Comparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (singlewire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional–scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the singlewire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.
Abstract
Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (singlewire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional–scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the singlewire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.
참고문헌 (17)
- Lim SM, "The Tandem Archwire technique in lingual orthodontic", J Clin Orthod, 47, pp.232~240 (2013)
- Lombardo L, "3D FEM comparison of lingual and labial orthodontics in en masse retraction", Prog Orthod, 15, pp.38~ (2014)
- Hong RK, "Lever-arm and miniimplant system for anterior torque control during retraction in lingual orthodontic treatment", Angle Orthod, 75, pp.129~141 (2005)
- Hong RK, "Update on the Fujita lingual bracket", J Clin Orthod, 33, pp.136~142 (1999)
- Beckwith FR, "An evaluation of factors affecting duration of orthodontic treatment", Am J Orthod Dentofacial Orthop, 115, pp.439~447 (1999)
- Meikle MC, "Guest editorial : what do prospective randomized clinical trials tell us about the treatment of class II malocclusions? A personal viewpoint", Eur J Orthod, 27, pp.105~114 (2005)
- Liang W, "Torque control of the maxillary incisors in lingual and labial orthodontics : a 3-dimensional finite element analysis", Am J Orthod Dentofacial Orthop, 135, pp.316~322 (2009)
- Rhee JN, "A comparison between friction and frictionless mechanics with a new typodont simulation system", Am J Orthod Dentofacial Orthop, 119, pp.292~299 (2001)
- Kyung HM, "Heat Induction Typodont System®(HITS)for simulating orthodontic tooth movement", Clin J Korean Assoc Orthod, 3, pp.177~179 (2013)
- 김지영, "Effects of bracket slot size during en-masse retraction of the six maxillary anterior teeth using an induction-heating typodont simulation system", 대한치과교정학회지, 47(3), pp.158~166 (2017), 대한치과교정학회
- Kyung HM, "The lingual plain-wire system with micro-implant anchorage", J Clin Orthod, 38, pp.388~395 (2004)
- Kim T, "New indirect bonding method for lingual orthodontics", J Clin Orthod, 34, pp.348~350 (2000)
- Lee JS, "Micro-implant anchorage for lingual treatment of a skeletal class II malocclusion", J Clin Orthod, 35, pp.643~647 (2001)
- Isaacson RJ, "Moments with the edgewise appliance : incisor torque control", Am J Orthod Dentofacial Orthop, 103, pp.428~438 (1993)
- Sifakakis I, "A comparative assessment of torque generated by lingual and conventional brackets", Eur J Orthod, 35, pp.375~380 (2013)
- Jang HJ, "Locating the center of resistance of maxillary anterior teeth retracted by Double J Retractor with palatal miniscrews", Angle Orthod, 80, pp.1023~1028 (2010)
- 김경희, "Lingual sliding mechanics의 lever arm 효과에 대한 유한요소분석", 대한치과교정학회지, 41(5), pp.324~336 (2011), 대한치과교정학회