본문 바로가기
KERD
논문KCI 등재

Analysis Method of Volatile Sulfur Compounds Utilizing Separation Column and Metal Oxide Semiconductor Gas Sensor

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

Gas chromatography (GC) separation technology and metal oxide semiconductor (MOS) gas sensors have been integrated for theeffective analysis of volatile sulfur compounds (VSCs) such as H2S, CH3SH, (CH3)2S, and (CH3)2S2. The separation and detection characteristics of the GC/MOS system using diluted standard gases were investigated for the qualitative and quantitative analysis of VSCs. The typical concentrations of the standard gases were 0.1, 0.5, 1.0, 5.0, and 10.0 ppm. The GC/MOS system successfully separated H2S,CH3SH, (CH3)2S, and (CH3)2S2 using a celite-filled column. The reproducibility of the retention time measurements was at a 3% relativestandard deviation level, and the correlation coefficient (R2) for the VSC concentration was greater than 0.99. In addition, the chromatograms of single and mixed gases were almost identical.

Abstract

Gas chromatography (GC) separation technology and metal oxide semiconductor (MOS) gas sensors have been integrated for theeffective analysis of volatile sulfur compounds (VSCs) such as H2S, CH3SH, (CH3)2S, and (CH3)2S2. The separation and detection characteristics of the GC/MOS system using diluted standard gases were investigated for the qualitative and quantitative analysis of VSCs. The typical concentrations of the standard gases were 0.1, 0.5, 1.0, 5.0, and 10.0 ppm. The GC/MOS system successfully separated H2S,CH3SH, (CH3)2S, and (CH3)2S2 using a celite-filled column. The reproducibility of the retention time measurements was at a 3% relativestandard deviation level, and the correlation coefficient (R2) for the VSC concentration was greater than 0.99. In addition, the chromatograms of single and mixed gases were almost identical.

참고문헌 (13)

  1. O. F. Hong, "Characteristics of major offensive odorants emitted from urban stormwater catch basins", Anal. Sci. Technol., 23(4), pp.347~356 (2010)
  2. J. H. Kim, "Analysis of odorous sulfur compounds in air by GC", MS, 2006, pp.9(3), 139~145
  3. S. G. Seo, "Characteristics of sulfur compounds in Yeosu industrial complex", J. Odor Indoor Environ., 2(2), pp.109~116 (2003)
  4. K. H. Kim, "The basic calibration properties of reduced sulfur compounds in air based on gas chromatographic approaches", J. Odor Indoor Environ., 7(3), pp.170~178 (2008)
  5. S. W. Han, "Performance assessment of H2S, NH3, and VOCs sensors for field application", J. Odor Indoor Environ., 18(3), pp.261~271 (2019)
  6. J. W. Choi, "Rapid freshness evaluation of mackerel scomber japoicus using sensor gas chromatography system", Korean J. Fish. Aquatic. Sci., 50(6), pp.837~840 (2017)
  7. M. Hanada, "Portable oral malodor analyzer using highly sensitive In2O3 gas sensor combined with a simple gas chromatography system", Anal. Chim. Acta, 475(1-2), pp.27~35 (2003)
  8. H. S. Kim, "Determination of method detection limit for individual odorous substances using portable GC", MOS system, 2023, pp.22(2), 119~128
  9. H. S. Kim, "Quantitative and qualitative analysis method of odorous substances using a portable GC", MOS system, 2019, pp.18(1), 1~9
  10. S. Y. Oh, "Fast gas chromatography-surface acoustic waver sensor : An effective tool for discrimination and quality control of Lavandula species", Sens. Actuators B Chem., 182, pp.223~231 (2013)
  11. E. J. Staples, "Development of a novel odor measurement system using gas chromatography with surface acoustic wave sensor", J. Air Waste Manag. Assoc., 58(12), pp.1522~1528 (2008)
  12. S. B. Yang, "A study on the distribution of atmospheric concentrations of sulfur compounds by GC", FPD, 2003, pp.16(3), 240~248
  13. B. K. Yoo, "Surface acoustic wave gas sensors by assembling gas chromatography column", J. Sens. Sci. Tech., 16(1), pp.39~43 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (10건)