사람면역결핍바이러스감염 환자에서 2색 및 4색 유세포분석법을 이용한 T 림프구아형 분석
Methods for Flow Cytometric Analysis of T Cell Subsets in HIV-infected Patients: 2-Color versus 4-Color
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: Blood CD4+ T-lymphocyte (T4) count is a major clinical marker for the diagnosis and management of AIDS, and flow cytometry is considered the gold standard for T4 enumeration. Our aim was to compare the 2-color and 4-color flow cytometric methods for T-cell subset analysis in HIV-infected patients. Methods: T-cell subsets such as T3, T4, T8, and CD3+CD4-CD8- double negative T cells (DN T) were analyzed from the whole blood of 40 HIV-infected patients by using both 2-color and 4-color methods on a Cytomics FC500 analyzer. Statistical analyses using simple linear regression, paired t-tests, and Bland-Altman plots were performed. Results: The measured T3 (%), T4 (%), T4 (/μL), T8 (%), T8 (/μL), and DN T (%) differed significantly between the 2 methods (P<0.05), whereas the T4/T8 ratio did not. T3 (%), T4 (%), T4 (/μL), T8 (%), T8 (/μL), and T4/T8 measured by the 2 methods showed good correlation, with correlation coefficients above 0.96, whereas DN T (%) did not. The mean differences in T4 (%) and T8 (%) were 0.39% (limit of agreement (LoA), -1.64~2.43) and 1.26% (LoA, -3.37~5.89), respectively. Conclusions: Although there were statistically significant differences in the T cell subsets measured between the 2 methods, the differences were minor, and the 2 methods showed good correlation. As confirmed in this study, DN T (%) estimated by the 2-color method is lower than the actual value. We suggest that although the 2 methods can be used interchangeably, the 4-color method is recommended for the analysis of some specific subpopulations such as DN T (%).
Abstract
Background: Blood CD4+ T-lymphocyte (T4) count is a major clinical marker for the diagnosis and management of AIDS, and flow cytometry is considered the gold standard for T4 enumeration. Our aim was to compare the 2-color and 4-color flow cytometric methods for T-cell subset analysis in HIV-infected patients. Methods: T-cell subsets such as T3, T4, T8, and CD3+CD4-CD8- double negative T cells (DN T) were analyzed from the whole blood of 40 HIV-infected patients by using both 2-color and 4-color methods on a Cytomics FC500 analyzer. Statistical analyses using simple linear regression, paired t-tests, and Bland-Altman plots were performed. Results: The measured T3 (%), T4 (%), T4 (/μL), T8 (%), T8 (/μL), and DN T (%) differed significantly between the 2 methods (P<0.05), whereas the T4/T8 ratio did not. T3 (%), T4 (%), T4 (/μL), T8 (%), T8 (/μL), and T4/T8 measured by the 2 methods showed good correlation, with correlation coefficients above 0.96, whereas DN T (%) did not. The mean differences in T4 (%) and T8 (%) were 0.39% (limit of agreement (LoA), -1.64~2.43) and 1.26% (LoA, -3.37~5.89), respectively. Conclusions: Although there were statistically significant differences in the T cell subsets measured between the 2 methods, the differences were minor, and the 2 methods showed good correlation. As confirmed in this study, DN T (%) estimated by the 2-color method is lower than the actual value. We suggest that although the 2 methods can be used interchangeably, the 4-color method is recommended for the analysis of some specific subpopulations such as DN T (%).
참고문헌 (18)
- Fahey JL, "The prognostic value of cellular and serologic markers in infection with human immunodeficiency virus type 1", N Engl J Med, 322, pp.166~172 (1990)
- Fauci AS, "NIH conference. Acquired immunodeficiency syndrome: epidemiologic, clinical, immunologic, and therapeutic consideration", Ann Intern Med, 100, pp.92~106 (1984)
- Hammer SM, "Antiretroviral treatment of adult HIV infection: 2008 recommendations of the International AIDS society-USA panel", JAMA, 300, pp.555~570 (2008)
- O’Brien WA, "Changes in plasma HIV-1 RNA and CD4+ lymphocyte counts and the risk of progression to AIDS. Veterans Affairs Cooperative Study Group on AIDS", N Engl J Med, 334, pp.426~431 (1996)
- AIDS, "Laboratory guidelines for enumerating CD4 T lymphocytes in the context of HIV", pp.2007, World Health Organization
- Bergeron M, "Selection of lymphocyte gating protocol has impact on the level of reliability of T-cell subsets in aging specimens", Cytometry, 50, pp.53~61 (2002)
- Bland JM, "Statistical methods for assessing agreement between two methods of clinical measurement", Lancet, 1, pp.307~310 (1986)
- UNAIDS and World Health Organization., "Progress on global access to HIV antiretroviral therapy: a report on “3 by 5” and beyond", pp.24~25 (2006), WHO press
- Annual report on the notified HIV, "AIDS in Korea", Korea Centers for Disease Control and Prevention, 2012, pp.14~
- "D’Acquisto F and Crompton T. CD3+CD4-CD8- (double negative) T cells: saviours or villains of the immune response?", Biochem Pharmacol, 82, pp.333~340 (2011)
- Sundaravaradan V, "Double-negative T cells during HIV", SIV infections: potential pinch hitters in the T-cell lineup, 2012, pp.7, 164~171
- Fletcher MA, "Use of whole blood methods in assessment of immune parameters in immunodeficiency states", Diagn Clin Immunol, 5, pp.69~81 (1987)
- Nicholson JK, "CD4 T-lymphocyte determinations on whole blood specimens using a single-tube three-color assay", Cytometry, 14, pp.685~689 (1993)
- Nicholson J, "Three-color supplement to the NIAID DAIDS guideline for flow cytometric immunophenotyping", Cytometry, 26, pp.227~230 (1996)
- Kutok JL, "Four-color flow cytometric immunophenotypic determination of peripheral blood CD4+ T lymphocyte counts: a comparison of validity and cost-effectiveness with a two-color method", Am J Clin Pathol, 110, pp.465~470 (1998)
- Mbopi-Kéou FX, "Validation of a single-platform, volumetric, CD45-assisted PanLeucogating Auto40 flow cytometer to determine the absolute number and percentages of CD4 T cells in resource-constrained settings using Cameroonian patients’ samples", Clin Vaccine Immunol, 19, pp.609~615 (2012)
- Clinical and Laboratory Standards Institute, "Enumeration of immunologically defined cell populations by flow cytometry; approved guideline. 2nd ed. EP5-A2", Clinical and Laboratory Standards Institute, ~ (2007)
- Luider J, "Impact of the new Beckman Coulter Cytomics FC 500 5-color flow cytometer on a regional flow cytometry clinical laboratory service", Lab Hematol, 10, pp.102~108 (2004)
