Quantitative cone-beam computed tomography evaluation of hard and soft tissue thicknesses in the midpalatal suture region to facilitate orthodontic mini-implant placement
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objective: To identify the most favorable sites that optimize the initial stability and survival rate of orthodontic mini-implants, this study measured hard and soft tissue thicknesses in the median and paramedian regions of the palate using cone-beam computed tomography (CBCT) and determined possible sexand age-related differences in these thicknesses. Methods: The study sample comprised CBCT images of 189 healthy subjects. The sample was divided into four groups according to age. A grid area was set for the measurement of hard and soft tissue thicknesses in the palate. Vertical lines were marked at intervals of 0, 1.5, and 3.0 mm lateral to the midpalatal suture, while horizontal lines were marked at 2-mm intervals up to 24 mm from the posterior margin of the incisive foramen. Measurements were made at 65 points of intersection between the horizontal and vertical lines. Results: The palatal hard tissue thickness decreased from the anterior to the posterior region, with a decrease in the medial-to-lateral direction in the middle and posterior regions. While the soft tissue was rather thick around the lateral aspects of the palatal arch, it formed a constant layer that was only 1–2-mm thick throughout the palate. Statistically significant differences were observed according to sex and age. Conclusions: The anterolateral palate as well as the midpalatal suture seem to be the most favorable sites for insertion of orthodontic mini-implants. The thickness of the palate differed by age and sex; these differences should be considered while planning the placement of orthodontic mini-implants.
Abstract
Objective: To identify the most favorable sites that optimize the initial stability and survival rate of orthodontic mini-implants, this study measured hard and soft tissue thicknesses in the median and paramedian regions of the palate using cone-beam computed tomography (CBCT) and determined possible sexand age-related differences in these thicknesses. Methods: The study sample comprised CBCT images of 189 healthy subjects. The sample was divided into four groups according to age. A grid area was set for the measurement of hard and soft tissue thicknesses in the palate. Vertical lines were marked at intervals of 0, 1.5, and 3.0 mm lateral to the midpalatal suture, while horizontal lines were marked at 2-mm intervals up to 24 mm from the posterior margin of the incisive foramen. Measurements were made at 65 points of intersection between the horizontal and vertical lines. Results: The palatal hard tissue thickness decreased from the anterior to the posterior region, with a decrease in the medial-to-lateral direction in the middle and posterior regions. While the soft tissue was rather thick around the lateral aspects of the palatal arch, it formed a constant layer that was only 1–2-mm thick throughout the palate. Statistically significant differences were observed according to sex and age. Conclusions: The anterolateral palate as well as the midpalatal suture seem to be the most favorable sites for insertion of orthodontic mini-implants. The thickness of the palate differed by age and sex; these differences should be considered while planning the placement of orthodontic mini-implants.
참고문헌 (25)
- Janssen KI, "Skeletal anchorage in orthodontics--a review of various systems in animal and human studies", Int J Oral Maxillofac Implants, 23, pp.75~88 (2008)
- Seo YJ, "Camouflage treatment of skeletal class III malocclusion with asymmetry using a bone-borne rapid maxillary expander", Angle Orthod, 85, pp.322~334 (2015)
- Lee KJ, "Miniscrew-assisted nonsurgical palatal expansion before orthognathic surgery for a patient with severe mandibular prognathism", Am J Orthod Dentofacial Orthop, 137, pp.830~839 (2010)
- Celenk-Koca T, "Evaluation of miniscrew-supported rapid maxillary expansion in adolescents : a prospective randomized clinical trial", Angle Orthod, 88, pp.702~709 (2018)
- 경승현, "미니스크류 식립 부위로서 정중 구개봉합부 골의 두께에 관한 연구", 대한치과교정학회지, 34(1), pp.63~70 (2004), 대한치과교정학회
- Kim HJ, "Softtissue and cortical-bone thickness at orthodontic implant sites", Am J Orthod Dentofacial Orthop, 130, pp.177~182 (2006)
- Keles A, "Bodily distalization of molars with absolute anchorage", Angle Orthod, 73, pp.471~482 (2003)
- Poorsattar-Bejeh Mir A, "Individual scoring and mapping of hard and soft tissues of the anterior hard palate for orthodontic miniscrew insertion", J Investig Clin Dent, 8, pp.e12186~ (2017)
- Lyu X, "Assessment of available sites for palatal orthodontic mini-implants through cone-beam computed tomography", Angle Orthod, 90, pp.516~523 (2020)
- Bjöerk A, "A method for epidemiological registration of malocclusion", Acta Odontol Scand, 22, pp.27~41 (1964)
- Kang S, "Bone thickness of the palate for orthodontic mini-implant anchorage in adults", Am J Orthod Dentofacial Orthop, 131(4 Suppl), pp.S74~81 (2007)
- Ryu JH, "Palatal bone thickness compared with cone-beam computed tomography in adolescents and adults for mini-implant placement", Am J Orthod Dentofacial Orthop, 142, pp.207~212 (2012)
- Schoenwolf GC, "Larsen's human embryology" (2015), Churchill Livingstone
- Chhatwani S, "Three-dimensional quantitative assessment of palatal bone height for insertion of orthodontic implants-a retrospective CBCT study", Head Face Med, 15, pp.9~ (2019)
- Wehrbein H, "The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem", Clin Oral Implants Res, 7, pp.410~416 (1996)
- Wehrbein H, "Palatal bone support for orthodontic implant anchorage--a clinical and radiological study", Eur J Orthod, 21, pp.65~70 (1999)
- Bernhart T, "Short epithetic implants for orthodontic anchorage in the paramedian region of the palate. A clinical study", Clin Oral Implants Res, 12, pp.624~631 (2001)
- Choi SH, "Nonsurgical miniscrew-assisted rapid maxillary expansion results in acceptable stability in young adults", Angle Orthod, 86, pp.713~720 (2016)
- Yadav S, "Gender and growth variation in palatal bone thickness and density for miniimplant placement", Prog Orthod, 19, pp.43~ (2018)
- Cassetta M, "Evaluation of alveolar cortical bone thickness and density for orthodontic mini-implant placement", J Clin Exp Dent, 5, pp.e245~52 (2013)
- Chen YJ, "Stability of miniplates and miniscrews used for orthodontic anchorage : experience with 492 temporary anchorage devices", Clin Oral Implants Res, 19, pp.1188~1196 (2008)
- Yao CC, "Revisiting the stability of mini-implants used for orthodontic anchorage", J Formos Med Assoc, 114, pp.1122~1128 (2015)
- Baumgaertel S, "Hard and soft tissue considerations at mini-implant insertion sites", J Orthod, 41Suppl 1, pp.S3~7 (2014)
- Kim JS, "Analysis of lingual en masse retraction combining a C-lingual retractor and a palatal plate", Angle Orthod, 81, pp.662~669 (2011)
- 김연태, "Three-dimensional observations of the incisive foramen on cone-beam computed tomography image analysis", Journal of Periodontal & Implant Science, 50(1), pp.48~55 (2020), 대한치주과학회[DOI]
