Objective: In our previous study, glass-fiber-reinforced plastics (GFRPs) made from polycarbonate and glass fibers were prepared for esthetic orthodontic wires using pultrusion. These laboratory GFRP wires are more transparent than the commercially available nickel-titanium wire; however, an investigation of the color stability of GFRP during orthodontic treatment is needed. Accordingly, in the present study, the color stability of GFRP was assessed using colorimetry. Methods: Preparation of GFRP esthetic round wires (diameter: 0.45 mm [0.018 inch]) using pultrusion was described previously. Here, to investigate how the diameter of fiber reinforcement affects color stability, GFRPs were prepared by incorporating either 13-mm (GFRP-13) or 7-mm glass (GFRP-7) fibers. The color changes of GFRPs after 24 h, and following 1, 2, and 4 weeks of coffee immersion at 37oC, were measured by colorimetry. We evaluated the color stability of GFRPs by two evaluating units: the color difference (ΔE*) and National Bureau of Standards (NBS). Results: After immersion, both GFRPs showed almost no visible color change. According to the colorimetry measurements, the ΔE* values of GFRP-13 and GFRP-7 were 0.73−1.16, and 0.62−1.10, respectively. In accordance with NBS units, both GFRPs showed “slight” color changes. As a result, there were no significant differences in the ΔE* values or NBS units for GFRP-13 or GFRP-7. Moreover, for both GFRPs, no significant differences were observed in any of the immersion periods. Conclusions: Our findings suggest that the GFRPs will maintain high color stability during orthodontic treatment, and are an attractive prospect as esthetic orthodontic wires. [Korean J Orthod 2015;45(3):130-135]
Abstract
Objective: In our previous study, glass-fiber-reinforced plastics (GFRPs) made from polycarbonate and glass fibers were prepared for esthetic orthodontic wires using pultrusion. These laboratory GFRP wires are more transparent than the commercially available nickel-titanium wire; however, an investigation of the color stability of GFRP during orthodontic treatment is needed. Accordingly, in the present study, the color stability of GFRP was assessed using colorimetry. Methods: Preparation of GFRP esthetic round wires (diameter: 0.45 mm [0.018 inch]) using pultrusion was described previously. Here, to investigate how the diameter of fiber reinforcement affects color stability, GFRPs were prepared by incorporating either 13-mm (GFRP-13) or 7-mm glass (GFRP-7) fibers. The color changes of GFRPs after 24 h, and following 1, 2, and 4 weeks of coffee immersion at 37oC, were measured by colorimetry. We evaluated the color stability of GFRPs by two evaluating units: the color difference (ΔE*) and National Bureau of Standards (NBS). Results: After immersion, both GFRPs showed almost no visible color change. According to the colorimetry measurements, the ΔE* values of GFRP-13 and GFRP-7 were 0.73−1.16, and 0.62−1.10, respectively. In accordance with NBS units, both GFRPs showed “slight” color changes. As a result, there were no significant differences in the ΔE* values or NBS units for GFRP-13 or GFRP-7. Moreover, for both GFRPs, no significant differences were observed in any of the immersion periods. Conclusions: Our findings suggest that the GFRPs will maintain high color stability during orthodontic treatment, and are an attractive prospect as esthetic orthodontic wires. [Korean J Orthod 2015;45(3):130-135]
참고문헌 (28)
- O’Brien WJ., "Dental materials and their selection" (2008), Quintessence Pub Co
- Eliades T., "Orthodontics:current principles and techniques", pp.2012, Elsevier
- Elayyan F, "Ex vivo surface and mechanical properties of coated orthodontic archwires", Eur J Orthod, 30, pp.661~667 (2008)
- Yu B, "Aesthetic colour performance of plastic and ceramic brackets-an in vitro study", J Orthod, 38, pp.167~174 (2011)
- Lee YK., "Colour and translucency of tooth-coloured orthodontic brackets.", Eur J Orthod, 30, pp.205~210 (2008)
- Eliades T, "Orthodontic materials", pp.143~172 (2001), Thieme
- da Silva DL, "Coating stability and surface characteristics of esthetic orthodontic coated archwires", Angle Orthod, 83, pp.994~1001 (2013)
- Zegan G, "Surface characteristics of retrieved coated and nickel-titanium orthodontic archwires", Rom J Morphol Embryol, 53, pp.935~939 (2012)
- Fujihara K, "Fibrous composite materials in dentistry and orthopaedics: Review and applications", Compos Sci Technol, 64, pp.775~788 (2004)
- Tanimoto Y, "Preparation, mechanical, and in vitro properties of glass fiber-reinforced polycarbonate composites for orthodontic application", J Biomed Mater Res B Appl Biomater (2014)[DOI]
- de Mendonca MR, "Spectrophotometric evaluation of color changes of esthetic brackets stored in potentially staining solutions", RPG Rev pós-grad, 18, pp.20~27 (2011)
- Filho HL, "Colour stability of aesthetic brackets: ceramic and plastic", Aust Orthod J, 29, pp.13~20 (2013)
- Faltermeier A, "In vitro colour stability of aesthetic brackets", Eur J Orthod, 29, pp.354~358 (2007)
- Martins da Silva AV, "In vivo color changes of esthetic orthodontic ligatures", Dental Press J Orthod, 17, pp.76~80 (2012)
- Kim SH, "Measurement of discolouration of orthodontic elastomeric modules with a digital camera", Eur J Orthod, 31, pp.556~562 (2009)
- da Silva DL, "Color stability and fluorescence of different orthodontic esthetic archwires", Angle Orthod, 83, pp.127~132 (2013)
- Lee YK., "Changes in the reflected and transmitted color of esthetic brackets after thermal cycling", Am J Orthod Dentofacial Orthop, 133, pp.641~ (2008)
- Yamanel K, "Assessment of color parameters of composite resin shade guides using digital imaging versus colorimeter", J Esthet Restor Dent, 22, pp.379~388 (2010)
- Joiner A, "Tooth colour : a review of the literature", J Dent, 32(Suppl 1), pp.3~12 (2004)
- Faltermeier J, "The influence of electron beam irradiation on colour stability and hardness of aesthetic brackets", Eur J Orthod, 34, pp.427~431 (2012)
- Douglas RD, "Intraoral determination of the tolerance of dentists for perceptibility and acceptability of shade mismatch", J Prosthet Dent, 97, pp.200~208 (2007)
- Scabell AL, "Failure of fiber reinforced composite archwires", J Res Practice Dent (2013)[DOI]
- Hamanaka I, "Influence of water sorption on mechanical properties of injection-molded thermoplastic denture base resins", Acta Odontol Scand, 72, pp.859~865 (2014)
- Ardeshna AP, "Clinical evaluation of fiber-reinforcedplastic bonded orthodontic retainers", Am J Orthod Dentofacial Orthop, 139, pp.761~767 (2011)
- Shiozawa M, "Color stability of adhesive resin cements after immersion in coffee", Clin Oral Investig (2014)[DOI]
- Dietschi D, "Comparison of the color stability of ten new-generation composites: an in vitro study", Dent Mater, 10, pp.353~362 (1994)
- Lee IB, "Slumping tendency and rheological properties of flowable composites", Dent Mater, 26, pp.443~448 (2010)
- Ertaş E, "Color stability of resin composites after immersion in different drinks", Dent Mater J, 25 (2006)