본문 바로가기
KERD
논문KCI 등재

Development of primary reference gas mixtures of 18 volatile organic compounds in hazardous air pollutants (5 nmol/mol level) and their analytical methods

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류화학

초록

Volatile organic compounds (VOCs) in hazardous air pollutants (HAPs) have been regulated by the Air Pollution Control Act (1978) and their atmospheric concentrations have been monitored in 39 monitor sites in Korea. However, measurement standards of volatile organic compounds (VOCs) in HAPs at ambient levels have not been established in Korea. Primary reference gas mixtures (measurement standards) at ambient levels are required for accurately monitoring atmospheric VOCs in HAPs and managing their emissions. In this study, primary reference gas mixtures (PRMs) at 5 nmol/mol were developed in order to establish primary national standards of VOCs in HAPs at ambient levels. Primary reference gas mixtures (PRMs) were prepared in pressurized aluminum cylinders with special internal surface treatment using gravimetric method. Analytical methods using gas chromatography-flame ionization detector (GC-FID) coupled with a cryogenic preconcentrator were also developed to verify the consistency of gravimetrically prepared HAP VOCs PRMs. Three different columns installed in the GC-FID were evaluated and compared for the retention times and separation of eighteen target components in a chromatogram. Results show that the HAP VOCs PRMs at 5 nmol/mol were consistent within a relative expanded uncertainty (k=2) of less than 3 % except acrylonitrile (less than 6 %) and the 18 VOCs were stable for 1 year within their associated uncertainties.

Abstract

Volatile organic compounds (VOCs) in hazardous air pollutants (HAPs) have been regulated by the Air Pollution Control Act (1978) and their atmospheric concentrations have been monitored in 39 monitor sites in Korea. However, measurement standards of volatile organic compounds (VOCs) in HAPs at ambient levels have not been established in Korea. Primary reference gas mixtures (measurement standards) at ambient levels are required for accurately monitoring atmospheric VOCs in HAPs and managing their emissions. In this study, primary reference gas mixtures (PRMs) at 5 nmol/mol were developed in order to establish primary national standards of VOCs in HAPs at ambient levels. Primary reference gas mixtures (PRMs) were prepared in pressurized aluminum cylinders with special internal surface treatment using gravimetric method. Analytical methods using gas chromatography-flame ionization detector (GC-FID) coupled with a cryogenic preconcentrator were also developed to verify the consistency of gravimetrically prepared HAP VOCs PRMs. Three different columns installed in the GC-FID were evaluated and compared for the retention times and separation of eighteen target components in a chromatogram. Results show that the HAP VOCs PRMs at 5 nmol/mol were consistent within a relative expanded uncertainty (k=2) of less than 3 % except acrylonitrile (less than 6 %) and the 18 VOCs were stable for 1 year within their associated uncertainties.

참고문헌 (20)

  1. "OECD Environmental Outlook to 2050"[URL]
  2. "Air pollution"[URL]
  3. "National Air Quality: Status and Trends of Key Air Pollutants"[URL]
  4. H. Mayer, , Atmos. Environ, 33, pp.4029~4037 (1999)
  5. M. Darçın, , Environ. Sci. Pollut. Res, 21(3), pp.1954~1959 (2014)
  6. "Hazardous air pollutants"[URL]
  7. "Enforcement rule of Clean Air Conservation Act"[URL]
  8. A. S. Rosenbaum, , J. Air Waste Manag. Assoc, 49, pp.1138~1152 (1999)
  9. C. C. Travis, , Environ. Sci. Technol, 25, pp.815~818 (1991)
  10. M. Kampa, , Environ. Pollut, 151, pp.362~367 (2008)
  11. D. W. Dockery, , Annu. Rev. Public Health, 15, pp.107~132 (1994)
  12. 서영교, "환경대기 중 유해성 VOC 측정에 관한 동향과 전망", 한국대기환경학회지, 27(6), pp.734~745 (2011), 한국대기환경학회
  13. Korea Ministry of Environment (Korea MOE), "Air Pollution Measurement Installation Operating Instructions", 52~ (2021)
  14. 강지환, "유해대기오염물질 중 14종의 휘발성유기화합물 1차 표준가스개발 (1 μmol", mol 수준 ), 2018, pp.34(2), 331~341[DOI]
  15. 전신배, "휘발성유기화합물 1차 표준가스 (5 nmol mol-1) 흡착손실 평가", 환경분석과 독성보건, 23(1), pp.47~54 (2020), 한국환경분석학회[DOI]
  16. International Organization for Standardization, "ISO 6142-1, Gas analysis - Preparation of Calibration Gas Mixtures - Part 1: Gravimetric Method of Class I Mixtures", ~ (2015)
  17. G. C. Rhoderick, , Anal. Bioanal. Chem, 383, pp.98~106 (2005)
  18. 김미언, "Long-Term Stability Evaluation of 0.5-7.0 nmol", mol Dimethyl Sulfide Primary Standard Gas Mixtures by Comparison with Traceable Dynamically Diluted Gas Mixtures, 2018, pp.39(3), 305~312[DOI]
  19. M. E. Kim, , Talanta, 150, pp.516~524 (2016)
  20. C. F. Poole, , J. Chromatogr. A, 1184, pp.254~280 (2008)

관련 논문AI추천