tacking to improve patient safety by preventing syringe pump-related medication accidents due to decreased infusion rate control accuracy. Materials and Methods: The infusion rate of the syringe pump and drug residue in the pump-equipped syringe were monitored in real time by tracking the movement of the 2D image markers attached to the syringe pump. Results: The error rate between the set and the estimated infusion rates was 1.03, 0.66, 1.95, 0.23, and 1.05% when the infusion rate setting was 10, 20, 30, 40, and 50 mL/H, respectively. In addition, the error rate between the actual and the estimated drug residues was 1.04, 0.47, 0.60, 3.66, and 0.00% when the infusion rate setting was 10, 20, 30, 40, and 50 mL/H, respectively. Conclusion: Experimental results demonstrated that the proposed technique can increase the efficiency of the safety management system for seriously ill inpatients by decreasing a possibility of syringe pump- related medication accidents in hospitals.
참고문헌 (16)
- Brocx S, "When and how to use a syringe driver in palliative care", Best Practice J, 48, pp.28~35 (2012)
- Kim GH, "A new injection rate estimation technique for on-site screening test of medication infusion pump by nurses", P I Mech Eng H, 234(4), pp.370~376 (2020)
- Batliner M, "Evaluation of a novel flow-controlled infusion pump for precise and continuous drug delivery at low flow rates : a laboratory study", Anaesthesia, 74(11), pp.1425~1431 (2019)
- "Health insurance treatment statistics for inpatients in intensive care units" (2022)[URL]
- Lin L, "Patient safety, potential adverse drug events, and medical device design : a human factors engineering approach", J Biomed Inform, 34(4), pp.274~284 (2001)
- Vicente KJ, "Programming errors contribute to death from patient-controlled analgesia : case report and estimate of probability", Can J Anaesth, 50(4), pp.328~332 (2003)
- Syed S, "Morphine overdose from error propagation on an acute pain service", Can J Anaesth, 53(6), pp.586~590 (2006)
- 박호준, "위험관리기반의 성능관리 의료기기 선정 절차 수립 및 시험 항목 도출", 의공학회지, 40(1), pp.20~31 (2019), 대한의용생체공학회
- International Electrotechnical Commission, "IEC 60601-2-24:Medical electrical equipment-Part 2-24: Particular requirements for the basic safety and essential performance of infusion pumps and controllers", 17~34 (2012)
- Batliner M, "Evaluation of a novel flow-controlled syringe infusion pump for precise and continuous drug delivery at low flow rates : a laboratory study", Anaesthesia, 74(11), pp.1425~1431 (2019)
- AnJani AG, "Application of IoT using nodeMCU ESP8266 on the Syringe Pump Device to Increase Patient Safety", Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics, 4(1), pp.23~27 (2022)
- Das S, "A Pencil Drawn Capacitive Sensor used for Liquid Drug Volume Measurement in Syringe Pump", 2020IEEE Applied Signal Processing Conference (ASPCON), pp.85~88 (2020)
- Hagihghi R, "A miniaturized piezoresistive flow sensor for real-time monitoring of intravenous infusion", Journal of Biomedical Materials Research Part B : Applied Biomaterials, 108(2), pp.568~576 (2020)
- Shen Z, "Biomimetic flow sensors for biomedical flow sensing in intravenous tubes", 2016 IEEE SENSORS, 1~3 (2016)
- Islam MR, "Design and Implementation of Low Cost Smart Syringe Pump for Telemedicine and Healthcare", 2019 International Conference on Robotics, Electrical and Signal Processing Techniques (ICREST), pp.440~444 (2019)
- Rajasekwaran S, "Iot based low cost syringe pump for telemedicine and health care", International Research Journal of Modernization in Engineering Technology and Science, 4(6), pp.4222~4229 (2022)