본문 바로가기
KERD
논문KCI 등재

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on conebeam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D CephTM program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D cephbiplanar), conventional radiography (3D cephconv), and CBCT (3D cephcbct). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland–Altman plotting. Results: There were no statistically significant differences between the 3D cephbiplanar and 3D cephcbct measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D cephcbct and 3D cephconv measurements. However, the values obtained from 3D cephconv showed larger deviations than those obtained from 3D cephbiplanar. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

Abstract

Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on conebeam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D CephTM program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D cephbiplanar), conventional radiography (3D cephconv), and CBCT (3D cephcbct). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland–Altman plotting. Results: There were no statistically significant differences between the 3D cephbiplanar and 3D cephcbct measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D cephcbct and 3D cephconv measurements. However, the values obtained from 3D cephconv showed larger deviations than those obtained from 3D cephbiplanar. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

참고문헌 (23)

  1. Bergersen EO, "Enlargement and distortion in cephalometric radiography: compensation tables for linear measurements", Angle Orthod, 50, pp.230~244 (1980)
  2. Ahlqvist J, "The cephalometric projection. Part II. Principles of image distortion in cephalography", Dentomaxillofac Radiol, 12, pp.101~108 (1983)[DOI]
  3. Pil-Kyo Jung, "Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements", 대한치과교정학회지, 45(6), pp.282~288 (2015), 대한치과교정학회
  4. Farman AG, "ALARA still applies", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 100, pp.395~397 (2005)[DOI]
  5. American Dental Association Council on Scientific Affairs, "The use of cone-beam computed tomography in dentistry: an advisory statement from the American Dental Association Council on Scientific Affairs", J Am Dent Assoc, 143, pp.899~902 (2012)[DOI]
  6. . Position statement by the American Academy of Oral and Maxillofacial Radiology, "Oral Surg Oral Med Oral Pathol Oral Radiol", 2013, 238~257, 10.1016[DOI]
  7. Abdelkarim AA, "Appropriate use of ionizing radiation in orthodontic practice and research", Am J Orthod Dentofacial Orthop, 147, pp.166~168 (2015)[DOI]
  8. Grayson B, "The three-dimensional cephalogram: Theory, techniques, and clinical application", Am J Orthod Dentofacial Orthop, 94, pp.327~337 (1988)[DOI]
  9. Brown T, "Computer-assisted location of reference points in three dimensions for radiographic cephalometry", Am J Orthod Dentofacial Orthop, 95, pp.490~498 (1989)[DOI]
  10. Trocme MC, "A biplanar cephalometric stereoradiography technique", Am J Orthod Dentofacial Orthop, 98, pp.168~175 (1990)[DOI]
  11. Bookstein FL, "Landmarks in three dimensions: reconstruction from cephalograms versus direct observation", Am J Orthod Dentofacial Orthop, 100, pp.133~140 (1991)[DOI]
  12. Kusnoto B, "Assessment of 3-dimensional computer-generated cephalometric measurements", Am J Orthod Dentofacial Orthop, 116, pp.390~399 (1999)[DOI]
  13. Mori Y, "An accurate three-dimensional cephalometric system: a solution for the correction of cephalic malpositioning", J Orthod, 28, pp.143~149 (2001)[DOI]
  14. Suh CH, "The fundamentals of computer aided X-ray analysis of the spine", J Biomech, 7, pp.161~169 (1974)[DOI]
  15. Selvik G, "Roentgen stereophotogrammetry for analysis of cranial growth", Am J Orthod, 89, pp.315~325 (1986)[DOI]
  16. Baumrind S, "Three-dimensional x-ray stereometry from paired coplanar images: A progress report", Am J Orthod Dentofacial Orthop, 84, pp.292~312 (1983)[DOI]
  17. Baumrind S, "The geometry of three-dimensional measurement from paired coplanar x-ray images", Am J Orthod, 84, pp.313~322 (1983)[DOI]
  18. Cutting C, "Three-dimensional computer-assisted design of craniofacial surgical procedures: optimization and interaction with cephalometric and CT-based models", Plast Reconstr Surg, 77, pp.877~887 (1986)[DOI]
  19. Selvik G, "Roentgen stereophotogrammetric analysis", Acta Radiol, 31, pp.113~126 (1990)[DOI]
  20. Bae GS, "The comparative study of three-dimensional cephalograms to actual models and conventional lateral cephalograma in linear and angular measurements", Korean J Orthod, 27, pp.129~140 (1997)
  21. Na ER, "Comparison of landmark identification errors between postero-anterior and antero-posterior cephalograms generated from cone-beam CT scan data", pp.2013
  22. Bland JM, "Statistical methods for assessing agreement between two methods of clinical measurement", Lancet, 327, pp.307~310 (1986)[DOI]
  23. Bland JM, "Measuring agreement in method comparison studies", Stat Methods Med Res, 8, pp.135~160 (1999)[DOI]

관련 논문AI추천

A comparative study of the reproducibility of landmark identification on posteroanterior and anteroposterior cephalograms generated from cone-beam computed tomography scansAL JAWAD HUSSEIN MUSTAFA SADIQ, Eui-Ri Na, Hyeon-Shik Hwang, Kyung-Min Lee대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제1호Cone beam computed tomography로 합성된 두부규격 방사선사진에서의 각 계측점의 정확도와 재현성에 관한 연구권대근, 민승기, 전인철, 팽준영대한구강악안면외과학회 · 대한구강악안면외과학회지2010 · 제36권 제2호악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석백종수, 송재철, 이희경영남대학교 의과대학 · Journal of Yeungnam Medical Science2001 · 제18권 제1호Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements문철현, Gung-Chol Lee, Pil-Kyo Jung대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제6호Use of Reference Ear Plug to improve accuracy of lateral cephalograms generated from cone-beam computed tomography scansGi-Soo Uhm, Hyeon-Shik Hwang, James A. McNamara, Jr, Jin-Hyoung Cho, Kyung-Min Lee대한치과교정학회 · 대한치과교정학회지2013 · 제43권 제2호Comparison of landmark position between conventional cephalometric radiography and CT scans projected to midsagittal plane김남국, 박재우, 장영일대한치과교정학회 · 대한치과교정학회지2008 · 제38권 제6호

이 간행물의 다른 논문 (8건)