논문KCI 등재
교정용 미니 임플랜트 고정원과 SWA en masse sliding retraction 시 전치부 치축 조절 요인에 관한 유한요소해석
Factors influencing the axes of anterior teeth during SWA en masse sliding retraction with orthodontic mini-implant anchorage: a finite element study
2
조회
0
다운로드
4
인용
0
참고문헌
주제분류치의학
참고문헌 (21)
- "Controlled space closure with a preadjusted appliance system", 24, pp.251~260 (1990)
- "Initial stress differences between sliding and sectional mechanics with an endosseous implant as anchorage: a 3-dimensional finite element analysis", 71, pp.247~256 (2001)
- "A Comparison between friction and frictionless mechanics with a new typodont simulation system", 119, pp.292~299 (2001)
- "Mechanical principles in orthodontic force control. In Contemporary Orthodontics", pp.326~361 (2000), Mosby
- "Temporary anchorage devices in orthodontics: a paradigm shift", 11, pp.3~9 (2005)
- "Sliding mechanics with microscrew implant anchorage", 74, pp.703~710 (2004)
- "Absolute anchorage in orthodontics: direct and indirect implant-assisted modalities", 34, pp.397~402 (2000)
- "Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage", 33, pp.339~350 (2003)
- "Stress analysis of Multiloop Edgewise Arch Wire with various degree of tip back bend: a study using the finite element method", 30, pp.127~142 (2000)
- "Three-dimensional finite element analyasis of the phenomenon produced during retraction of four maxillary incisors", 25, pp.525~541 (1995)
- "A three-dimensional finite element analysis on the location of center of resistance during intrusion of upper anterior teeth", 27, pp.259~272 (1997)
- "Three-dimentional finite element analysis for stress in the periodontal tissue by orthodontic forces", 92, pp.499~505 (1987)
- "A comparative evaluation of different compensating curves in the lingual and labial techniques using 3D FEM", 123, pp.441~450 (2003)
- "Finite element method for engineer" (2004), Cheongmoongak publishing
- "Finite element analysis using ANSYS" (2001), Kwangmoonkag publishing
- "The thickness of the human periodontal membrane", 24, pp.1260~1267 (1937)
- "Orthodontic treatment using Micro-implant", pp.5~ (2001), Narae publishing
- "Optimum force magnitude for orthodontic tooth movement: a systematic literature review", 73, pp.86~92 (2003)
- "Magnitude of orthodontic fores and rate of bodily tooth movement. An experimental study", 110, pp.16~23 (1996)
- "The vertical location of the center of resistance for maxillary six anterior teeth during retraction using three dimensional finite element analysis", 31, pp.425~438 (2001)
- "Vertical force considerations in differential space closure", 24, pp.678~683 (1990)
관련 논문AI추천
골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석경희문, 김찬년, 성재현대한치과교정학회 · 대한치과교정학회지2003 · 제33권 제5호상악 전치부 후방 견인 시 이동 양상과 응력 분포에 관한삼차원 유한요소법적 연구강성수, 김상철, 김운수, 이수행, 정애진, 조진형, 최희인대한치과교정학회 · 대한치과교정학회지2007 · 제37권 제2호Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position모성서, Jae-Won Song, Joong-Ki Lim, Kee-Joon Lee, Sang-Jin Sung, Youn-Sic Chun대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제4호분절호선법으로 상하악 절치부 압하 시 순측경사도가 미치는 영향에 관한 3차원 유한요소법적 연구김기태, 김동우, 김성식, 손우성, 양훈철대한치과교정학회 · 대한치과교정학회지2003 · 제33권 제4호교정용 미니스크류를 이용한 연속호선과 분절호선의 유한요소분석박영철, 유형석, 이기준, 이언화대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제4호교정용 미니스크류를 이용한 하악 전치 함입 시 변위양상의 3차원 유한요소분석모성서, 박현경, 성의향, 이기준, 전윤식, 조영수대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제6호
이 간행물의 다른 논문 (7건)
Sandblasted large grit, acid etched 표면처리에 따른 교정용 미니 임플랜트의 제거회전력에 관한 연구김성훈, 이근혜, 강윤구, 국윤아, 모성서, 오남희pp. 324-330폴리카보네이트 브라켓 부착 시 결합강도 증진을 위한 표면처리 효과이현정, 황현식, 김년경, 김석필pp. 331-338니켈-티타늄 와이어의 열처리에 따른 부하-변위 특성 변화김광원, 임성훈, 장수호pp. 349-359다양한 교정용 접착제의 표면거칠기와 표면에너지 요소 분석안석준, 남동석, 안효범pp. 360-368수직적 안모유형에 따른 치료 후 교합평면 안정성에 관한 연구박정은, 차경석, 정동화, 이진우pp. 369-379
