본문 바로가기
KERD
논문KCI 등재

핵의학 방사선작업종사자의 수정체선량 평가

Evaluation of Lens Dose of Nuclear Medicine Radiation Workers

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

In April 2011, ICRP issued a statement on tissue reactions in which it recommended, for occupational exposure, a dose limit for equivalent dose to the lens of the eye of 20 mSv·year-1, averaged over defined periods of 5 years, with no annual dose in a single year exceeding 50 mSv. Thus, the need for lens dose assessment and management of nuclear medicine workers is increasing. This study measured the lens exposure dose of the nuclear medicine radiation workers using ED 3 Active Extremity Dosimeter for six months from February 2017 to July 2017. It was measured for 99mTc-Bone scan and 18F-FDG PET. because they are most frequently exam in nuclear medicine. As a result of measurement, the annual lens dose in 99mTc-Bone scan is 4.29±1.73 mSv·day-1, based on 8.37±2.82 patients·day-1. The annual lens dose in 18F-FDG PET is 2.56±0.98 mSv·day-1, based on 5.47±1.48 patients·day-1. This does not exceed the lens equivalent dose limit. However, it is necessary to continuously manage the lens dose as it may result in workers exposed to high doses depending on the working environment.

Abstract

In April 2011, ICRP issued a statement on tissue reactions in which it recommended, for occupational exposure, a dose limit for equivalent dose to the lens of the eye of 20 mSv·year-1, averaged over defined periods of 5 years, with no annual dose in a single year exceeding 50 mSv. Thus, the need for lens dose assessment and management of nuclear medicine workers is increasing. This study measured the lens exposure dose of the nuclear medicine radiation workers using ED 3 Active Extremity Dosimeter for six months from February 2017 to July 2017. It was measured for 99mTc-Bone scan and 18F-FDG PET. because they are most frequently exam in nuclear medicine. As a result of measurement, the annual lens dose in 99mTc-Bone scan is 4.29±1.73 mSv·day-1, based on 8.37±2.82 patients·day-1. The annual lens dose in 18F-FDG PET is 2.56±0.98 mSv·day-1, based on 5.47±1.48 patients·day-1. This does not exceed the lens equivalent dose limit. However, it is necessary to continuously manage the lens dose as it may result in workers exposed to high doses depending on the working environment.

참고문헌 (16)

  1. 2014년 전국 인력 RI 장비 현황 합계, "대한핵의학회", ~ (2014)
  2. 대한핵의학회, "2014년 전국 PET 검사 및 대수", ~ (2014)
  3. 원자력안전위원회, "개인 피폭방사선량의 평가 및 관리에 관한 규정", 원자력안전위원회고시 제2014-69호, ~ (2014)
  4. 원자력안전위원회, "원자력안전법 시행령 대통령령 제27678호", ~ (2016)
  5. Establishment of Dose Constrains for Radiation Workers in Nuclear Medicine, "원자력안전위원회", ~, pp.NSTAR-15NS11-01 (2016)
  6. 한국동위원소협회, "방사성동위원소 핵종정보", ~ (2010)
  7. Behrens R, "Monitoring the eye lens: which dose quantity is adequate?", Phys. Med. Biol, 55(14), pp.4047~4062 (2010)
  8. 조정근, "안와 및 안부속기 종양의 방사선치료에서 백내장의 예방을 위한 렌즈보호 장치의 효용성", 한국콘텐츠학회 논문지, 7(12), pp.139~144 (2007), 한국콘텐츠학회
  9. ICRP, "1990 Recommendations of the International Commission on Radiological Protection" (1990), Pergamon Press
  10. ICRP, "The 2007 Recommendations of the International Commission on Radiological Protection" (2007), Pergamon Press
  11. ICRP, "ICRP Statement on Tissue Reaction and Early and Late Effects of Radiation in Normal Tissues and Organs-Threshold Doses for Tissue Reactions in a Radiation Protection Context" (2012), Pergamon Press
  12. Quantities and units in radiation protection dosimetry, "ICRU", ICRU, ~, pp.ICRU Report 51 (1993)
  13. 주용진, "핵의학과 주사와 분배업무 작업종사자 및 수시출입자 피폭선량연구", 방사선산업학회지, 11(1), pp.47~54 (2017), (사)한국방사선산업학회
  14. 김희근, "방사성물질과 접촉하는 작업의 손 · 발이 받는 피폭방사선량 평가에 대한 고찰", 방사선산업학회지, 11(3), pp.123~130 (2017), (사)한국방사선산업학회
  15. 송하진, "ED3를 이용한 방사성동위원소 의약품의 수정체 피폭선량평가", 방사선산업학회지, 11(1), pp.19~25 (2017), (사)한국방사선산업학회
  16. Yokoyama S, "Calculation of equivalent dose for the lens of the eye in a positron field using EGS5", Prog. Nucl. Sci. Technol, 4, pp.788~792 (2014)

관련 논문AI추천

이 간행물의 다른 논문 (12건)