본문 바로가기
KERD
논문KCI 등재

소형 GC 모듈의 개발 및 특성

Development and Characteristic Study of a Portable Gas Chromatography

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류화학

초록

In the present study, we developed a portable GC module for real-time, quantitative determinations of gas mixtures in air sample. Capillary or packed column was coiled together with a heater wire and thermocouple in a small case. Together with the small and light weight sensors and valves as well as the rechargeable carrier gas canister, which permits collection and separation of samples, this system can determine the components of complex mixtures of air contaminants at low concentrations with a duty cycle of 10 min. When measured the various samples with a FID and TCD, the system showed,for a capillary column, a good resolution (R=8.3), high sensitivity, reproducibility, and linear dynamic range greater than three orders of magnitude. These results indicate that the portable GC module is expected to be used for a wide range of applications,particularly for in situ environmental monitoring, chemical processes, and regulation of contaminant emission.

Abstract

In the present study, we developed a portable GC module for real-time, quantitative determinations of gas mixtures in air sample. Capillary or packed column was coiled together with a heater wire and thermocouple in a small case. Together with the small and light weight sensors and valves as well as the rechargeable carrier gas canister, which permits collection and separation of samples, this system can determine the components of complex mixtures of air contaminants at low concentrations with a duty cycle of 10 min. When measured the various samples with a FID and TCD, the system showed,for a capillary column, a good resolution (R=8.3), high sensitivity, reproducibility, and linear dynamic range greater than three orders of magnitude. These results indicate that the portable GC module is expected to be used for a wide range of applications,particularly for in situ environmental monitoring, chemical processes, and regulation of contaminant emission.

참고문헌 (12)

  1. Hodgson, M., , Occup. Med, 15, pp.571~ (2000)
  2. Smedbold, H. T, , Indoor Air, 11, pp.23~ (2001)
  3. Wolkoff, P., , Indoor Air, (3), pp.9~73 (1995)
  4. J. J. Isbell, , J. Am. Soc. Mass Spectrom, 7, pp.565~ (1996)
  5. Burton, B., "Volatile Organic Compounds In Indoor Air Pollution and Health", pp.127~153 (1997), Marcel Dekker
  6. Peng, C. Y., , J. Environ. Monit, 2, pp.213~ (2000)
  7. Wahl, J. H., , J. Sep. Sci, 26, pp.1083~ (2003)
  8. Smith, P. A., , J. Chromatogr. A, 1067, pp.285~ (2005)
  9. Agah, M., , J. Microelectromech. Syst, 14, pp.1039~ (2005)
  10. Whiting, J. J., , J. Sep. Sci, 29, pp.218~ (2006)
  11. Kim, M. G., , J. Korean Chem. Soc, 38, pp.151~ (1994)
  12. Lee, J.-H., , Bull. Korean Chem. Soc, 23, pp.488~ (2002)

관련 논문AI추천

휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가김현식, 선영식, 오준식, 유동욱, 이봉윤, 정광우대한화학회 · 대한화학회지2020 · 제64권 제6호저온농축장치를 이용한 NMHCs의 측정법과 가스 시료에 적용김수하, 김진석, 문동민한국분석과학회 · 분석과학2012 · 제25권 제6호Analysis Method of Volatile Sulfur Compounds Utilizing Separation Column and Metal Oxide Semiconductor Gas Sensor김인호, 김한수, 박은덕, 한상도한국센서학회 · 센서학회지2024 · 제33권 제3호Development of primary reference gas mixtures of 18 volatile organic compounds in hazardous air pollutants (5 nmol/mol level) and their analytical methods이상일, Ji Hwan Kang, Jin-Hong Lee, Yong Doo Kim한국분석과학회 · 분석과학2021 · 제34권 제5호GC/MS를 이용한 VOC 성분의 주입방식별 검량특성에 대한 연구김기현, 안지원한국환경분석학회 · 환경분석과 독성보건2009 · 제12권 제1호Development and validation of a portable gas chromatograph method for quantitative determination of oxygen and toxic gas impurities in medical oxygen using planar microchromatographic columns and detectorsAlexander l. Khokhlov, Dmitry A. Semanov, Dmitry V. Somov, Ekaterina V. Galeeva, Ilshat R. Aryslanov, Natalia А. Lezhnina, Nishant Tripathi, Prachi Sharma, Roman R. Galeev, Vladimir Platonov한국분석과학회 · 분석과학2024 · 제37권 제5호

이 간행물의 다른 논문 (26건)