본문 바로가기
KERD
논문KCI 등재

Effectiveness of anchorage with temporary anchorage devices during anterior maxillary tooth retraction: A randomized clinical trial

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: This study evaluated the efficiency of anchorage provided by temporary anchorage devices (TADs) in maxillary bicuspid extraction cases during retraction of the anterior teeth using a fixed appliance. Methods: Patients aged 12 to 50 years with malocclusion for which bilateral first or second maxillary bicuspid extractions were indicated were included in the study and randomly allocated to the TAD or control groups. Retraction of the anterior teeth was achieved using skeletal anchorage in the TAD group and conventional dental anchorage in the control group. A computed tomography (CT) scan was performed after alignment of teeth, and a second CT scan was performed at the end of extraction space closure in both groups. A three-dimensional superimposition was performed to visualize and quantify the maxillary first molar movement during the retraction phase, which was the primary outcome, and the stability of TAD movement, which served as the secondary outcome. Results: Thirty-four patients (17 in each group) underwent the final analysis. The two groups showed a significant difference in the movement of the first maxillary molars, with less significant anchorage loss in the TAD group than that in the control group. In addition, TAD movement showed only a slight mesial movement on the labial side. On the palatal side, the mesial TAD movement was greater. Conclusions: In comparison with conventional dental anchorage, TADs can be considered an efficient source of anchorage during retraction of maxillary anterior teeth. TADs remain stable when correctly placed in the bone during the anterior tooth retraction phase.

Abstract

Objective: This study evaluated the efficiency of anchorage provided by temporary anchorage devices (TADs) in maxillary bicuspid extraction cases during retraction of the anterior teeth using a fixed appliance. Methods: Patients aged 12 to 50 years with malocclusion for which bilateral first or second maxillary bicuspid extractions were indicated were included in the study and randomly allocated to the TAD or control groups. Retraction of the anterior teeth was achieved using skeletal anchorage in the TAD group and conventional dental anchorage in the control group. A computed tomography (CT) scan was performed after alignment of teeth, and a second CT scan was performed at the end of extraction space closure in both groups. A three-dimensional superimposition was performed to visualize and quantify the maxillary first molar movement during the retraction phase, which was the primary outcome, and the stability of TAD movement, which served as the secondary outcome. Results: Thirty-four patients (17 in each group) underwent the final analysis. The two groups showed a significant difference in the movement of the first maxillary molars, with less significant anchorage loss in the TAD group than that in the control group. In addition, TAD movement showed only a slight mesial movement on the labial side. On the palatal side, the mesial TAD movement was greater. Conclusions: In comparison with conventional dental anchorage, TADs can be considered an efficient source of anchorage during retraction of maxillary anterior teeth. TADs remain stable when correctly placed in the bone during the anterior tooth retraction phase.

참고문헌 (33)

