본문 바로가기
KERD
논문KCI 등재

Combined anterior and posterior miniscrews increase apical root resorption of maxillary incisors in protrusion and premolar extraction cases

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: Miniscrews are commonly utilized as temporary anchorage devices (TADs) in cases of maxillary protrusion and premolar extraction. This study aimed to investigate the effects and potential side effects of two conventional miniscrew configurations on the maxillary incisors. Methods: Eighty-two adult patients with maxillary dentoalveolar protrusion who had undergone bilateral first premolar extraction were retrospectively divided into three groups: non-TAD, two posterior miniscrews only (P-TADs), and two anterior and two posterior miniscrews combined (AP-TADs). Cone-beam computed tomography was used to evaluate the maxillary central incisors (U1). Results: The APTADs group had significantly greater U1 intrusion (1.99 ± 2.37 mm, n = 50) and less retroclination (1.70° ± 8.80°) compared to the P-TADs (–0.07 ± 1.65 mm and 9.45° ± 10.68°, n = 60) and non-TAD group (0.30 ± 1.61 mm and 1.91° ± 9.39°, n = 54). However, the AP-TADs group suffered from significantly greater apical root resorption (ARR) of U1 (2.69 ± 1.38 mm) than the P-TADs (1.63 ± 1.46 mm) and non-TAD group (0.89 ± 0.97 mm). Notably, the incidence of grade IV ARR was 16.6% in the AP-TADs group, significantly higher than the rates observed in the P-TADs (6.7%) and non-TAD (1.9%) groups. Multiple regression analysis revealed that after excluding tooth movement factors, the AP-TADs configuration resulted in an additional 0.5 mm of ARR compared with the P-TADs group. Conclusions: In cases of maxillary protrusion and premolar extraction, the use of combined anterior and posterior miniscrews enhances incisor intrusion and minimizes torque loss of the maxillary incisors. However, this approach results in more severe ARR, likely due to the increased apical movement and composite force exerted.

Abstract

Objective: Miniscrews are commonly utilized as temporary anchorage devices (TADs) in cases of maxillary protrusion and premolar extraction. This study aimed to investigate the effects and potential side effects of two conventional miniscrew configurations on the maxillary incisors. Methods: Eighty-two adult patients with maxillary dentoalveolar protrusion who had undergone bilateral first premolar extraction were retrospectively divided into three groups: non-TAD, two posterior miniscrews only (P-TADs), and two anterior and two posterior miniscrews combined (AP-TADs). Cone-beam computed tomography was used to evaluate the maxillary central incisors (U1). Results: The APTADs group had significantly greater U1 intrusion (1.99 ± 2.37 mm, n = 50) and less retroclination (1.70° ± 8.80°) compared to the P-TADs (–0.07 ± 1.65 mm and 9.45° ± 10.68°, n = 60) and non-TAD group (0.30 ± 1.61 mm and 1.91° ± 9.39°, n = 54). However, the AP-TADs group suffered from significantly greater apical root resorption (ARR) of U1 (2.69 ± 1.38 mm) than the P-TADs (1.63 ± 1.46 mm) and non-TAD group (0.89 ± 0.97 mm). Notably, the incidence of grade IV ARR was 16.6% in the AP-TADs group, significantly higher than the rates observed in the P-TADs (6.7%) and non-TAD (1.9%) groups. Multiple regression analysis revealed that after excluding tooth movement factors, the AP-TADs configuration resulted in an additional 0.5 mm of ARR compared with the P-TADs group. Conclusions: In cases of maxillary protrusion and premolar extraction, the use of combined anterior and posterior miniscrews enhances incisor intrusion and minimizes torque loss of the maxillary incisors. However, this approach results in more severe ARR, likely due to the increased apical movement and composite force exerted.

관련 논문AI추천

Effectiveness of anchorage with temporary anchorage devices during anterior maxillary tooth retraction: A randomized clinical trialAlban Desoutter, Fatoumata Souaré, Frédéric Cuisinier, Stéphane Barthélemi대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제5호Does mini-implant-supported rapid maxillary expansion cause less root resorption than traditional approaches? A micro-computed tomography studyAlcin Rukiye, Malkoç Siddik대한치과교정학회 · 대한치과교정학회지2021 · 제51권 제4호Effects of orthodontic force on root surface damage caused by contact with temporary anchorage devices and on the repair processÖzge Çelik Güler, Sıddık Malkoç대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제2호Which anchorage device is the best during retraction of anterior teeth? An overview of systematic reviewsBearn David R., McIntyre Grant T., Nabbat Sarah A., Yassir Yassir A.대한치과교정학회 · 대한치과교정학회지2022 · 제52권 제3호Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position모성서, Jae-Won Song, Joong-Ki Lim, Kee-Joon Lee, Sang-Jin Sung, Youn-Sic Chun대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제4호Preliminary three-dimensional analysis of tooth movement and arch dimension change of the maxillary dentition in Class II division 1 malocclusion treated with first premolar extraction: conventional anchorage vs. mini-implant anchorage김병호, 박헌묵, 백승학, 양일형대한치과교정학회 · 대한치과교정학회지2012 · 제42권 제6호

이 간행물의 다른 논문 (7건)