본문 바로가기
KERD
논문KCI 등재

Evaluation of the alignment efficiency of nickeltitanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: The aim of this trial was to compare the alignment efficiency and intermaxillary arch dimension changes of nickel-titanium (NiTi) or copper-nickel-titanium (CuNiTi) round archwires with increasing diameters applied sequentially to the mandibular arch. Methods: The initial alignment phase of fixed orthodontic treatment with NiTi or CuNiTi round archwires was studied in a randomly allocated sample of 66 patients. The NiTi group comprised 26 women, 10 men, and the CuNiTi (27oC) group comprised 20 women, 10 men. The eligibility criteria were as follows: anterior mandibular crowding of minimum 6 mm according to Little’s Irregularity Index (LII), treatment requiring no extraction of premolars, 12 to 18 years of age, permanent dentition, skeletal and dental Class I malocclusion. The main outcome measure was the alignment of the mandibular anterior dentition; the secondary outcome measure was the change in mandibular dental arch dimensions during 12 weeks. Simple randomization (allocation ratio 1:1) was used in this single-blind study. LII and mandibular arch dimensions were measured on three-dimensional digital dental models at 2-week intervals. Results: No statistically significant difference was observed between NiTi and CuNiTi according to LII (p > 0.05). Intercanine and intermolar arch perimeters increased in the CuNiTi group (p < 0.001). Inter-first premolar width showed a statistically significant interaction in week × diameter × application (p < 0.05). Conclusions: The effects of NiTi and CuNiTi round archwires were similar in terms of their alignment efficiency. However, the intercanine and intermolar arch perimeters, and the inter-first premolar width changes differed between groups.[Korean J Orthod 2018;48(3):153-162]

Abstract

Objective: The aim of this trial was to compare the alignment efficiency and intermaxillary arch dimension changes of nickel-titanium (NiTi) or copper-nickel-titanium (CuNiTi) round archwires with increasing diameters applied sequentially to the mandibular arch. Methods: The initial alignment phase of fixed orthodontic treatment with NiTi or CuNiTi round archwires was studied in a randomly allocated sample of 66 patients. The NiTi group comprised 26 women, 10 men, and the CuNiTi (27oC) group comprised 20 women, 10 men. The eligibility criteria were as follows: anterior mandibular crowding of minimum 6 mm according to Little’s Irregularity Index (LII), treatment requiring no extraction of premolars, 12 to 18 years of age, permanent dentition, skeletal and dental Class I malocclusion. The main outcome measure was the alignment of the mandibular anterior dentition; the secondary outcome measure was the change in mandibular dental arch dimensions during 12 weeks. Simple randomization (allocation ratio 1:1) was used in this single-blind study. LII and mandibular arch dimensions were measured on three-dimensional digital dental models at 2-week intervals. Results: No statistically significant difference was observed between NiTi and CuNiTi according to LII (p > 0.05). Intercanine and intermolar arch perimeters increased in the CuNiTi group (p < 0.001). Inter-first premolar width showed a statistically significant interaction in week × diameter × application (p < 0.05). Conclusions: The effects of NiTi and CuNiTi round archwires were similar in terms of their alignment efficiency. However, the intercanine and intermolar arch perimeters, and the inter-first premolar width changes differed between groups.[Korean J Orthod 2018;48(3):153-162]

참고문헌 (30)

