Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor
1
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Objective: The purposes of this study were to measure the orthodontic forcesgenerated by thermoplastic aligners and investigate the possible influences ofdifferent activations for lingual bodily movements on orthodontic forces, andtheir attenuation. Methods: Thermoplastic material of 1.0-mm in thickness wasused to manufacture aligners for 0.2, 0.3, 0.4, 0.5, and 0.6 mm activations forlingual bodily movements of the maxillary central incisor. The orthodontic forcein the lingual direction delivered by the thermoplastic aligners was measuredusing a micro-stress sensor system for the invisible orthodontic technique,and was monitored for 2 weeks. Results: Orthodontic force increased with theamount of activation of the aligner in the initial measurements. The attenuationspeed in the 0.6 mm group was faster than that of the other groups (p < 0.05). All aligners demonstrated rapid relaxation in the first 8 hours, which thendecreased slowly and plateaued on day 4 or 5. Conclusions: The amount ofactivation had a substantial influence on the orthodontic force imparted by thealigners. The results suggest that the activation of lingual bodily movement ofthe maxillary central incisor should not exceed 0.5 mm. The initial 4 or 5 days isimportant with respect to orthodontic treatment incorporating an aligner. [Korean J Orthod 2016;46(2):65-72]
Abstract
Objective: The purposes of this study were to measure the orthodontic forcesgenerated by thermoplastic aligners and investigate the possible influences ofdifferent activations for lingual bodily movements on orthodontic forces, andtheir attenuation. Methods: Thermoplastic material of 1.0-mm in thickness wasused to manufacture aligners for 0.2, 0.3, 0.4, 0.5, and 0.6 mm activations forlingual bodily movements of the maxillary central incisor. The orthodontic forcein the lingual direction delivered by the thermoplastic aligners was measuredusing a micro-stress sensor system for the invisible orthodontic technique,and was monitored for 2 weeks. Results: Orthodontic force increased with theamount of activation of the aligner in the initial measurements. The attenuationspeed in the 0.6 mm group was faster than that of the other groups (p < 0.05). All aligners demonstrated rapid relaxation in the first 8 hours, which thendecreased slowly and plateaued on day 4 or 5. Conclusions: The amount ofactivation had a substantial influence on the orthodontic force imparted by thealigners. The results suggest that the activation of lingual bodily movement ofthe maxillary central incisor should not exceed 0.5 mm. The initial 4 or 5 days isimportant with respect to orthodontic treatment incorporating an aligner. [Korean J Orthod 2016;46(2):65-72]
참고문헌 (28)
- Rosvall MD, "Attractiveness, acceptability, and value of orthodontic appliances", Am J Orthod Dentofacial Orthop, 135, pp.276.e1~276.e12 (2009)
- Fujiyama K, "Analysis of pain level in cases treated with Invisalign aligner: comparison with fixed edgewise appliance therapy", Prog Orthod, 15, pp.64~ (2014)
- Schaefer I, "Halitosis, oral health and quality of life during treatment with Invisalign(®)and the effect of a low-dose chlorhexidine solution", J Orofac Orthop, 71, pp.430~441 (2010)
- Harnick DJ, "Using clear aligner therapy to correct malocclusion with crowding and an open bite", Gen Dent, 60, pp.218~223 (2012)
- Frongia G, "Correction of severe tooth rotations using clear aligners: a case report", Aust Orthod J, 28, pp.245~249 (2012)
- Giancotti A, "A miniscrew-supported intrusion auxiliary for openbite treatment with Invisalign", J Clin Orthod, 48, pp.348~358 (2014)
- Kassas W, "Assessment of invisalign treatment outcomes using the ABO model grading system", J World Fed Orthod, 2, pp.e61~e64 (2013)
- Casko JS, "Objective grading system for dental casts and panoramic radiographs. American Board of Orthodontics", Am J Orthod Dentofacial Orthop, 114, pp.589~599 (1998)
- Rossini G, "Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review", Angle Orthod, 85, pp.881~889 (2015)
- Sheridan JJ, "The readers' corner. 2. What percentage of your patients are being treated with Invisalign appliances?", J Clin Orthod, 38, pp.544~545 (2004)
- Kohda N, "Effects of mechanical properties of thermoplastic materials on the initial force of thermoplastic appliances", Angle Orthod, 83, pp.476~483 (2013)
- Fang D, "Dynamic stress relaxation of orthodontic thermoplastic materials in a simulated oral environment", Dent Mater J, 32, pp.946~951 (2013)
- Rues S, "An analysis of the measurement principle of smart brackets for 3D force and moment monitoring in orthodontics", J Biomech, 44, pp.1892~1900 (2011)
- Hahn W, "Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping", Am J Orthod Dentofacial Orthop, 136, pp.12.e1~12.e7 (2009)
- Hahn W, "Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor", Angle Orthod, 80, pp.239~246 (2010)
- Hahn W, "Initial forces generated by three types of thermoplastic appliances on an upper central incisor during tipping", Eur J Orthod, 31, pp.625~631 (2009)
- Ren CC, "Establishment of the micro-stress sensor measurement system for invisible aligner technique", Zhonghua Kou Qiang Yi Xue Za Zhi, 46, pp.600~603 (2011)
- Tian K, "Design, fabrication, and calibration of a piezoresistive stress sensor on SOI wafers for electronic packaging applications", IEEE Trans Comp Packag Tech, 32, pp.513~520 (2009)
- Shi Y, "An ultra-thin piezoresistive stress sensor for measurement of tooth orthodontic force in Invisible aligners", IEEE Sensors J, 12, pp.1090~1097 (2012)
- Lapatki BG, "Smart bracket for multi-dimensional force and moment measurement", J Dent Res, 86, pp.73~78 (2007)
- Lapatki BG, "Smart brackets for 3D-forcemoment measurements in orthodontic research and therapy-developmental status and prospects", J Orofac Orthop, 68, pp.377~396 (2007)
- Boyd RL, "The Invisalign system in adult orthodontics: mild crowding and space closure case", J Clin Orthod, 34, pp.203~212 (2000)
- Sheridan JJ, "Essix appliance:minor tooth movement with divots and windows", J Clin Orthod, 28, pp.659~663 (1994)
- Barbagallo LJ, "A novel pressure film approach for determining the force imparted by clear removable thermoplastic appliances", Ann Biomed Eng, 36, pp.335~341 (2008)
- Proffit WR, "Contemporary orthodontics", pp.341~358 (2000), Mosby
- Kusy RP, "Orthodontic biomaterials: from the past to the present", Angle Orthod, 72, pp.501~512 (2002)
- Eliades T, "Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance", Am J Orthod Dentofacial Orthop, 127, pp.403~412 (2005)
- Ralph WJ, "Tensile behaviour of the periodontal ligament", J Periodontal Res, 17, pp.423~426 (1982)
