본문 바로가기
KERD
논문KCI 등재

비인두면봉 검체에서 호흡기바이러스 검출을 위한 ExiPrep16 자동핵산추출기 평가

Evaluation of ExiPrep16 Automated System for the Extraction of Nucleic Acids from Nasopharyngeal Swabs for the Detection of Respiratory Viruses

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Background: Automated nucleic acid extraction offers a standardized sample treatment method, low error rate, and avoids sample nucleic acid contamination for use in molecular diagnostics. Here, we evaluated the performance of automated ExiPrep16 system (Bioneer Co.) in comparison with the manual Viral Gene-spin Viral DNA/RNA Extraction kit (VGspin; iNtRON Biotechnology Inc.) for the detection of respiratory viruses from nasopharyngeal flocked swabs. Methods: To compare the agreement rate and analytical sensitivity between ExiPrep16 and VGspin, previously collected 78 patient samples and 11 pooled samples of each respiratory viruses and their serially diluted samples (until 1/108), were tested by multiplex reverse-transcriptase PCR (Seeplex RV 12 ACE Detection kit; SeeGene Inc.). In addition, we repeatedly analyzed the threshold cycle of the pooled and 1/103 dilution of adenovirus (ADV) and influenza virus A (Flu-A) by using real-time PCR to evaluate the precision and crossover of the ExiPrep16 system. Results: The analytical sensitivity of the ExiPrep16 was comparable to that of VGspin, and the highest detectable dilution varied in the range of 1/10 to 1/106 depending on the viruses. The total, overall positive and negative percent agreements of ExiPrep16 in comparison with VGspin were 95.7%, 96.2%, and 95.2%, respectively. The mean (CV%) of pooled and 1/103 dilution of ADV were, respectively, 19.2 cycle (2.1%) and 31.6 cycle (4.3%) and those for Flu-A were 22.6 cycle (3.1%) and 35.5 cycle (2.6%). No carryover was detected. Conclusions: Compared to the manual VGspin, ExiPrep16 ensured nucleic acid extraction for efficient detection of respiratory viruses.

Abstract

Background: Automated nucleic acid extraction offers a standardized sample treatment method, low error rate, and avoids sample nucleic acid contamination for use in molecular diagnostics. Here, we evaluated the performance of automated ExiPrep16 system (Bioneer Co.) in comparison with the manual Viral Gene-spin Viral DNA/RNA Extraction kit (VGspin; iNtRON Biotechnology Inc.) for the detection of respiratory viruses from nasopharyngeal flocked swabs. Methods: To compare the agreement rate and analytical sensitivity between ExiPrep16 and VGspin, previously collected 78 patient samples and 11 pooled samples of each respiratory viruses and their serially diluted samples (until 1/108), were tested by multiplex reverse-transcriptase PCR (Seeplex RV 12 ACE Detection kit; SeeGene Inc.). In addition, we repeatedly analyzed the threshold cycle of the pooled and 1/103 dilution of adenovirus (ADV) and influenza virus A (Flu-A) by using real-time PCR to evaluate the precision and crossover of the ExiPrep16 system. Results: The analytical sensitivity of the ExiPrep16 was comparable to that of VGspin, and the highest detectable dilution varied in the range of 1/10 to 1/106 depending on the viruses. The total, overall positive and negative percent agreements of ExiPrep16 in comparison with VGspin were 95.7%, 96.2%, and 95.2%, respectively. The mean (CV%) of pooled and 1/103 dilution of ADV were, respectively, 19.2 cycle (2.1%) and 31.6 cycle (4.3%) and those for Flu-A were 22.6 cycle (3.1%) and 35.5 cycle (2.6%). No carryover was detected. Conclusions: Compared to the manual VGspin, ExiPrep16 ensured nucleic acid extraction for efficient detection of respiratory viruses.

