The current study had the radiation workers working in nuclear medicine department wear individual exposure dosimeters in the front and in the back, considering the underestimated individual exposure to radiation from patients undergoing radiological medicine treatment. The utility of the device was assessed in the study. From January 2015 to February 2015, 85 radiation workers working in 11 Korean nuclear medicine department were analyzed by their workplace and their specialty; PET-CT and gamma cameras were used to analyze the radiation exposure in the front and the back of the radiation workers. This revealed that the exposure measurement and assessment using the dosimeter worn on the front were not underestimated. However, because this measurement did not take into account the adequate radiation weighting factor for the back side dosimeter, a radiation exposure assessment algorithm for the back side radiation exposure must be developed, which can be used as a basic data for introducing double dosimeter for radiation workers working in nuclear medicine department.
Abstract
The current study had the radiation workers working in nuclear medicine department wear individual exposure dosimeters in the front and in the back, considering the underestimated individual exposure to radiation from patients undergoing radiological medicine treatment. The utility of the device was assessed in the study. From January 2015 to February 2015, 85 radiation workers working in 11 Korean nuclear medicine department were analyzed by their workplace and their specialty; PET-CT and gamma cameras were used to analyze the radiation exposure in the front and the back of the radiation workers. This revealed that the exposure measurement and assessment using the dosimeter worn on the front were not underestimated. However, because this measurement did not take into account the adequate radiation weighting factor for the back side dosimeter, a radiation exposure assessment algorithm for the back side radiation exposure must be developed, which can be used as a basic data for introducing double dosimeter for radiation workers working in nuclear medicine department.
참고문헌 (9)
- 박준철, "핵의학 종사자에서 손 부위의 외부 피폭선량 연구", 방사선기술과학, 35(2), pp.141~149 (2012), 대한방사선과학회[DOI]
- International Commission on Radiological Protection, "ICRP 60. Pergamon Press : 1990 Recommendations of the International Commission on Radiological protection", ~ (1991)
- "ICRP Publication 60 : Recommendations of the International Commission on Radiological protection", ~ (1990)
- 이계곤, "방사선사의 직무만족도에 관한 연구 : 전라북도에 근무하는 방사선사", 석사, ?, pp.2001
- Chun Goo Kang, "A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by job", Journal of Nuclear Medicine Technology, 14(2), pp.9~16 (2010)
- G. Cabral, A, "Investigation of maximum doses absorbed by people accompanying patients in nuclear medicine departments", Radiation protection dosimetry, 101(1), pp.435~438 (2002)
- Bong Sik Lim, "Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea", Jounal of Radiological Science and Technology, 29(3), pp.185~195 (2006)
- 임창선, "핵의학과에서 방사선 피폭관리 실태에 대한 조사 연구", 한국산학기술학회논문지, 10(7), pp.1760~1765 (2009), 한국산학기술학회
- 강보선, "핵의학과에서 환경방사선량 측정에 대한 연구", 한국산학기술학회논문지, 11(6), pp.2118~2123 (2010), 한국산학기술학회