Objectives: The Korean Genome and Epidemiology Study (KoGES), a multicenter-based multi-cohort study, has collected information on body composition using two different bioelectrical impedence analysis (BIA) machines. The aim of the study was to evaluate the possibility of whether the test values measured from different BIA machines can be integrated through statistical adjustment algorithm under excellent inter-rater reliability. Methods: We selected two centers to measure inter-rater reliability of the two BIA machines. We set up the two machines side by side and measured subjects’ body compositions between October and December 2007. Duplicated test values of 848 subjects were collected. Pearson and intra-class correlation coefficients for inter-rater reliability were estimated using results from the two machines. To detect the feasibility for data integration, we constructed statistical compensation models using linear regression models with residual analysis and R-square values. Results: All correlation coefficients indicated excellent reliability except mineral mass. However, models using only duplicated body composition values for data integration were not feasible due to relatively low R2 values of 0.8 for mineral mass and target weight. To integrate body composition data, models adjusted for four empirical variables that were age,sex, weight and height were most ideal (all R2>0.9). Conclusions: The test values measured with the two BIA machines in the KoGES have excellent reliability for the nine body composition values. Based on reliability, values can be integrated through algorithmic statistical adjustment using regression equations that includes age, sex, weight, and height

Abstract

Objectives: The Korean Genome and Epidemiology Study (KoGES), a multicenter-based multi-cohort study, has collected information on body composition using two different bioelectrical impedence analysis (BIA) machines. The aim of the study was to evaluate the possibility of whether the test values measured from different BIA machines can be integrated through statistical adjustment algorithm under excellent inter-rater reliability. Methods: We selected two centers to measure inter-rater reliability of the two BIA machines. We set up the two machines side by side and measured subjects’ body compositions between October and December 2007. Duplicated test values of 848 subjects were collected. Pearson and intra-class correlation coefficients for inter-rater reliability were estimated using results from the two machines. To detect the feasibility for data integration, we constructed statistical compensation models using linear regression models with residual analysis and R-square values. Results: All correlation coefficients indicated excellent reliability except mineral mass. However, models using only duplicated body composition values for data integration were not feasible due to relatively low R2 values of 0.8 for mineral mass and target weight. To integrate body composition data, models adjusted for four empirical variables that were age,sex, weight and height were most ideal (all R2>0.9). Conclusions: The test values measured with the two BIA machines in the KoGES have excellent reliability for the nine body composition values. Based on reliability, values can be integrated through algorithmic statistical adjustment using regression equations that includes age, sex, weight, and height

참고문헌 (10)

  1. "National Institute of Health, KCDC. Korean Genome and Epidemiology Study (KoGES)"[URL]
  2. Yoo KY, "Genomic epidemiology cohorts in Korea: present and the future", Asian Pac J Cancer Prev, 6(3), pp.238~243 (2005)
  3. Gassman JJ, "Data quality assurance, monitoring, and reporting", Control Clin Trials, 16(2), pp.104S~136S (1995)
  4. The Korean Society for Preventive Medicine, "Preventive Medicine and Public Health", pp.83~86 (2010), Gyechuk-Munhwasa
  5. Ahn YO, "Manual for Medical Statistics", pp.105~113 (2005), Seoul National University Press
  6. Altman DG, "Practical Statistics for Medical Research", pp.409~419 (1992), Chapman & Hall
  7. Dehghan M, "bioelectrical impedance accurate for use in large epidemiological studies?", Nutr J, 7, pp.26~ (2008)
  8. Biau DJ, "Provider and center effect in multicenter randomized controlled trials of surgical specialties: an analysis on patient-level data", Ann Surg, 247(5), pp.892~898 (2008)
  9. Gordis L, "Epidemiology, 3rd ed", pp.87~88 (2004), Elsevier Saunders
  10. Bangdiwala SI, "Coordination of international multicenter studies: governance and administrative structure", Salud Publica Mex, 45(1), pp.58~66 (2003)

관련 논문AI추천

External cross-validation of bioelectrical impedance analysis for the assessment of body composition in Korean adults김찬, 김동원, 김철현, 김혜진, 민선식, 박미라, 박혜순, 이재용, 정소정, 한승호한국영양학회 · Nutrition Research and Practice2011 · 제5권 제3호Evaluating the Accuracy and Clinical Utility of Bioelectrical Impedance Analysis (BIA) Devices for Body Composition Measurements in Clinical Practice: Comparison of Four Types of BIA Equipment and Dual-Energy X-ray Absorptiometry배성환, 선화연, 손주연, 유병욱, 이소연대한임상건강증진학회 · Korean Journal of Health Promotion2025 · 제25권 제2호The Association between Muscle Mass Deficits Estimated from Bioelectrical Impedance Analysis and Lumbar Spine Bone Mineral Density in Korean Adults김희진, 이계봉, 임인재, 장혜연, 최희정, Sul-Bit Cho대한골대사학회 · 대한골대사학회지2016 · 제23권 제2호Need for Cross-calibration of Body Composition Even with the Same Model of Dual-energy X-ray Absorptiometry정윤석, Byung Joo Lee, So-Yeon An, Yong Jun Choi대한골다공증학회 · OSTEOPOROSIS2012 · 제10권 제3호생체전기저항법과 인체측정법에 의한 남자빙상선수의 체지방률 추정김윤만, 김철현, 김혜진한국체육측정평가학회 · 한국체육측정평가학회지2005 · 제7권 제1호Comparison of Validity and Accuracy of Circumference, SKF, and BIA Method in Predicting % Body FatCho Chang-mo동북아학술저널연합 · Kinesiology2019 · 제4권 제2호

이 간행물의 다른 논문 (10건)