참고문헌 (14)

  1. Mahony JB, "Detection of respiratory viruses by molecular methods", Clin Microbiol Rev, 21, pp.716~747 (2008)
  2. 이재훈, "Evaluation of Direct Immunofluorescence Test with PCR for Detection of Novel Influenza A (H1N1) Virus during 2009 Pandemic", Yonsei Medical Journal, 52(4), pp.680~682 (2011), 연세대학교의과대학
  3. Chan KH, "Comparison of the NucliSens easyMAG and Qiagen BioRobot 9604 nucleic acid extraction systems for detection of RNA and DNA respiratory viruses in nasopharyngeal aspirate samples", J Clin Microbiol, 46, pp.2195~2199 (2008)
  4. Espy MJ, "Real-time PCR in clinical microbiology: applications for routine laboratory testing", Clin Microbiol Rev, 19, pp.165~256 (2006)
  5. Riemann K, "Comparison of manual and automated nucleic acid extraction from whole-blood samples", J Clin Lab Anal, 21, pp.244~248 (2007)
  6. Beuselinck K, "Automated extraction of viral- pathogen RNA and DNA for high-throughput quantitative real-time PCR", J Clin Microbiol, 43, pp.5541~5546 (2005)
  7. Aldous WK, "Comparison of six methods of extracting Mycobacterium tuberculosis DNA from processed sputum for testing by quantitative real-time PCR", J Clin Microbiol, 43, pp.2471~2473 (2005)
  8. Thakur R, "Comparison of DNA extraction protocols for Mycobacterium Tuberculosis in diagnosis of tuberculous meningitis by real-time polymerase chain reaction", J Glob Infect Dis, 3, pp.353~356 (2011)
  9. Kohdera U, "Detection of adenovirus DNA in throat swabs and blood by SYBR green real-time PCR assay in patients with adenovirus-associated tonsillitis", Jpn J Infect Dis, 59, pp.394~396 (2006)
  10. Clinical and Laboratory Standards Institute, "User protocol for evaluation of qualitative test performance; approved guideline. 2nd ed, EP12-A2", Clinical and Laboratory Standards Institute, ~ (2008)
  11. Clinical and Laboratory Standards Institute, "Evaluation of precision performance of quantitative measurement methods; approved guideline. 2nd ed, EP5-A2", Clinical and Laboratory Standards Institute, ~ (2004)
  12. 윤귀현, "소아에서 다중 역전사효소 PCR법, 직접면역형광법, 쉘바이알배양법을 이용한 호흡기 바이러스의 검출", Annals of Clinical Microbiology, 12(3), pp.110~115 (2009), 대한임상미생물학회
  13. 유수진, "Dual Priming Oligonucleotide System을 이용한 다중 역전사 PCR 키트를 통한 12가지 호흡기 바이러스의 검출", Annals of Laboratory Medicine, 27(6), pp.420~427 (2007), 대한진단검사의학회
  14. 조지현, "B형 간염 바이러스 실시간 정량법(RealArt HBV LC PCR)의 평가", Annals of Clinical Microbiology, 10(1), pp.25~31 (2007), 대한임상미생물학회

관련 논문AI추천

Comparison of Multiplex Real-Time Polymerase Chain Reaction Assays for Detection of Respiratory Viruses in Nasopharyngeal Specimens김대원, 김민경, 변정현, 용동은, Jean Damascene Uwizeyimana대한임상미생물학회 · Annals of Clinical Microbiology2019 · 제22권 제2호사람호흡기바이러스검출에 대한 다중PCR과 단일PCR의 성능 비교김솔잎, 엄기원, 엄태현, 조종래대한진단검사의학회 · Laboratory Medicine Online2016 · 제6권 제4호Evaluation of the AccuPower® RV1 Real-Time RT-PCR Kit and the AccuPower® RV1 Multiplex Kit for SARS-CoV-2 and Influenza Virus Detection김만진, 김보람, 박성섭, 박현웅, 성문우, 신호섭, 이지수, 전유라, 조성임대한진단검사의학회 · Laboratory Medicine Online2021 · 제11권 제4호Evaluation of a Multiplex Real-time PCR Assay for the Detection of Respiratory Viruses in Clinical Specimens김종완, 김태현, 박주원, 임인수대한진단검사의학회 · Annals of Laboratory Medicine2012 · 제32권 제6호Evaluation of the AdvanSure One-Stop COVID-19 Plus Kit for SARS-CoV-2 Detection Using a Streamlined RNA Extraction Method이남용, 허희재, Jang Ja-Hyun, Jeong Eunjung, Kang Minhee, Kim Tae Yeul, Shim Hyang Jin대한진단검사의학회 · Annals of Laboratory Medicine2023 · 제43권 제5호인플루엔자 A 및 A/H1N1/2009 균주 검출을 위한 Cepheid Xpert Flu의 평가기창석, 김지연, 박경선, 손지연, 이남용대한임상미생물학회 · Annals of Clinical Microbiology2013 · 제16권 제3호

이 간행물의 다른 논문 (10건)