본문 바로가기
KERD
논문KCI 등재

A comparative study of the reproducibility of landmark identification on posteroanterior and anteroposterior cephalograms generated from cone-beam computed tomography scans

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: This in-vivo study aimed to compare landmark identification errors in anteroposterior (AP) and posteroanterior (PA) cephalograms generated from conebeam computed tomography (CBCT) scan data in order to examine the feasibility of using AP cephalograms in clinical settings. Methods: AP and PA cephalograms were generated from CBCT scans obtained from 25 adults. Four experienced and four inexperienced examiners were selected depending on their experience levels in analyzing frontal cephalograms. They identified six cephalometric landmarks on AP and PA cephalograms. The errors incurred in positioning the cephalometric landmarks on the AP and PA cephalograms were calculated by using the straight-line distance and the horizontal and vertical components as parameters. Results: Comparison of the landmark identification errors in CBCT-generated frontal cephalograms revealed that landmark-dependent differences were greater than experienceor projection-dependent differences. Comparisons of landmark identification errors in the horizontal and vertical directions revealed larger errors in identification of the crista galli and anterior nasal spine in the vertical direction and the menton in the horizontal direction, in comparison with the other landmarks. Comparison of landmark identification errors between the AP and PA projections in CBCT-generated images revealed a slightly higher error rate in the AP projections, with no inter-examiner differences. Statistical testing of the differences in landmark identification errors between AP and PA cephalograms showed no statistically significant differences for all landmarks. Conclusions: The reproducibility of CBCT-generated AP cephalograms is comparable to that of PA cephalograms; therefore, AP cephalograms can be generated reliably from CBCT scan data in clinical settings.

Abstract

Objective: This in-vivo study aimed to compare landmark identification errors in anteroposterior (AP) and posteroanterior (PA) cephalograms generated from conebeam computed tomography (CBCT) scan data in order to examine the feasibility of using AP cephalograms in clinical settings. Methods: AP and PA cephalograms were generated from CBCT scans obtained from 25 adults. Four experienced and four inexperienced examiners were selected depending on their experience levels in analyzing frontal cephalograms. They identified six cephalometric landmarks on AP and PA cephalograms. The errors incurred in positioning the cephalometric landmarks on the AP and PA cephalograms were calculated by using the straight-line distance and the horizontal and vertical components as parameters. Results: Comparison of the landmark identification errors in CBCT-generated frontal cephalograms revealed that landmark-dependent differences were greater than experienceor projection-dependent differences. Comparisons of landmark identification errors in the horizontal and vertical directions revealed larger errors in identification of the crista galli and anterior nasal spine in the vertical direction and the menton in the horizontal direction, in comparison with the other landmarks. Comparison of landmark identification errors between the AP and PA projections in CBCT-generated images revealed a slightly higher error rate in the AP projections, with no inter-examiner differences. Statistical testing of the differences in landmark identification errors between AP and PA cephalograms showed no statistically significant differences for all landmarks. Conclusions: The reproducibility of CBCT-generated AP cephalograms is comparable to that of PA cephalograms; therefore, AP cephalograms can be generated reliably from CBCT scan data in clinical settings.

참고문헌 (22)

  1. Broadbent BH, "A new x-ray technique and its application of orthodontia", Angle Orthod, 1, pp.45~66 (1931)
  2. Mulick JF, "Clinical use of the frontal headfilm", Angle Orthod, 35, pp.299~304 (1965)
  3. Ricketts RM, "An overview of computerized cephalometrics", Am J Orthod, 61, pp.1~28 (1972)
  4. Grummons DC, "A frontal asymmetry analysis", J Clin Orthod, 21, pp.448~465 (1987)
  5. Whaites E., "X-ray equipment, films and processing", pp.35~40 (2002), Churchill Livingstone
  6. Mozzo P, "A new volumetric CT machine for dental imaging based on the cone-beam technique : preliminary results", Eur Radiol, 8, pp.1558~1564 (1998)
  7. Farman AG, "Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography", Am J Orthod Dentofacial Orthop, 130, pp.257~265 (2006)
  8. Moshiri M, "Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography", Am J Orthod Dentofacial Orthop, 132, pp.550~560 (2007)
  9. Kumar V, "In vivo comparison of conventional and cone beam CT synthesized cephalograms", Angle Orthod, 78, pp.873~879 (2008)
  10. Cevidanes L, "Head orientation in CBCT-generated cephalograms", Angle Orthod, 79, pp.971~977 (2009)
  11. van Vlijmen OJ, "A comparison of frontal radiographs obtained from cone beam CT scans and conventional frontal radiographs of human skulls", Int J Oral Maxillofac Surg, 38, pp.773~778 (2009)
  12. 선민규, "3차원 콘빔CT 영상에서 형성한 2차원 정모두부방사선사진영상의 정확도 증진을 위한 두부자세재현기의 효과", 대한치과교정학회지, 39(5), pp.289~299 (2009), 대한치과교정학회
  13. Hwang HS, "assignee. Ear plug for forming reference axis in CT taking. Korean Patent 10-0884354", ~ (2009)
  14. Kim EH, "The validity of head posture aligner in posteroanterior cephalometry", Korean J Orthod, 30, pp.543~552 (2000)
  15. Leonardi RM, "Accuracy of cephalometric landmarks on monitor-displayed radiographs with and without image emboss enhancement", Eur J Orthod, 32, pp.242~247 (2010)
  16. Proffit WR, "The search for truth: Diagnosis in surgical orthodontic treatment", pp.127~128 (1996), Mosby Year Book
  17. 고은희, "정모두부방사선사진 촬영시 두부의 수직회전에 따른 투사오차", 대한치과교정학회지, 33(2), pp.73~84 (2003), 대한치과교정학회
  18. El-Mangoury NH, "Landmark identification in computerized posteroanterior cephalometrics", Am J Orthod Dentofacial Orthop, 91, pp.57~61 (1987)
  19. Athanasiou AE, "Random errors in localization of landmarks in posteroanterior cephalograms", Br J Orthod, 26, pp.273~284 (1999)
  20. Eppley BL, "Computerized digital enhancement in craniofacial cephalometric radiography", J Oral Maxillofac Surg, 49, pp.1038~1043 (1991)
  21. Wiesemann RB, "Cephalometric landmark clarity in photostimulable phosphor images using pseudo-color and emboss enhancements", Int J CARS, 1, pp.105~112 (2006)
  22. Körner M, "Advances in digital radiography : physical principles and system overview", Radiographics, 27, pp.675~686 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (7건)