Prediction of optimal bending angles of a running loop to achieve bodily protraction of a molar using the finite element method
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objective: The purpose of this study was to predict the optimal bending angles of a running loop for bodily protraction of the mandibular first molars and to clarify the mechanics of molar tipping and rotation. Methods: A three-dimensional finite element model was developed for predicting tooth movement, and a mechanical model based on the beam theory was constructed for clarifying force systems. Results: When a running loop without bends was used, the molar tipped mesially by 9.6o and rotated counterclockwise by 5.4o. These angles were almost similar to those predicted by the beam theory. When the amount of tip-back and toe-in angles were 11.5o and 9.9o, respectively, bodily movement of the molar was achieved. When the bend angles were increased to 14.2o and 18.7o, the molar tipped distally by 4.9o and rotated clockwise by 1.5o. Conclusions: Bodily movement of a mandibular first molar was achieved during protraction by controlling the tip-back and toe-in angles with the use of a running loop. The beam theory was effective for understanding the mechanics of molar tipping and rotation, as well as for predicting the optimal bending angles.[Korean J Orthod 2018;48(1):3-10]
Abstract
Objective: The purpose of this study was to predict the optimal bending angles of a running loop for bodily protraction of the mandibular first molars and to clarify the mechanics of molar tipping and rotation. Methods: A three-dimensional finite element model was developed for predicting tooth movement, and a mechanical model based on the beam theory was constructed for clarifying force systems. Results: When a running loop without bends was used, the molar tipped mesially by 9.6o and rotated counterclockwise by 5.4o. These angles were almost similar to those predicted by the beam theory. When the amount of tip-back and toe-in angles were 11.5o and 9.9o, respectively, bodily movement of the molar was achieved. When the bend angles were increased to 14.2o and 18.7o, the molar tipped distally by 4.9o and rotated clockwise by 1.5o. Conclusions: Bodily movement of a mandibular first molar was achieved during protraction by controlling the tip-back and toe-in angles with the use of a running loop. The beam theory was effective for understanding the mechanics of molar tipping and rotation, as well as for predicting the optimal bending angles.[Korean J Orthod 2018;48(1):3-10]
참고문헌 (18)
- Proffit WR, "Forty-year review of extraction frequencies at a university orthodontic clinic", Angle Orthod, 64, pp.407~414 (1994)
- Schoppe RJ, "An Analysis of second premolar extraction procedures", Angle Orthod, 34, pp.292~302 (1964)
- Brandt S, "Different extractions for different malocclusions", Am J Orthod, 68, pp.15~41 (1975)[DOI]
- Na JY, "Orthodontic treatment with upper first and lower second premolars extracted", Korean J Orthod, 26, pp.113~124 (1996)
- Schumacher HA, "Analysis of forces and moments in arch guided molar protraction using Class I and Class II elastics. An invitro study", J Orofac Orthop, 57, pp.4~14 (1996)[DOI]
- Romeo DA, "Tip-back mechanics", Am J Orthod, 72, pp.414~421 (1977)[DOI]
- Kusy RP, "Influence of force systems on archwirebracket combinations", Am J Orthod Dentofacial Orthop, 127, pp.333~342 (2005)[DOI]
- Siatkowski RE, "Force system analysis of V-bend sliding mechanics", J Clin Orthod, 28, pp.539~546 (1994)
- Chae J, "Running loop in unusual molar extraction treatment", Am J Orthod Dentofacial Orthop, 132, pp.528~539 (2007)[DOI]
- Technique clinic, "The shoehorn technique", J Clin Orthod, 4, pp.228~229 (1970)
- Peretta R, "Cherry loop: a new loop to move the mandibular molar mesially", Prog Orthod, 2, pp.24~29 (2001)[DOI]
- Kojima Y, "Finite element analysis of the effect of force directions on tooth movement in extraction space closure with miniscrew sliding mechanics", Am J Orthod Dentofacial Orthop, 142, pp.501~508 (2012)[DOI]
- Kojima Y, "Numerical simulations of canine retraction with T-loop springs based on the updated moment-to-force ratio", Eur J Orthod, 34, pp.10~18 (2012)[DOI]
- Sun-Mi Cho, "The effects of alveolar bone loss and miniscrew position on initial tooth displacement during intrusion of the maxillary anterior teeth: Finite element analysis", 대한치과교정학회지, 46(5), pp.310~322 (2016), 대한치과교정학회
- Kusy RP, "Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states", Angle Orthod, 61, pp.293~302 (1991)
- Timoshenko SP, "Element of strength of materials" (1968), Van Nostrand Maruzen
- Soenen PL, "Initial tooth displacement in vivo as a predictor of long-term displacement", Eur J Orthod, 21, pp.405~411 (1999)[DOI]
- Muhlemann HR, "10 years of tooth-mobility measurements", J Periodont, 31, pp.110~122 (1960)[DOI]