  1. Yoneyama T, "Shape memory alloys for biomedical applications" (2009), Woodhead Pub.;CRC Press
  2. Karunakara RV, "Nickel titanium wires in orthodontics: a review", J Dent Oral Biosci, 3, pp.40~42 (2012)
  3. Proffit WR, "Contemporary orthodontics" (2007), Mosby Elsevier
  4. McNamara JA, "Orthodontics and dentofacial orthopedics" (2001), Needham Press
  5. Yoneyama T, "Bending properties and transformation temperatures of heat treated Ni-Ti alloy wire for orthodontic appliances", J Biomed Mater Res, 27, pp.399~402 (1993)[DOI]
  6. Santoro M, "Pseudoelasticity and thermoelasticity of nickel-titanium alloys: a clinically oriented review. Part I: temperature transitional ranges", Am J Orthod Dentofacial Orthop, 119, pp.587~593 (2001)[DOI]
  7. Kusy RP, "A review of contemporary archwires: their properties and characteristics", Angle Orthod, 67, pp.197~207 (1997)
  8. Sachdeva R, "Sure-smile: technology-driven solution for orthodontics", Tex Dent J, 119, pp.608~615 (2002)
  9. Gravina MA, "Mechanical properties of NiTi and CuNiTi shape-memory wires used in orthodontic treatment. Part 1: stress-strain tests", Dental Press J Orthod, 18, pp.35~42 (2013)
  10. Sarul M, "Comparison of elastic properties of nickel-titanium orthodontic archwires", Adv Clin Exp Med, 22, pp.253~260 (2013)
  11. O'Brien K, "A clinical trial of aligning archwires", Eur J Orthod, 12, pp.380~384 (1990)[DOI]
  12. Pandis N, "Alleviation of mandibular anterior crowding with copper- nickeltitanium vs nickel-titanium wires: a double-blind randomized control trial", Am J Orthod Dentofacial Orthop, 136, pp.152.e1~152.e7 (2009)
  13. Fernandes LM, "Pain and discomfort experienced after placement of a conventional or a superelastic NiTi aligning archwire. A randomized clinical trial", J Orofac Orthop, 59, pp.331~339 (1998)[DOI]
  14. Abdelrahman RSh, "A clinical comparison of three aligning archwires in terms of alignment efficiency: a prospective clinical trial", Angle Orthod, 85, pp.434~439 (2015)[DOI]
  15. Riley M, "A systematic review of clinical trials of aligning archwires", J Orthod, 36, pp.42~51 (2009)[DOI]
  16. Ong E, "Alignment efficiency and discomfort of three orthodontic archwire sequences: a randomized clinical trial", J Orthod, 38, pp.32~39 (2011)[DOI]
  17. Flores-Mir C, "Attaining a working archwire--which sequence?", Evid Based Dent, 8, pp.48~ (2007)[DOI]
  18. Mandall N, "Which orthodontic archwire sequence? A randomized clinical trial", Eur J Orthod, 28, pp.561~566 (2006)[DOI]
  19. Waters NE, "A rationale for the selection of orthodontic wires", Eur J Orthod, 14, pp.240~245 (1992)[DOI]
  20. Papageorgiou SN, "A systematic review and metaanalysis of experimental clinical evidence on initial aligning archwires and archwire sequences", Orthod Craniofac Res, 17, pp.197~215 (2014)[DOI]
  21. Sandhu SS, "Efficiency, behavior, and clinical properties of superelastic NiTi versus multistranded stainless steel wires: a prospective clinical trial", Angle Orthod, 82, pp.915~921 (2012)[DOI]
  22. Maltagliati LA, "Transversal changes in dental arches from non-extraction treatment with self ligating brackets", Dental Press J Orthod, 18, pp.39~45 (2013)[DOI]
  23. Dalstra M, "Does the transition temperature of Cu-NiTi archwires affect the amount of tooth movement during alignment?", Orthod Craniofac Res, 7, pp.21~25 (2004)[DOI]
  24. Fleming PS, "Efficiency of mandibular arch alignment with 2 preadjusted edgewise appliances", Am J Orthod Dentofacial Orthop, 135, pp.597~602 (2009)[DOI]
  25. Burke SP, "A meta-analysis of mandibular intercanine width in treatment and postretention", Angle Orthod, 68, pp.53~60 (1998)
  26. Sadowsky C, "Long-term assessment of orthodontic relapse", Am J Orthod, 82, pp.456~463 (1982)[DOI]
  27. Franchi L, "Maxillary arch changes during leveling and aligning with fixed appliances and low-friction ligatures", Am J Orthod Dentofacial Orthop, 130, pp.88~91 (2006)[DOI]
  28. Almeida MR, "Dentoalveolar mandibular changes with self-ligating versus conventional bracket systems: a CBCT and dental cast study", Dental Press J Orthod, 20, pp.50~57 (2015)
  29. Lundstrom AF, "Malocclusion of the teeth regarded as a problem in connection with the apical base", Int J Orthod Oral Surg Radiogr, 11, pp.1022~1042 (1925)[DOI]
  30. Strang RHW, "The fallacy of denture expansion as a treatment procedure", Angle Orthod, 19, pp.12~22 (1949)

관련 논문AI추천

Effectiveness of laser-engineered copper-nickel titanium versus superelastic nickel-titanium aligning archwires: A randomized clinical trialAhmed Omar Khairullah, Kadhum Ammar Salim대한치과교정학회 · 대한치과교정학회지2024 · 제54권 제1호Effects of 3- and 6-weekly orthodontic activation protocols on the alignment of mandibular anterior teeth: A single-center randomized clinical trialAbdul Muqeet Chughtai, Maheen Ahmed, Mirza Ezaaf Shuja, Muhammad Aman, Waqar Jeelani대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제6호A prospective clinical trial to compare the performance of four initial orthodontic archwiresCarlos N. Elias, Catia C. A. Quintao, Daniel Koo, Luciane M. Menezes, Malcolm L. Jones대한치과교정학회 · 대한치과교정학회지2005 · 제35권 제5호En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding국윤아, 김성훈, 안효원, 정규림, Gerald Nelson, Jeong-Hyun Jee, Kyung-Won Seo대한치과교정학회 · 대한치과교정학회지2014 · 제44권 제5호Mandibular changes during initial alignment with SmartClip self-ligating and conventional brackets: A single-center prospective randomized controlled clinical trialDogan Kilkis, Mehmet Bayram, Metin Nur, Mevlut Celikoglu대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제2호Mandibular arch orthodontic treatment stability using passive self-ligating and conventional systems in adults: A randomized controlled trialMang Chek Wey, Norma Ab Rahman, Siti Adibah Othman대한치과교정학회 · 대한치과교정학회지2017 · 제47권 제1호

이 간행물의 다른 논문 (8건)