본문 바로가기
KERD
논문KCI 등재

LG Advansure^(TM) Malaria P.f./P.v. real-time QPCR의 말라리아 진단 유용성

Evaluation of the LG Advansure^(TM) Malaria P.f./P.v. real-time QPCR for the Diagnosis of Malaria

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Background: Malaria is a problematic disease in Korea, and microscopic examination of Giemsa-stained blood smear has been used as the gold standard for its diagnosis. However, this technique is time-consuming and has low sensitivity in samples with low numbers of malarial parasites (<20 parasites/μL). Here, we evaluated the performance characteristics of the LG Advansure^(TM) Malaria P.f./P.v. real-time QPCR (LG life sciences,Korea). Methods: Blood samples from 173 persons who visited Korea University Ansan Hospital were evaluated. QPCR was performed in 73 malaria patients and 100 healthy subjects by using the LG Advansure Malaria P.f./P.v. real-time QPCRR kit, and the results were compared with those of microscopy. The detection limit of this kit was determined by serial dilution of Plasmodium-infected blood with normal blood (blood not infected with Plasmodium). Results: Among the 73 patients that were microscopically confirmed to have malaria (Plasmodium vivax infection, N=70, P. falciparum infection,N=3), 69 patients were diagnosed with P. vivax infection and 3 were diagnosed with P. falciparum infection by LG Advansure^(TM) Malaria P.f./P.v. realtime QPCR. Both the tests indicated absence of infection in the 100 healthy subjects. The detection limit of LG Advansure^(TM)Malaria P.f./P.v. real-time QPCR was 0.1 parasite/μL. Conclusions: LG Advansure^(TM Malaria P.f./P.v. real-time QPCRis a very sensitive and specific technique and can be used as a confirmatory test for malaria.

Abstract

Background: Malaria is a problematic disease in Korea, and microscopic examination of Giemsa-stained blood smear has been used as the gold standard for its diagnosis. However, this technique is time-consuming and has low sensitivity in samples with low numbers of malarial parasites (<20 parasites/μL). Here, we evaluated the performance characteristics of the LG Advansure^(TM) Malaria P.f./P.v. real-time QPCR (LG life sciences,Korea). Methods: Blood samples from 173 persons who visited Korea University Ansan Hospital were evaluated. QPCR was performed in 73 malaria patients and 100 healthy subjects by using the LG Advansure Malaria P.f./P.v. real-time QPCRR kit, and the results were compared with those of microscopy. The detection limit of this kit was determined by serial dilution of Plasmodium-infected blood with normal blood (blood not infected with Plasmodium). Results: Among the 73 patients that were microscopically confirmed to have malaria (Plasmodium vivax infection, N=70, P. falciparum infection,N=3), 69 patients were diagnosed with P. vivax infection and 3 were diagnosed with P. falciparum infection by LG Advansure^(TM) Malaria P.f./P.v. realtime QPCR. Both the tests indicated absence of infection in the 100 healthy subjects. The detection limit of LG Advansure^(TM)Malaria P.f./P.v. real-time QPCR was 0.1 parasite/μL. Conclusions: LG Advansure^(TM Malaria P.f./P.v. real-time QPCRis a very sensitive and specific technique and can be used as a confirmatory test for malaria.

참고문헌 (17)

  1. Sinden R, "Essential malariology" (2002), Arnold
  2. Gama BE, "Real-time PCR versus conventional PCR for malaria parasite detection in low-grade parasitemia", Exp Parasitol, 116, pp.427~432 (2007)
  3. Park J, "Two cases of falciparum malaria with acute respiratory distress syndrome", Tuberc Respir Dis, 45, pp.888~895 (1998)
  4. Cho YH, "Transfusion–transmitted malaria in Korea–10 cases during 1997-2001", Korean J Blood Transfus, 12, pp.263~270 (2001)
  5. WHO, "Guidelines for the treatment of malaria", pp.10~11 (2010), WHO
  6. Amexo M, "Malaria misdiagnosis: effects on the poor and vulnerable", Lancet, 364, pp.1896~1898 (2004)
  7. Vo TK, "Evaluation of a real-time PCR assay for malaria diagnosis in patients from Vietnam and in returned travellers", Trans R Soc Trop Med Hyg, 101, pp.422~428 (2007)
  8. Farcas GA, "Evaluation of the RealArt Malaria LC real-time PCR assay for malaria diagnosis", J Clin Microbiol, 42, pp.636~638 (2004)
  9. Rougemont M, "Detection of four Plasmodium species in blood from humans by 18S rRNA gene subunit-based and species-specific real-time PCR assays", J Clin Microbiol, 42, pp.5636~5643 (2004)
  10. Hanscheid T, "How useful is PCR in the diagnosis of malaria", Trends Parasitol, 18, pp.395~398 (2002)
  11. Moody A, "Rapid diagnostic tests for malaria parasites", Clin Microbiol Rev, 15, pp.66~78 (2002)
  12. Lim HS, "Evaluation of diagnostic methods of re-emerging malaria in Korean patients", Yonsei Med J, 42, pp.84~90 (2001)
  13. Snounou G, "Identification of the four human malaria parasite species in field samples by the polymerase chain reaction and detection of a high prevalence of mixed infections", Mol Biochem Parasitol, 58, pp.283~292 (1993)
  14. Calderaro A, "Evaluation of a new plate hybridization assay for the laboratory diagnosis of imported malaria in Italy", New Microbiol, 27, pp.163~171 (2004)
  15. Mehlotra RK, "Random distribution of mixed species malaria infections in Papua New Guinea", Am J Trop Med Hyg, 62, pp.225~231 (2000)
  16. Padley DJ, "Establishment of the 1st World Health Organization International Standard for Plasmodium falciparum DNA for nucleic acid amplification technique (NAT)-based assays", Malar J, 7, pp.139~ (2008), Collaborative Study Group
  17. Vu TT, "Screening donor blood for malaria by polymerase chain reaction", Trans R Soc Trop Med Hyg, 89, pp.44~47 (1995)

관련 논문AI추천

이 간행물의 다른 논문 (8건)