체액 및 요검체 접종을 위한 자동 접종장비 PREVI Isola^®의 유용성 평가

Evaluation of an Automated Instrument, PREVI Isola^® for Inoculation of Body Fluids and Urine Samples onto Agar Plates

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Background: In most clinical microbiology laboratories, inoculation of specimens on plates is performed manually and is a time-consuming process. The efficiency of this process can be improved by using an automated instrument. Currently, several automated instruments have been introduced for inoculation of samples. In this study, we have evaluated an automated instrument, PREVI Isola^® (Biomerieux, France), used for inoculation of body fluids and urine specimens. Methods: Both manual and automated instrument methods were used to inoculate 74 body fluid and 204 urine samples. Precision was evaluated by testing 3 types of urine samples (A, 6×103 colony-forming units (CFU)/mL; B, 3×104 CFU/mL; and C, >106 CFU/mL) in replicates of 20. Results of the 2 methods were compared by counting the isolated colonies on agar plates after incubation. The time required for both methods was also compared. Results: The coefficient of variation (CV) of samples A, B, and C examined using the automated instrument method was 176.1%, 18.1%, and 12.6%,respectively. The sensitivity and specificity of testing body fluid samples were 77% and 100%, respectively, and those of urine samples were 87%each. The time required for testing 15 body fluid specimens and that for inoculation of each specimen was 9.7 min shorter using PREVI Isola^® than using the manual method. Conclusions: The results of body fluid and urine culture by inoculation using the automated instrument, PREVI Isola^®, showed relative good agreement with those obtained using the manual method. The use of PREVI Isola^® would be expected to reduce the time and labor involved in inoculating various kinds of specimens.

Abstract

Background: In most clinical microbiology laboratories, inoculation of specimens on plates is performed manually and is a time-consuming process. The efficiency of this process can be improved by using an automated instrument. Currently, several automated instruments have been introduced for inoculation of samples. In this study, we have evaluated an automated instrument, PREVI Isola^® (Biomerieux, France), used for inoculation of body fluids and urine specimens. Methods: Both manual and automated instrument methods were used to inoculate 74 body fluid and 204 urine samples. Precision was evaluated by testing 3 types of urine samples (A, 6×103 colony-forming units (CFU)/mL; B, 3×104 CFU/mL; and C, >106 CFU/mL) in replicates of 20. Results of the 2 methods were compared by counting the isolated colonies on agar plates after incubation. The time required for both methods was also compared. Results: The coefficient of variation (CV) of samples A, B, and C examined using the automated instrument method was 176.1%, 18.1%, and 12.6%,respectively. The sensitivity and specificity of testing body fluid samples were 77% and 100%, respectively, and those of urine samples were 87%each. The time required for testing 15 body fluid specimens and that for inoculation of each specimen was 9.7 min shorter using PREVI Isola^® than using the manual method. Conclusions: The results of body fluid and urine culture by inoculation using the automated instrument, PREVI Isola^®, showed relative good agreement with those obtained using the manual method. The use of PREVI Isola^® would be expected to reduce the time and labor involved in inoculating various kinds of specimens.

참고문헌 (10)

  1. Woods GL, "Automation in clinical microbiology", Am J Clin Pathol, 98, pp.22~30 (1992)
  2. Bourbeau PP, "First evaluation of the WASP, a new auto mated microbiology plating instrument", J Clin Microbiol, 47, pp.1101~1106 (2009)
  3. Glasson JH, "Evaluation of an automated instrument for inoculating and spreading samples onto agar plates", J Clin Microbiol, 46, pp.1281~1284 (2008)
  4. Albers AC, "Accuracy of calibrated-loop transfer", J Clin Microbiol, 18, pp.40~42 (1983)
  5. Chong Y, "Diagnostic Microbiology", pp.58~113 (2009), Seoheung Publishing Company
  6. Clinical and Laboratory Standards Institute, "Evaluation of the precisionperformance of clinical chemistry devices; approved guideline, In Document EP05-A2" (2004), Clinical and Laboratory Standards Institute
  7. Isenberg HD, "Clinical microbiology procedures handbook" (2004), American Society for Microbiology
  8. Kass EH, "Asymptomatic infections of the urinary tract. 1956", J Urol, 167, pp.1016~1019 (2002)
  9. Tilton RC, "Evaluation of an automated agar plate streaker", J Clin Microbiol, 7, pp.298~304 (1978)
  10. Scarparo C, "Evaluation of the DipStreak, a new device with an original streaking mechanism for detection, counting, and presumptive identification of urinary tract pathogens", 40, pp.2169~2175 (2002)

관련 논문AI추천

혈액배양 검체 접종을 위한 Previ Isola® 시스템과 수기법의 비교평가구선회, 권계철, 김지명, 박영춘, 윤진상대한진단검사의학회 · Laboratory Medicine Online2016 · 제6권 제1호자동혈액배양법을 이용한 혈액 이외 체액배양의 평가강정옥, 배현주, 최태열대한임상미생물학회 · Annals of Clinical Microbiology2011 · 제14권 제1호Evaluation of the Impact of Automated Specimen Inoculation, Using Previ Isola, on the Quality of and Technical Time for Stool CulturesAlexander Mischnik, Marlies Trampe, Stefan Zimmermann대한진단검사의학회 · Annals of Laboratory Medicine2015 · 제35권 제1호Multicenter Evaluation of an Image Analysis Device (APAS): Comparison Between Digital Image and Traditional Plate Reading Using Urine CulturesDianne Olden, Fotula Papadopoulos, John Glasson, Michael Summerford, Rhys Hill, Stephen Young, Steven Giglio대한진단검사의학회 · Annals of Laboratory Medicine2017 · 제37권 제6호Evaluation of the impact of automated specimen inoculation using Previ Isola for stool cultures on quality and technical time of culturesAlexander Mischnik, Marlies Trampe, Stefan Zimmermann대한진단검사의학회 · Annals of Laboratory Medicine2015 · 제35권 제2호Comparison of Clinical Performance Between BacT/ Alert Virtuo and BacT/Alert 3D Blood Culture Systems김선주, 김성춘, 박현웅, 유성미, 이승준, 조오현대한진단검사의학회 · Annals of Laboratory Medicine2019 · 제39권 제3호

이 간행물의 다른 논문 (8건)