Comparative analysis of complex factors affecting the accuracy of injection volume of remote fluid monitoring system
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Recently, the prevalence of remotely managed patient care systems in medical institutions is increasing due to COVID-19. In particular, in the case of fluid monitoring, hospitals are considering introducing it as a system that can reduce patient safety and nurses' work. There are two products under development: a load cell method that measures weight and a method that detects drops of sap by infrared sensing. Although each product has differences in operation principle, sensor type, size, usage, and price, medical institutions are highly interested in the accuracy of the data obtained.In this study, two prototypes with different sensor methods were manufactured and the total amount of infusion per hour was measured to test the accuracy, which is the core of the infusion monitoring device. In addition, when there was an external movement, the change in the measured value of the sap was tested to evaluate the accuracy according to the measurement method. As a result of the experiment, there was a difference of less than 5% in the measurement value error of the two devices, and the load cell method showed a difference in the low-capacity measurement value and the infrared method in the high-capacity measurement value. As a result of this experiment, there was little difference in accuracy according to the sensor method of the infusion monitoring device, and it is considered that there is no problem in accuracy when used in a medical institution.
Abstract
Recently, the prevalence of remotely managed patient care systems in medical institutions is increasing due to COVID-19. In particular, in the case of fluid monitoring, hospitals are considering introducing it as a system that can reduce patient safety and nurses' work. There are two products under development: a load cell method that measures weight and a method that detects drops of sap by infrared sensing. Although each product has differences in operation principle, sensor type, size, usage, and price, medical institutions are highly interested in the accuracy of the data obtained.In this study, two prototypes with different sensor methods were manufactured and the total amount of infusion per hour was measured to test the accuracy, which is the core of the infusion monitoring device. In addition, when there was an external movement, the change in the measured value of the sap was tested to evaluate the accuracy according to the measurement method. As a result of the experiment, there was a difference of less than 5% in the measurement value error of the two devices, and the load cell method showed a difference in the low-capacity measurement value and the infrared method in the high-capacity measurement value. As a result of this experiment, there was little difference in accuracy according to the sensor method of the infusion monitoring device, and it is considered that there is no problem in accuracy when used in a medical institution.
참고문헌 (15)
- 김진현, "간호·간병통합서비스 운영성과 및 향후 정책방향", 간호행정학회지, 23(3), pp.312~322 (2017), 간호행정학회[DOI]
- Seyeol Oh, "Serum Lactate, Creatinine and Urine Output: Early Predictors of Mortality after Initial Fluid Resuscitation in Severe Burn Patients", Journal of Korean Burn Society, 23(1), pp.1~6 (2020), Journal of Korean Burn Society[DOI]
- 박정하, "간호대학생을 위한 가상현실(VR) 360도 정맥수액주입 교육용 콘텐츠의 적용", 문화기술의 융합, 6(4), pp.165~170 (2020), 국제문화기술진흥원
- 노은영, "팬데믹 상황에서 음압병실 근무 간호사의 COVID-19 환자 간호 경험", Journal of Korean Academy of Nursing, 51(5), pp.585~596 (2021), 한국간호과학회
- Ha Quang Thinh Ngo, "Research on a Low-Cost, Open-Source, and Remote Monitoring Data Collector to Predict Livestock’s Habits Based on Location and Auditory Information: A Case Study from Vietnam", Agriculture, 10(5), pp.180~ (2020), MDPI AG[DOI]
- A. McGarr, "Maximum magnitude earthquakes induced by fluid injection", Journal of Geophysical Research: Solid Earth, 119(2), pp.1008~1019 (2014), American Geophysical Union (AGU)[DOI]
- 이동필, "최근 의료분쟁 현황, 전망과 유의할 점", 대한내과학회지, 94(3), pp.231~236 (2019), 대한내과학회[DOI]
- Jun KATAOKA, "Effects of mental workload on nurses' visual behaviors during infusion pump operation", Japan Journal of Nursing Science, 8(1), pp.47~56 (2010), Wiley[DOI]
- Y. MAJIMA, "Survey of Actual Conditions of Reasons for Nurse Calls: Comparing a Surgical Ward and a Medical Ward", Connecting Health and Humans (2009)[DOI]
- O.O.E. Ajibola, "Development of automated intravenous blood infusion monitoring system using load cell sensor", Journal of Applied Sciences and Environmental Management, 22(10), pp.1557~ (2018), African Journals Online (AJOL)[DOI]
- 김영철, "종방향 전기장 근접 감지 방식 수액 주입 측정 센서", 센서학회지, 26(2), pp.101~106 (2017), 한국센서학회[DOI]
- Y. Zhang, "Wireless sensor network-enabled intravenous infusion monitoring", IET Wireless Sensor Systems, 1(4), pp.241~247 (2011), Institution of Engineering and Technology (IET)[DOI]
- X. Wen, "Design of Medical Infusion Monitor and Protection System Based On Wireless Communication Technology", Second International Symposium on Intelligent Information Technology Application (2008)
- 정인숙, "간호학생의 약물용량계산능력과 정확도에 관한 융합적 연구", 한국융합학회논문지, 8(3), pp.123~131 (2017), 한국융합학회[DOI]
- 박효순, "수액 소진 알람시스템을 위한 동일평면형 광센서의 연구 및 제작", 센서학회지, 24(2), pp.113~118 (2015), 한국센서학회[DOI]