  1. Gainsforth BL, "A study of orthodontic anchorage possibilities in basal bone", Am J Orthod Oral Surg, 31, pp.406~417 (1945)
  2. Linkow LI, "The endosseous blade implant and its use in orthodontics", Int J Orthod, 7, pp.149~154 (1969)
  3. Wehrbein H, "The orthosystem--a new implant system for orthodontic anchorage in the palate", J Orofac Orthop, 57, pp.142~153 (1996)
  4. Melsen B, "Zygoma ligatures : an alternative form of maxillary anchorage", J Clin Orthod, 32, pp.154~158 (1998)
  5. Park HS, "The skeletal cortical anchorage using titanium microscrew implants", Korean J Orthod, 29, pp.699~706 (1999)
  6. Lee JS, "Micro-implant anchorage for lingual treatment of a skeletal class II malocclusion", J Clin Orthod, 35, pp.643~647 (2001)
  7. Kyung HM, "Development of orthodontic micro-implants for intraoral anchorage", J Clin Orthod, 37, pp.321~328 (2003)
  8. Maino BG, "The spider screw for skeletal anchorage", J Clin Orthod, 37, pp.90~97 (2003)
  9. Park HS, "Group distal movement of teeth using microscrew implant anchorage", Angle Orthod, 75, pp.602~609 (2005)
  10. Benson PE, "Midpalatal implants vs headgear for orthodontic anchorage : a randomized clinical trial : cephalometric results", Am J Orthod Dentofacial Orthop, 132, pp.606~615 (2007)
  11. Upadhyay M, "Treatment effects of mini-implants for en-masse retraction of anterior teeth in bialveolar dental protrusion patients : a randomized controlled trial", Am J Orthod Dentofacial Orthop, 134, pp.18.e1~29.e1 (2008)
  12. Garfinkle JS, "Evaluation of orthodontic mini-implant anchorage in premolar extraction therapy in adolescents", Am J Orthod Dentofacial Orthop, 133, pp.642~653 (2008)
  13. Feldmann I, "Anchorage capacity of osseointegrated and conventional anchorage systems:a randomized controlled trial", Am J Orthod Dentofacial Orthop, 133, pp.339~352 (2008)
  14. Sharma M, "Mini-screw implant or transpalatal arch-mediated anchorage reinforcement during canine retraction : a randomized clinical trial", J Orthod, 39, pp.102~110 (2012)
  15. Sandler J, "Effectiveness of 3 methods of anchorage reinforcement for maximum anchorage in adolescents : a 3-arm multicenter randomized clinical trial", Am J Orthod Dentofacial Orthop, 146, pp.10~20 (2014)
  16. Miles PG, "Self-ligating vs conventional twin brackets during en-masse space closure with sliding mechanics", Am J Orthod Dentofacial Orthop, 132, pp.223~225 (2007)
  17. Wu TY, "Factors associated with the stability of mini-implants for orthodontic anchorage : a study of 414 samples in Taiwan", J Oral Maxillofac Surg, 67, pp.1595~1599 (2009)
  18. Dalessandri D, "Determinants for success rates of temporary anchorage devices in orthodontics : a meta-analysis(n > 50)", Eur J Orthod, 36, pp.303~313 (2014)
  19. Hsieh YD, "Evaluation on the movement of endosseous titanium implants under continuous orthodontic forces : an experimental study in the dog", Clin Oral Implants Res, 19, pp.618~623 (2008)
  20. Treil J, "Thearchitectural balance of the face : a 3D cephalometric concept", Rev Stomatol Chir Maxillofac, 100, pp.111~122 (1999)
  21. Liu YH, "Comparison of the differences in cephalometric parameters after active orthodontic treatment applying mini-screw implants or transpalatal arches in adult patients with bialveolar dental protrusion", J Oral Rehabil, 36, pp.687~695 (2009)
  22. Liu H, "Drift characteristics of miniscrews and molars for anchorage under orthodontic force : 3-dimensional computed tomography registration evaluation", Am J Orthod Dentofacial Orthop, 139, pp.e83~e89 (2011)
  23. Jambi S, "Reinforcement of anchorage during orthodontic brace treatment with implants or other surgical methods", Cochrane Database Syst Rev, (8), pp.CD005098~ (2014)
  24. Al-Sibaie S, "Assessment of changes following en-masse retraction with mini-implants anchorage compared to two-step retraction with conventional anchorage in patients with class II division 1 malocclusion: a randomized controlled trial", Eur J Orthod, 36, pp.275~283 (2014)
  25. Antoszewska-Smith J, "Effectiveness of orthodontic miniscrew implants in anchorage reinforcement during enmasse retraction : a systematic review and metaanalysis", Am J Orthod Dentofacial Orthop, 151, pp.440~455 (2017)
  26. Rizk MZ, "Effectiveness of en masse versus two-step retraction : a systematic review and meta-analysis", Prog Orthod, 18, pp.41~ (2018)
  27. Becker K, "Efficacy of orthodontic mini implants for en masse retraction in the maxilla : a systematic review and meta-analysis", Int J Implant Dent, 4, pp.35~ (2018)
  28. Pervin S, "En masse versus twostep retraction of the anterior segment", Evid Based Dent, 19, pp.111~112 (2018)
  29. Alharbi F, "Anchorage effectiveness of orthodontic miniscrews compared to headgear and transpalatal arches : a systematic review and meta-analysis", Acta Odontol Scand, 77, pp.88~98 (2019)
  30. Schätzle M, "Survival and failure rates of orthodontic temporary anchorage devices : a systematic review", Clin Oral Implants Res, 20, pp.1351~1359 (2009)
  31. Aly SA, "Success rates and factors associated with failure of temporary anchorage devices : a prospective clinical trial", J Investig Clin Dent, 9, pp.e12331~ (2018)
  32. Liou EJ, "Do miniscrews remain stationary under orthodontic forces", Am J Orthod Dentofacial Orthop, 126, pp.42~47 (2004)
  33. Büchter A, "Load-related bone modelling at the interface of orthodontic microimplants", Clin Oral Implants Res, 17, pp.714~722 (2006)

관련 논문AI추천

Which anchorage device is the best during retraction of anterior teeth? An overview of systematic reviewsBearn David R., McIntyre Grant T., Nabbat Sarah A., Yassir Yassir A.대한치과교정학회 · 대한치과교정학회지2022 · 제52권 제3호Combined anterior and posterior miniscrews increase apical root resorption of maxillary incisors in protrusion and premolar extraction casesDong Wu, Ehab A. Abdulghani, Li Mei, Wei Zheng, Yuan Li, Yue Zhou, Yu Li, Zhenxing Tang, Zhizun Wang대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제1호Preliminary three-dimensional analysis of tooth movement and arch dimension change of the maxillary dentition in Class II division 1 malocclusion treated with first premolar extraction: conventional anchorage vs. mini-implant anchorage김병호, 박헌묵, 백승학, 양일형대한치과교정학회 · 대한치과교정학회지2012 · 제42권 제6호En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding국윤아, 김성훈, 안효원, 정규림, Gerald Nelson, Jeong-Hyun Jee, Kyung-Won Seo대한치과교정학회 · 대한치과교정학회지2014 · 제44권 제5호Effects of orthodontic force on root surface damage caused by contact with temporary anchorage devices and on the repair processÖzge Çelik Güler, Sıddık Malkoç대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제2호Effectiveness of en-masse retraction using midpalatal miniscrews and a modified transpalatal arch: Treatment duration and dentoskeletal changesJungkil Lee, Ken Miyazawa, Masako Tabuchi, Misuzu Kawaguchi, Shigemi Goto, Takuma Sato대한치과교정학회 · 대한치과교정학회지2014 · 제44권 제2호

이 간행물의 다른 논문 (7건)